Description
CyberPower PDU30SWHVT19ATNET Switched ATS PDU 200-240V 30A 2U 19-Outlets (2) L6-30P - Switched Auto Transfer Switch - NEMA L6-30P - 16 x IEC 60320 C13, 2 x IEC 60320 C19, 1 x NEMA L6-30R - 230 V AC - 2U - Rack-mountable
The CyberPower PDU30SWHVT19ATNET, a 19-outlet (rear), 2U rackmount switched automatic transfer switch (ATS) power distribution unit (PDU), provides 200-240V 30A output. It distributes unfiltered electrical pass-through to to 19 receptacles--16 IEC-320 C13, 2 IEC-320 C19, and 1 NEMA L6-30R receptacles-from redundant NEMA L6-30P plugs. Dual power cords can be plugged into separate power sources to provide redundancy to single-corded connected equipment. If power for the primary source exceeds the lower or upper thresholds, or if power fails, the PDU will switch to the secondary power source to ensure continuous operation. The PDU will switch back to the primary power source when incoming power becomes stable.
The PDU30SWHVT19ATNET includes a SNMP/HTTP card (RMCARD203). With the SNMP card and an IP address on the network interface, users have real-time monitoring and outlet control of the PDU. The switched outlet receptacles can be managed individually or collectively. The LCD panel provides local monitoring of the PDU and on/off control for the outlets. It can also be used to measure the electrical current (displayed in amperes) used by connected equipment. The LCD panel also shows input and output voltages, active power consumption levels (displayed in kilowatts), and hardware and firmware versions.
Designed for datacenters and other demanding electrical applications, the PDU30SWHVT19ATNET has rugged, industrial-grade metal housing, a 10-foot AC power cord, and a cord retention tray. It can be mounted horizontally and is UL and CSA certified by ETL, and Class A FCC-certified. A three-year warranty covers the PDU and connected equipment for as long as you own the product.
Power DistributionDelivers AC power to servers, equipment, and connected devices via a power distribution unit.
Outlet Switching
Output receptacles can be turned on, turned off, or recycled on demand or at programmed times to address a number of needs, including remote rebooting of locked equipment, load shedding, power sequencing, and locking out unauthorized loads.
Automatic Transfer Switch
Dual power cords (A & B) provide redundant power sources to devices with single power supplies and can be plugged into separate compatible sources to ensure continuous access. Users select the preferred source as the primary input. CyberPower Smart App Online and Sinewave series UPS are highly recommended for use as the power source.
LCD Panel
Provides real-time meter status for current (amperes), input and output voltages, power consumptions (kilowatts), and hardware/firmware versions.
Upgradeable Hardware & LCD Firmware
Are updatable to the latest versions by using the serial communication port and included cable.
Serial Communication Port & Cable
Used to update/upgrade the hardware and LCD firmware.
Environmental Sensor Option
Supports optional environment sensor (ENVIROSENSOR).
SNMP/HTTP Card
Included and installed, RMCARD203 provides outlet control, remote monitoring, reporting, and event notifications, via Email, SMS Text, or SNMP Trap. RMCARD203 firmware is upgradeable with FTP process.
Protocol Support
This Switched ATS PDU provides protocol support for PowerPanel Business Edition, HTTP, TCP/IP, UDP, DHCP, and SNMP including SNMPv3, and IPv4, IPv6, NTP, SMTP protocols.
Administrative Rights
Administrator and user rights can be established to provide IT personnel with access to the Management Console via a web browser to monitor and/or manage the PDU settings.
- 200V - 240V 30A Switched ATS PDU with 16 IEC-320 C13 outlets, 2 IEC-320 C19 & 1 NEMA L6-30R outlets and dual NEMA L6-30P 30A high-voltage input connections
- Switched Automatic Transfer Switching (ATS) PDU to provide a redundant input power option
- Digital Display (Load, Voltage, and KW) for on-site monitoring of total PDU load
- SNMP/HTTP Network Interface for real-time outlet control, monitoring and event logging of the Switched ATS PDU
Management |
|
Limited Warranty | 3 Year |
Input Voltage | 230 V AC |
Input Current | 30 A |
Input Voltage Range | 200 V AC - 240 V AC |
Output Voltage Range | 200 V AC - 240 V AC |
Additional Information |
|
Package Contents |
|
Certifications & Standards |
|
Environmentally Friendly | Yes |
Environmental Certification | RoHS |
Energy Star | No |
Product Type | PDU |
Manufacturer Part Number | PDU30SWHVT19ATNET |
Manufacturer Website Address | http://www.cyberpowersystems.com |
Manufacturer | CyberPower Systems, Inc |
Product Model | PDU30SWHVT19ATNET |
Product Name | PDU30SWHVT19ATNET Switched ATS PDU 200-240V 30A 2U 19-Outlets (2) L6-30P |
Brand Name | CyberPower |
Weight (Approximate) | 7.60 kg |
Mount Type | Rack-mountable |
Rack Height | 2U |
Cord Length | 10 ft |
Height | 3.50" (88.90 mm) |
Width | 17.05" (433.07 mm) |
Depth | 9.30" (236.22 mm) |
Plug/Connector Type | NEMA L6-30P |
Phase | Single Phase |
Receptacle Type | IEC 60320 C19 |
NEMA L6-30R | |
IEC 60320 C13 | |
PDU Type | Switched Auto Transfer Switch |
Receptacle Detail | 1 x NEMA L6-30R |
16 x IEC 60320 C13 | |
2 x IEC 60320 C19 | |
Plug/Connector Detail | 2 x NEMA L6-30P |