Description
Specifications / Additional Information
This unit is Made In USA - Manufactured in Texas
HAL-TBL-BX-AEP.Z-18.18.30-5XH-WC-25C-120V-EPP Hazardous Location Single-door UV Cabinet | Ratings/Features |
Lamp Technology: UV-C Fluorescent | Listed for Use in United States & Canada |
Lamp Qty: (20) 18" UV Lamps - (4) UV Lamps per Shelf | Class I, Division 2, Groups A, B, C, D |
Shelf Dimensions: (5) 18" x 18" Mesh Wire Shelves | Class I, Zone 2, Groups IIA, IIB and IIC |
Shelve Clearance: 6" | NRTL Listed to NFPA 496 |
Weight: 145 lbs | NRTL Listed to UL 508A |
Voltage: 120 V, 60 Hz | NRTL Listed to CSA C22.2 No. 14 |
Total Watts: - | Short-wave Germicidal Light |
Single-lamp Watts: - | Kills 99% of Viruses and Other Germs |
Total UV Output: - | EPA Reg. No 98409-1 |
Single-lamp UV Output: - | EPA Est. No. 98409-TX-1 |
Expected Lifespan: 8,000+ Hours | |
UV Wavelength: UV-C, 200nm - 280nm (253.7 nm) | |
Lamp Type: - | |
Lamp Base: - | |
Replacement Lamp: - | |
Beam Angle: 360º | |
Light Configuration: Flood | |
Surface Reflectance: Stainless Steel Interior Finish | |
Timer: Adjustable Internal Timer, 5-minute Factory Setting | |
Activation: Push Button |  |
Safety: Yellow Indicator Light and Safety Kill Switch on Door |  |
Amps: - |  |
Minimum Airflow Requirement: 80 PSI |  |
Maximum Airflow Requirement: 120 PSI |  |
Ambient Operating Temp Range: - | Special Orders - Requirements |
Materials: - | |
Lens Material: - | |
Mounting: Mobile Flat Base w/ Handle and (2) 8" Swivel-locking Casters [Front], (2) 8" Stationary Casters [Back] | |
Wiring: 25' 16/3 SOOW Cord w/ Explosion Proof Cord Cap | |
Cord Cap: 5-15 Straight Blade or 5-20 Straight Blade | |
***PLEASE NOTE: UV-C light can cause temporary or permanent loss of vision, and temporary acute redness or ulceration (mild to severe sunburn) to exposed skin. To prevent exposure, do not operate the device in any application that allows UV-C light to be visible during operation. NEVER LOOK DIRECTLY AT THE BULB OR DISINFECTING TARGET ZONE. DO NOT touch bulb with bare hands. The oils in your skin will damage the lamp. Fingerprints will result in reduced performance and significantly reduce the lifespan of the lamp unless they are removed with alcohol. Please read instruction manual for UV safety requirements before operating.*** |
function MM_openBrWindow(theURL,winName,features) { //v2.0
window.open(theURL,winName,features);
}
This unit is Made In USA - Manufactured in Texas
The HAL-TBL-BX-AEP.Z-18.18.30-5XH-WC-25C-120V-EPP from Larson Electronics is a Hazardous Location Mobile UV Disinfection Cabinet that uses a Type Z continuous flow purge system and is for cleaning several handheld devices quickly and simultaneously. Equipped with twenty 18" UV lamps, the unit offers UV-C output at a range of 200nm - 280nm (253.7nm). There are five 18" x 18" mesh wire shelves for holding different types of equipment. The single-door UV oven has highly visible indicator lights for safe operation and comes with an internal timer. The disinfection cabinet contains four 8" casters at the bottom of the unit.
*Please note: This product produces UV light. Make sure to follow all safety guidelines and protocols found in the user manual. UVC light in the proper setting kills up to 99.9% of viruses, mold, spores, and bacteria. *
The HAL-TBL-BX-AEP.Z-18.18.30-5XH-WC-25C-120V-EPP is a powerful sanitation solution for cleaning compact and handheld equipment in busy work sites. This UV oven is safe to use in Class I Division 2 hazardous location. Equipped with twenty 18" UVC fluorescent lamps, this system offers UV output, within the 200nm - 280nm UV-C range (253.7 nm). The lights have an expected lifespan of 8,000+ hours and emit a flood beam pattern with 360 degrees of coverage. A stainless steel interior finish promotes UV light distribution. Inside the box, there are five 18" x 18" mesh wire shelves with 6" clearance for holding different types of devices for sanitation. Each shelf has four lamps on every wall including the door to ensures maximum exposure.
This hazardous location UV cabinet turns off automatically when the door is open. A yellow indicator light turns on when the unit is in use to safely notify the operator about ongoing sanitation. With a recommended 5-minute exposure time at full capacity, multiple UV boxes can be purchased to clean several devices at the same time. Operators may access an external timer (set at 5 minutes from the factory) on the box to ensure the recommended duration of exposure is met every session. The UV light can disinfect over 99% of bacteria, viruses, mold, and spores.
Voltage: The HAL-TBL-BX-AEP.Z-18.18.30-5XH-WC-25C-120V-EPP operates on 120 V AC, 60 Hz.
Purge and Pressurization System: The HAL-TBL-BX-AEP.Z-18.18.30-5XH-WC-25C-120V-EPP uses a Type Z continuous flow purge and pressurization system that makes it safe to use within Class I Division 2 hazardous locations. In a purge and pressurization system, any hazardous gas is purged from the enclosure through a series of complete air exchanges. The enclosure is then pressurized to prevent the entry of any hazardous gas or dust from entering the enclosure. In a continuous flow purge system, like the one used in this UV oven, a constant flow of air following the purge is used to maintain internal pressure.
The HAL-TBL-BX-AEP.Z-18.18.30-5XH-WC-25C-120V-EPP features a Type Z continuous flow purge system. A Type Z system requires a minimum of 25 Pa for internal pressure. The other main feature of a Type Z system is that power to the unit is automatically disconnected if a drop in pressure below the minimum occurs or any other loss of pressure occurs. This means that it then must go through the purge and pressurization process successfully again before operation can resume within the hazardous area.
Operation: The HAL-TBL-BX-AEP.Z-18.18.30-5XH-WC-25C-120V-EPP is equipped with a C1D1 rated push button for power and a C1D1 rated power indicator light on the outside of the unit. A timer is installed on the inside of the enclosure. The timer keeps the UV lamps running for the recommended amount of time to disinfect the desired items.
To use the UV oven, the operator places the items in the racks on the inside of the oven, closes the gasketed door, secures the stainless steel draw latches, and pushes the power button. The unit then purges the enclosure and pressurizes it. Once pressurization is complete, power is provided to the timer. The UV lamps then power up and stay on throughout disinfection. This entire process must be repeated every time the lid is opened or pressure is otherwise lost.
|
Shipping and delivery Information
The PuriLite Peace of Mind 30-day money back guarantee
Payment
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
You may also like
Save 26%


ROXON
ROXON 860 CFM Centrifugal Blower type motor (High Grade) 30 Inches Under Cabinet Range Hood Kitchen Exhaust Fan Stainless Steel RXN-U15BS-30
Sale price$589.99
Regular price$799.99
Save 13%


Global Industrial
Global Industrial™ Network Server Data Rack Enclosure Cabinet, Vented Doors, 37U, Unassembled
Sale price$3,489.99
Regular price$3,999.99
Save 13%


Commercial Chef
Commercial Chef CHM990W 900 Watt Counter Top Microwave Oven, 0.9 Cubic Feet, White Cabinet
Sale price$269.99
Regular price$309.99
Save 21%


Interion
Interion® 2 Drawer Premium Lateral File Cabinet, Legal & Letter Size, 36"W x 18"D x 28"H, Putty
Sale price$1,189.99
Regular price$1,499.99
Save 21%


Global Industrial
Global Industrial™ Wardrobe Cabinet Easy Assembly 36x18x72 Tan
Sale price$1,189.99
Regular price$1,499.99
Save 13%


Interion
Interion® Premium Lateral File Cabinet, 5 Drawers, 30"W x 18"D x 64-1/2"H, Black
Sale price$2,179.99
Regular price$2,499.99