Class 1 Division 2 Fluorescent Light -2 Foot - Corrosion Resistant Requirements (Saltwater)

LARSON ELECTRONICSSKU: PL3-HALP-24-2L
filler

Price:
Sale price$526.00

Description

Specifications / Additional Information
HALP-24-3L Hazardous Area U.L. Ratings
UL Listings: United States - Canada Class I Division 2, Groups A, B, C, D
Dimensions: L-25.88” x W-7.21” x H-5.43” Class II, Division 2, Groups F, G
Weight: 12.5 Lbs UL 844
Total Watts: 72watts* UL 1598A Marine Type (Salt water)
Voltage: 120-277 AC 50/60Hz  California Title 24 Compliant
Total Lumens: T5-HO Bulbs 6,600 cUL Listed for Canada 
Lamp Life Expectancy: T5-HO Bulbs 20,000 Hours Meets USCG Specs
Efficiency: T5-HO Bulbs  91 Lumens per Watt T4 Temperature Rating
Operating Temp Range: T4A Rated -20 C to +70 C
Minimum Operating Temp: -20 C  
Maximum Case Temp: 70 C  
Beam Angle: N/A
Color Temp: 5,000k- T5-HO Bulbs 
Surface Mounting:  (2) aluminum flange brackets
Pendant Mounting: (2) 1/2" or 3/4" hubs  on either side of fixture Intl: 1-214-616-6180
Wiring Hub: 1/2" or 3/4" threaded NPT hubs  Fax: 1-903-498-3364
U.L Approval:   E-mail: 
Meets US Coast Guard specifications.
*Wattage totals are lamps only and may vary with different lamps.
' Product Overview '
Made in the USA The Larson Electronics HALP-24-2L Hazardous Area Fluorescent Light Fixture is U.S./ Canada UL Listed Class 1 Division 2 Groups A, B, C and D - UL 1598A listed, has a T4A temperature rating and is specifically designed to handle the rigors of wet and corrosive marine environments. The HALP-24-3L hazardous area fluorescent light fixture is designed for use in wet areas and saltwater-marine environments where corrosion resistance is critical to equipment longevity and safety. This Class 1 Division 2 rated fixture is constructed of non-corrosive materials including a polyester housing reinforced with glass fiber, a poured in gasket for reliable sealing and an impact resistant acrylic diffuser. Corrosion resistant plastic latches secure the lamp cover to the housing and provide a firm lock against the poured in seal to prevent drips and water intrusion. This fixture is UL 844 rated and Class 1 Division II, Groups A, B, C, D approved. The HALP-24-3L also carries a UL 1598A outdoor marine rating and meets US Coast Guard specifications. This lamp ideal for hazardous areas where corrosion resistance is mandatory and space limitations require a compact lighting solution.
HALP-24-2L Surface Mount HALP-24-2L HALP-24-2L Pendant Mount
HALP-24-2L with T8 lamps    HALP-24-2L with T5HO lamps
  Click Photo to Enlarge
NOTE ON LAMPS: This fixture comes equipped with-T5/HO – 24 Watt lamps producing2,500 lumens per bulb, a 5000 Kelvin color and a 20,000 hour rated service life. We offer -T12/HO –2025 lumens per bulb, 12,000 hours life, 4100 Kelvin color and T8/ – 1500 lumens per bulb, 24,000 hours life, 4100 Kelvin color tubes as lamp options for this fixture. The HALP-24-3L has an electronic universal voltage ballast that works on 120-277 AC 50/60Hz  Surface Mounting: Flange type aluminum mounts attached at each end of the fixture enables it to be simply secured to any surface. The mounts provide some shock absorbency protection while enabling the user to simply mount the fixture with the through-hole taps that protrude on each side of the fixture. The mounting holes are 14.91" inches on center apart along the top of this hazardous location light. The mounting holes are 9.5" inches on center across the top of the light.   Pendant Mounting: This light fixture can hang from the ceiling suspected by rigid pipe. Each fixture is equipped with either two 1/2" or 3/4" NPT hubs on either side of the  fixture. Operators will bring rigid pipe down to the threaded mounting ups. The wiring is fed down through the rigid pipe to one of the NPT hubs and tied to the fixture`s lead wires to complete the electrical connection. The remaining pendant hub provides support for the opposite end of the fixture.  Suggested Applications: The HALP-24-2L is designed for marine wet and damp locations, where corrosion resistant fluorescent lights are required. This includes petrochemical facilities, lubrication pits, oil drilling rigs, crew quarters, solvent/cleaning areas, water treatment areas, processing plants and marine loading docks.
Made in USA Quality Lamp Options
1. Each unit dialectically tested. 2. Fixture arrives assembled and lamped to reduce installation time and cost. Flange type stainless steel mounts attached at each end of the fixture enables it to be simply secured to any surface. 3. Fixture housing constructed of glass fiber reinforced polyester. 4. Relamping done via 6 stainless steel snap locking latches, which enable the operator to remove the door and access the lamps. 5. Lamp cover-diffuser constructed of high impact acrylic for corrosion resistance and lamp protection. 6. 1/2" or 3/4", threaded access hole for wiring conduit. T5/HO – 2500 lumens per bulb, 20,000 hours life, 5000 Kelvin color T12/HO--2025 lumens per bulb, 12,000 hours life, 4100 Kelvin color T8– 1500 lumens per bulb, 24,000 hours life, 4100 Kelvin color