FRL-EMY-18-100W-FUVC-KT-120V UVC Sanitation Lamp w/ Ballast - Ozone Free Ratings/Features
Lamp Technology: Far UV-C Excimer 222nm Germicidal Light
Dimensions: 18"-L x 1.85"-OD (Glass OD: 1.58") Kills 99% of Viruses and Other Germs
Weight: < 1 lb Mercury Free Lamp
Ballast Dimension: - Instant-On Lamp, No Warm Up Time
Ballast Weight: - More Efficient & Effective than UVC Lamps
Voltage: Ballast Dependent (Ballast Included) No Harmful UVC Emissions
Frequency: Ballast Dependent (Ballast Included) No Block Off/Bandpass/Cutoff Filters) Needed
Total Watts: 100W Skin Safe & Eye Safe
Total UV Output: - Ozone Free
Effective UV Intensity: 5500 uW/cm2 @ lamp lens Low Heat Output
Expected Lifespan: 6,500+ Hours EPA Reg. No 98409-1
UV Wavelength: Far UV-C, 222nm EPA Est. No. 98409-TX-1
Lamp Type: Excimer
Lamp Base: -
Replacement Lamp: FRL-EMY-18-100W-FUVC
Replacement Ballast: FRL-EMY-18-100W-FUVC-RBALL
Lamp Mounting Bracket: FRL-EMY-XX-FUVC-SP0118-R4
Beam Angle: 360º
Light Configuration: Flood
Remote Driver: Included
Ballast/Power Supply Voltage: 120 V AC, 50/60 Hz
Amps: -  
Ambient Operating Temp Range: -50°C to +80°C Special Orders - Requirements
Materials: KrCl Gas Mixture, Polymer End Caps, Glass Lens
Lens Material: Quartz Glass
Mounting: End Cap Lamp Clips (Hardware not included)
Wiring: +/- Pigtails
Cord Cap: -
***PLEASE NOTE: UV-C light can cause temporary or permanent loss of vision, and temporary acute redness or ulceration (mild to severe sunburn) to exposed skin. To prevent exposure, do not operate the device in any application that allows UV-C light to be visible during operation. NEVER LOOK DIRECTLY AT THE BULB OR DISINFECTING TARGET ZONE. DO NOT touch bulb with bare hands. The oils in your skin will damage the lamp. Fingerprints will result in reduced performance and significantly reduce the lifespan of the lamp unless they are removed with alcohol. Please read instruction manual for UV safety requirements before operating.***
' Product Overview '
function MM_openBrWindow(theURL,winName,features) { //v2.0 window.open(theURL,winName,features); }
The FRL-EMY-18-100W-FUVC-KT-120V from Larson Electronics is a UV Excimer Light that can disinfect 99% of viruses, bacteria, mold, and spores in facilities and on surfaces. This ozone-free unit offers 222nm UV-C output and comes with a ballast. Considered to be eye and skin safe, the far-UV lamp offers instant start and cool operation. The ballast/power supply, which operates on 120 V AC, 50/60 Hz, is included with the lamp. *Please note: This product produces UV light. Make sure to follow all safety guidelines and protocols found in the user manual. UVC light in the proper setting kills up to 99.9% of viruses, mold, spores, and bacteria. * The FRL-EMY-18-100W-FUVC-KT-120V is a powerful sanitation solution that has eye and skin safe features for industrial sites and commercial facilities. This 100-watt excimer lamp offers 5500 uW/cm2 UV intensity at 222nm UV wavelength. The ozone-free light has an expected lifespan of 10,000+ hours and emits a flood beam pattern with 360 degrees of coverage. This UV light is protected by a quartz glass. The far-UV light can disinfect over 99% of viruses, bacteria, mold, and spores. Adhering closely to recommended exposure time for viruses, multiple lights can be purchased to cover larger areas quicker. This lamp is considered to be eye and skin safe (the 222nm UV wavelength cannot penetrate the eyes and skin of humans), making applications suitable in occupied areas requiring sanitation. Designed for cool operation, the instant-start light is efficient at eliminating harmful microbes, viruses, and bacteria at low doses. Benefits of Excimer Far UV Lamps: When it comes to Far-UV lamps, there are few options in the skin-safe and eye-safe wavelengths. Similar to LED lamps, excimer lamps provide “instant-on” startup, and do not require a warmup period; excimer lamps are at 100% peak output when switched on. Most lamp technologies that do product UVC use mercury in the manufacturing process. Excimer lamps have ZERO mercury, making them more environmentally friendly. Excimer lamps can be tuned to specific wavelengths (222nm wavelength for this product) and produce no harmful UVC radiation or wasteful visible light and infrared light. Excimer lamps are more efficient at converting electricity (input power) into UV irradiance, which reduces the heat output from excimer lamps over other technologies. Fluorescent, amalgam, low-pressure mercury, and high-pressure mercury lamps do not product as tight of a wavelength and generate more heat, both of which wastes energy for the UV sanitation application. Excimer lamps have a higher average UV irradiance per square inch and have a higher photon emission over other lamp technologies. Being safe for use in occupied areas, instant-on power, mercury free, higher UV output, and low heat output make Far-UV excimer lamps the preferred choice for UV sanitation and disinfecting applications. Voltage: The FRL-EMY-18-100W-FUVC-KT-120V is compatible with 120 V AC, 50/60 Hz. Cooled by natural air, the ballast is included with the far-UV lamp. We also offer 208V, 220V, 240V, 277V, 347V, and 480V AC models, and 12V, 24V, 48V, 125V, and 250V DC models upon request. Wiring: The FRL-EMY-18-100W-FUVC-KT-120V is designed for hard wire applications and includes flying leads for power connections to the remote mounted ballast. We can provide corded models with factory installed cord and cord cap upon request. Mount: Mounting brackets for the FRL-EMY-18-100W-FUVC-KT-120V are available but are sold separately. The compatible mounting brackets can be found here: . Note on Environment: Sunlight and visible light fixtures do not impact the effectiveness of the disinfecting on this UVC sanitation product. Metal halide, high pressure sodium, fluorescent, and LED light fixtures can be left on. The UV radiation emitted from this product is not disrupted by any type of lighting in the environment. Put simply, NO it DOES NOT need to be dark in the area you plan to disinfect. The UV radiation is harmful to the eyes and skin, and that is why you should not be in the area while it is in operation. Please see user manual for additional safety information. Suggested Applications: Sanitation, disinfection, commercial locations, industrial parks, medical centers, labs, manufacturing and semiconductors; kills 99% of viruses, bacteria, mold, and spores.

Shipping and delivery Information

Payment

American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

You may also like

Recently viewed