Schluter Systems DITRA-Heat-E Floor Heating DHEHK Cable DHEHK12038 120V 37.5 Ft² 475W

Save 27%
SchluterSKU: PL13-DHEHK12038
filler

Price:
Sale price$364.99 Regular price$499.99
 更多支付选项

Description

Schluter-DITRA-HEAT-E-HK are twisted pair heating cables designed for integration with the DITRA-HEAT uncoupling membrane in interior floor warming applications. Important tips on selecting Schluter-DITRA-HEAT heating cables: Don't buy heating cables to do the entire tiled area: it will be too much! Very important: NEVER CUT OR MODIFY the heating cable. This will change the resistance of the cable and could damage it and cause it to overheat. The cable can also be laid out in alternating intervals of three, then two spikes, in certain areas or for the entire floor. This practice may be used to increase heating capacity (e.g., on uninsulated or below-grade concrete subfloors) or to use a longer cable in a given area (e.g., when the three-spike arrangement does not meet the minimum spacing from walls, partitions, etc.). Four studs apart is not recommended as it may result in uneven temperature. Minimum distance from walls, partitions and fixed cabinets: 2" (50 mm). Minimum distance from heat sources (baseboard heaters, fireplaces, forced-air heating systems, etc.): 8" (200 mm). Minimum distance from drain and forced air ducts: 4" (100 mm). Minimum distance from centerline of toilet drains: 7" (180 mm). NEVER install heating cables under vanities with no air space underneath, bathtub platforms and freestanding bathtubs with no air space underneath, or in kitchen cabinets and islands and other fixtures, or in small storage or clothing closets where flooring may continue. Excessive heat will build up in such enclosed spaces, which could result in overheating. NEVER run the heating cable under or through a wall, partition or through a floor. NEVER install the fitting (black plastic piece to join the cold wire and the grey heating cable) in a wall, as this could cause overheating, system failure or damage. The connection must be completely recessed under the floor covering, as explained in the heating cable installation instructions. It is useful to provide a buffer zone, as it is not possible to predict exactly where the heating cable will terminate. The buffer zone is an area where heating is not essential and is not intended to receive the cables, e.g. behind a toilet or near a door opening. This area allows the excess heating cable to be concealed. The heating cables can also be laid 6" (150 mm) from the walls to create the buffer zone. The heating cable must be tested while it is still in its reel, as well as at two subsequent stages during installation, to ensure the quality of the cable and for warranty purposes. A megohmmeter is required to perform the heating cable insulation resistance test. It is strongly recommended to perform the insulation resistance test. Please consult a qualified electrician before ordering DITRA-HEAT heating cables to select the correct voltage cables for your installation.

 

  • Cables snap into the membrane; clips and fasteners are not required
  • No self-levelers required to encapsulate the cables; installation time significantly reduced
  • No return to thermostat required
  • Produces virtually zero electromagnetic fields
  • 120 V and 240 V options available in a variety of lengths
  • Provides electric floor warming for use beneath tile, stone, or other resilient floor coverings (e.g. LVT)
  • Includes : Sensor

Specifications


Shipping and delivery Information

Estimated delivery times range from same day to 2 weeks, depending on your location, the product ordered and stock availability. External factors such as courier network disruptions can also impact delivery timelines. PuriLite strives to ship your purchase in the shortest possible time using industry standard courier services.

For any questions related to shipping and delivery, please call +1-647-254-9757, email us at info@purilite.ca or chat with us by clicking on the chat icon at the bottom right of this page.

The PuriLite Peace of Mind 30-day money back guarantee

Enjoy our peace of mind 30-day money back guarantee on all products. If you are not satisfied with any of our products, your item is eligible for return within 30 days of purchase, subject to the terms & conditions below.

1. Goods must be returned in new & unused conditions with all original packaging. Do not write or put stickers on original packaging.
2. Any shipping charges incurred by Purilite to ship the product to your destination and returns from your location to our warehouse, in case of refused shipments, are non-refundable.
3. Depending on the product purchased, the client will be responsible for shipping product back to our warehouses.
4. Restocking fees map apply once inspected at our warehouse. All credits are subject to final inspection of good upon arrival at our destination.
5. Defective products are eligible for return.

If you purchased a product and did not receive the parcel, please contact us at sales@purilite.ca and we would be happy to assist you right away! PuriLite uses secure and well-established carriers (such as Canada Post, FedEx, Purolator, UPS etc.) to ensure your purchase is delivered successfully to your doorstep. All items are delivered with a tracking ID and are traceable. If your parcel was indeed not received, we will issue back a 100% refund.

Shop with confidence knowing that your purchase is protected, and your peace of mind is our commitment. Thank you for choosing PuriLite!

Payment

American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

You may also like

Recently viewed