{"product_id":"1-phase-buck-boost-step-down-transformer-240v-primary-220v-secondary-45-87-amps-50-60hz","title":"1-Phase Buck\/Boost Step-Down Transformer - 240V Primary - 220V Secondary - 45.87 Amps - 50\/60Hz","description":"\u003cp\u003eSpecifications \/ Additional Information\u003cbr\u003eMT-BBT-240V-220V-45.87A Buck and Boost Step-Down Transformer     Ratings\u003cbr\u003eTransformer Type: Buck\/Boost Step-Down Autotransformer     UL Listed for United States\u003cbr\u003ePhase: Single Phase     CSA Certified for Canada\u003cbr\u003eFrequency: 50\/60 Hz     NEMA 3R Indoor\/Outdoor Enclosure\u003cbr\u003eInput Voltage: 240 V     Meets or Exceeds NEMA ST-20 Standards\u003cbr\u003ePrimary Amps: 41.67 A @ 240 V     Buck and Boost Step-Down Transformer\u003cbr\u003ePrimary Configuration: Two Winding     \u003cbr\u003ekVA: 10     \u003cbr\u003eOutput Voltage: 220 V     \u003cbr\u003eSecondary Amps: 45.87 A @ 220 V     \u003cbr\u003eVoltage Difference: 92%     \u003cbr\u003eWinding Material: Aluminum     \u003cbr\u003eKnockouts: Side and Rear     \u003cbr\u003ePrimary Termination: Front Access Copper Tabs or Lead Wires     \u003cbr\u003eSecondary Termination: Front Access Copper Tabs or Lead Wires     \u003cbr\u003eCooling: Air \/ Dry Type     \u003cbr\u003eInsulation: 180°C     \u003cbr\u003eTemperature Rise: 150°C     \u003cbr\u003eSound Level: 36 dB     \u003cbr\u003eEnclosure Rating: NEMA 3R     \u003cbr\u003eEncapsulation: Silica Sand \u0026amp; Resin Compounds     \u003cbr\u003eEnclosure Material: Steel     \u003cbr\u003eFinish: ANSI 61 Grey \/ UL50     \u003cbr\u003eDimensions: 10\"H x 4.08\"W x 3.88\"D     Intl: 1-903-270-1187\u003cbr\u003eWeight: 25 lb\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e1-Phase Buck\/Boost Step-Down Transformer - 240V Primary - 220V Secondary - 45.87 Amps - 50\/60Hz\u003c\/p\u003e\n\u003cp\u003eThe MT-BBT-240V-220V-45.87A Single Phase Step-Down Buck and Boost Transformer from Larson Electronics is powerful, reliable, and designed with the environment in mind. Suitable for both indoor and outdoor applications, the MT-BBT-240V-220V-45.87A provides increased reliability, higher efficiency, protection against critical equipment failures and an extra level of protection by isolating the power source from the connected device. The lower operating costs, lower heat emissions and lower cost of ownership make this transformer ideal for a wide range of applications and businesses.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTransformer Features\u003c\/strong\u003e: The MT-BBT-240V-220V-45.87A buck and boost transformer is a single phase unit with a 10 kVA rating and a primary voltage of 240 V using a maximum of 41.67 amps on the primary side. This step-down transformer has a secondary voltage of 220 V and provides up to 45.87 amps available on the secondary side. Featuring robust construction, this unit`s cores are manufactured with non-aging, cold-rolled silicon steel laminations using state of the art technology.\u003c\/p\u003e\n\u003cp\u003eThis unit boasts a low cost of ownership and is highly energy efficient. Lower heat emissions mean less cooling is needed as well. The NEMA 3R painted steel enclosure makes the unit suitable for both indoor and outdoor applications, and this step-down transformer can be either floor or wall mounted. The MT-BBT-240V-220V-45.87A features a 180°C insulation with a 150°C temperature rise.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e: The aluminum winding in the MT-BBT-240V-220V-45.87A are formed from high quality aluminum wire help to improve performance. The close tolerances used during manufacturing also eliminates burrs which hinder performance. Each core is specially coated to prevent the ingress of moisture and are electrically balanced to minimize axial forces during short circuit situations. Buck and boost transformers are designed to maximize the performance and life of electrical equipment. The MT-BBT-240V-220V-45.87A is encapsulated in silica sand and resin, and cased in a NEMA 3R steel enclosure. NEMA 4, NEMA 4X, and NEMA 12 enclosures are available upon request.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e: The MT-BBT-240V-220V-45.87A buck\/boost step-down transformer offers many benefits to the consumer. Buck\/boost transformers pass the majority of the load voltage directly through the transformer, only transforming a small percentage of the load. Due to this technology, a smaller and quieter step-down transformer is manufactured and uses less materials. This provides owners with significant energy savings as well as offering environmental benefits.\u003c\/p\u003e\n\u003cp\u003eHigher efficiency not only extends the life of the transformer, but also turn into cost savings for owners in the form of lower energy bills and decreased cost of ownership. Installation and maintenance costs are reduced due to the smaller form factor, and less overall space requirements are decreased. In addition, these step-down transformers operate quieter than a standard autotransformer of the same capacity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e: Integrated wall mounting brackets make installation fast and easy. Because of the smaller overall footprint, heavy machinery is rarely needed for mounting and installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e: Installation is simple. Connect the primary leads and secondary leads to the step-down transformer per the provided wiring diagram. Knockout hubs on either side and the bottom of the transformer allow for easy line-in and line-out wiring. The front access cover provides convenient .\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e: Air conditioners, lighting systems, heating elements, motor applications and other applications that that require the ability to power loads that differ from the available line voltage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLimitations\u003c\/strong\u003e: While there are many benefits to a buck\/boost transformer, there are some limitations to consider. This transformer will only transformer voltage, it will not convert phases, it will not create even legs between line 1 and line 2 (L1 and L2 WILL be UNEVEN), has no circuit isolation, and does not create a neutral for applications where a neutral is not already present.\u003c\/p\u003e","brand":"LARSON ELECTRONICS","offers":[{"title":"Default Title","offer_id":48502392652025,"sku":"PL3-MT-BBT-240V-220V-45.87A","price":2351.6,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0526\/9553\/1701\/files\/WhatsAppImage2026-06-09at06.57.35.jpg?v=1780970359","url":"https:\/\/shoppurilite.ca\/fr\/products\/1-phase-buck-boost-step-down-transformer-240v-primary-220v-secondary-45-87-amps-50-60hz","provider":"PuriLite","version":"1.0","type":"link"}