IND-AHF-BX-UVC-R4-120V-15C Industrial UV Ceiling Mount Air Purifier
Ratings/Features
Lamp Technology: UV-C Fluorescent
Short-wave Germicidal Light
Lamp Quantity: (2) UVC Lamps
EPA Reg. No 98409-1
Dimensions: 52"-L x 12"-W x 10"-H
EPA Est. No. 98409-TX-1
Weight: -
Voltage: 120V AC
Â
Total Watts: 370W
Â
Single-lamp Watts:Â 60W
Â
Total UV Output:Â 26.6W
Â
Single-lamp UV Output:Â 13.3W
Â
Total UV Irradiance:Â 120 uW/cm2 at 3 feet
Â
Expected Lifespan: 8,000+ Hours
UV Wavelength: 254nm
Lamp Type: T8HO 2FT
Lamp Base: G13
Replacement Lamp: -
Beam Angle: 360º
Light Configuration: Flood
Â
Internal Reflector: Polished
Â
LED Indicator Lights: In Operation, Lamp Replacement (One Light per Lamp)
Â
Safety Switch: Limit Switch
Â
Blower Capacity:Â 162 cubic ft/minute
Â
Nominal Fixture Capacity:Â 121 cubic ft/minute
Â
Max Treatment Capacity:Â 7,290 cubic ft/hour
Â
Max Room Size @ 3 Air Changes/Hour:Â 2,430 cubic ft
Â
Max Room Size @ 4 Air Changes/Hour:Â 1,458 cubic ft
Â
Max Room Size @ 5 Air Changes/Hour:Â 1,822 cubic ft
Â
Max Room Size @ 6 Air Changes/Hour:Â 1,215 cubic ft
Â
Amps:Â 3.25 A @ 120 V
Â
Ambient Operating Temp Range: -
Special Orders - Requirements
Materials: 304 Stainless Steel, Aluminum
Mounting: Ceiling Mount - Drywall, Metal, or 2x4 Grid Ceiling Compatible
Air Flow Exit: Louvered Exhaust Panel
Cord: 15' 16/3 SOOW Cord w/ 120V Cord Cap
Cord Cap: 5-15 Straight, L5-15 Twist or Pigtail
***PLEASE NOTE: UV-C light can cause temporary or permanent loss of vision, and temporary acute redness or ulceration (mild to severe sunburn) to exposed skin. To prevent exposure, do not operate the device
in any application that allows UV-C light to be visible during operation. NEVER LOOK DIRECTLY AT THE BULB OR DISINFECTING TARGET ZONE. DO NOT touch bulb with bare hands. The oils in your skin will damage the lamp. Fingerprints will result in reduced performance and significantly reduce the lifespan of the lamp unless they are removed with alcohol. Please read instruction manual for UV safety requirements before operating.***
'
Product Overview
'
function MM_openBrWindow(theURL,winName,features) { //v2.0
window.open(theURL,winName,features);
}
This unit is Made In USA - Manufactured in Texas
The IND-AHF-BX-UVC-R4-120V-15C from Larson Electronics is an Industrial UV Ceiling Mount Air Purifier that actively disinfects the surrounding air in occupied areas without noise. This unit uses two T8HO UVC lamps that provide 26.6 watts of total UV output during UV treatment. Designed for installation on drywall ceilings, metal ceilings, or dropped into a 2x4 grid ceiling, the UV air purifier operates on 120 V AC and is protected by 304 stainless steel enclosure.
*Please note: This product produces UV light. Make sure to follow all safety guidelines and protocols found in the user manual. UVC light in the proper setting kills up to 99.9% of viruses, mold, spores, and bacteria. *
The IND-AHF-BX-UVC-R4-120V-15C is a powerful sanitation solution for occupied areas in buildings. Equipped with two T8HO UVC fluorescent lamps, this system offers 26.6 watts of total UV output, within the 200nm - 280nm UV-C range (254 nm peak). The lights have an expected lifespan of 8,000+ hours and emit a flood beam pattern inside the unit. The UV chamber has a polished surface to maximize light distribution during UV treatment. Constructed of 304 stainless steel, the UV lights are enclosed inside the unit preventing UV exposure in occupied areas. A limit safety switch ensures automatic disconnection of power to the system during servicing, installation or maintenance. LED indicator lights on the unit notify individuals when the system is in operation and when the lamps must be replaced (one LED indicator light per lamp).
Blower Capacity
162 cubic ft/minute
Nominal Fixture Capacity
121 cubic ft/minute
Max Treatment Capacity
7,290 cubic ft/hour
Max Room Size @ 3 Air Changes/Hour
2,430 cubic ft
Max Room Size @ 4 Air Changes/Hour
1,458 cubic ft
Max Room Size @ 5 Air Changes/Hour
1,822 cubic ft
Max Room Size @ 6 Air Changes/Hour
1,215 cubic ft
Operation: Surrounding "dirty" air is drawn into the UV purifier via washable electrostatic filters. The "dirty" air passes through the UV sanitation chamber where it is treated with UVC light using the two T8 fluorescent lamps. The disinfection process kills up to 99.9% of viruses, bacteria, mold, spores and other harmful microbes. Clean sanitized air exits the chamber through a louvered exhaust panel and is released back into the environment. This low-maintenance air disinfection process is continuous and quiet.
Click Photos to Enlarge
5-15 Straight Blade Plug
15 Amp / 125V Rated
L5-15 Twist Lock Plug
15 Amp / 125V Rated
Flying Leads / Pigtail Wires
Wiring/Plug: This unit is equipped with 15 feet of 16/3 chemical and abrasion resistant SOOW cord that is fitted with an industrial grade cord cap for easy connection to common wall outlets. Plug options include standard 5-15 15 amp straight blade plug for 110V wall outlets with ground or NEMA L5-15 15 amp twist lock plug for 125V twist lock outlets. Alternatively, we can provide flying leads with no plug for hard wire applications or for operators who prefer to wire in user provided cord caps. Please choose pigtail option below for flying leads with no plug.
Mounting: The IND-AHF-BX-UVC-R4-120V-15C is designed to be ceiling mounted. It can be mounted directly to drywall ceilings, mounted to metal ceilings via thru holes in the mounting bracket, or dropped into a 2x4 grid ceiling. If it is installed in a grid ceiling, the purifier will sit below the grid. Therefore, the 2x4 ceiling tile needs to be installed above the purifer so that there isn't a hole in the ceiling.
Note on Environment: Sunlight and visible light fixtures do not impact the effectiveness of the disinfecting on this UVC sanitation product. Metal halide, high pressure sodium, fluorescent, and LED light fixtures can be left on. The UV radiation emitted from this product is not disrupted by any type of lighting in the environment. Put simply, NO it DOES NOT need to be dark in the area you plan to disinfect. The UV radiation is harmful to the eyes and skin, and that is why you should not be in the area while it is in operation. Please see user manual for additional safety information.
Applications: Air sanitation, occupied areas, food processing, pharmaceutical, schools, labs, warehouses, buildings, industrial, manufacturing, office, air disinfection, UV treatment, and many more.
Larson Electronics is a manufacturer and as such can build stationary and portable transformer systems to your specifications. Although we carry several models of power distribution transformer systems, we can deliver custom ordered units almost as quickly as our prebuilt units. If this model does not meet your needs, please contact us at 1-800-369-6671 or to discuss your specific requirements.
Shipping and delivery Information
Estimated delivery times range from 1 to 3 weeks, depending on your location, the product ordered and stock availability. External factors such as courier network disruptions can also impact delivery timelines. PuriLite strives to ship your purchase in the shortest possible time using industry standard courier services.
For any questions related to shipping and delivery, please call +1-647-254-9757, email us at info@purilite.ca or chat with us by clicking on the chat icon at the bottom right of this page.
Payment
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Refund Policy
Return & Refund Policy
For All non-Larson Products If you are not satisfied with a product, contact us by emailing or call 1-844-787-LITE within 30 days of receipt. A refund may be arranged excluding freight charges upon inspection. Returned merchandise must be shipped in original packaging, freight prepaid, unused, and in resalable condition, and are subject to 25% restocking fee. PuriLite inspects all returns and reserves the right to refuse credits on damaged, used or non-resalable items. Your only obligation is the freight charge and restocking fee, provided your return is complete with original packaging, all documentation, warranty cards, cables etc. PuriLite reserves the right to authorize product returns after 30 days have passed from the order date. If the product is accepted after this period, it is subject to a 25% restocking fee and credit will be issued toward future purchases only.
Shipping and handling charges are non-refundable for all returns. The customer may also be responsible for return shipping charges, insurance and shipment tracking for returned merchandise.
Once you place an order, the following products are non-returnable: custom-cut, customer built or special order items (such as matting, slings, cranes, prefab offices, buildings, mezzanines, assembled lockers and regularly stocked items such as generators, pressure washers, water and trash pumps, snow throwers, radio headsets, striping paint, line stripers, floor care machines, vacuums, custom fabric chairs, forklifts) your order is considered non-cancellable and any custom-cut, customer built or special order items purchased by you are also non-returnable. Consumable style bulbs or lamps are not returnable. There are no returns on any medical and/or sanitizing products for obvious safety reasons. This includes PPE (including masks), tests, thermometers, sprayers and UVC lighting of any kind (portable and surface).
Leased and hazardous items are also non-returnable. Contact customer service for a complete list of applicable products.
Larson product return policy Every order is tested prior to shipping. The product is tested before it is put into the shipping box, crate, pallet, etc. Larson take pictures and videos of every product for every order being shipped, and store these pictures and videos with the order number in our system. Because of the complexity of some of our products, we have a very limited return policy.
For safety reasons, we do not accept returns on any hazardous location, explosion proof or intrinsically safe products. Once these products leave the factory, we cannot be sure what happens to them. We must re-build and re-certify the units to specification to ensure that the next customer receives an item that is safe to use. This is cost prohibitive. For that reason, we do not accept returns on classified products. We do not accept returns on transformers, phase converters, or frequency converters. In order to install one of the aforementioned products, typically customers will modify the product (i.e. penetrate the housing to make connections, punch out knockouts, remove or damage tinning on lead wires during installation). Because we video test every unit before it ships to ensure the unit operates as described, we know when they leave here the units are operationally functional and meet the output voltage when supplied with the input voltage per the product specification. To be clear, we do not accept returns on these items under any circumstances for these reasons.
Products that are not addressed in the above two conditions must be returned in new, unused condition.
Below are some additional considerations:
Electrical/electronic parts are easily damaged by improper installation or testing. Because electronics are very sensitive to voltage overloads, it does not take much of a voltage spike to ruin a component. Because of this risk, all electrical products returned will undergo electrical testing and assessed a testing fee. This fee will be subtracted from the final return value.
Consumable style bulbs or lamps are not returnable.
Products that contain emergency backup components are subject to very narrow warranty terms and do not qualify for return. For customer convenience, we engage the battery pack prior to shipping all emergency backup products. Many times, particularly with hazardous location rated products, the battery packs are difficult to access and the customer generally plans to install the units shortly after receipt of the shipment. Battery backup components using older technologies (Nicad, NIMH, SLA, etc) will fail quickly if they do not maintain valid grid tie support. In other words, the batteries must receive a consistent maintained charge to perpetuate long lifespans. Battery backup products that are shelved (not installed) for periods greater than 3 weeks will likely fail and need replacement sooner. This replacement will not be covered under warranty. This can also occur is the units are installed but the grid tie option is not connected correctly. Customers can specify that they do not want the battery pack to be engaged at the time of ordering if they plan to shelve the units for long periods of time prior to installation.
There are many products on the site and not all pictures depict the exact configuration of each product. Many products are custom built and/or built on demand. In some cases, products are designed and not sold immediately and rendering may be used. In all cases, the end product is built to the specification listed and the pictures shown may be close approximations. Pictures are more likely to be close approximations with more complex products, including transformers, power distribution systems, control systems, light tower systems and other highly customizable products. In no way does the approximation validate a potential return. We always build to the specification. If customers have questions, they should ask prior to purchase to clarify.
There are no returns on any medical and/or sanitizing products for obvious safety reasons. This includes PPE (including masks), tests, thermometers, sprayers and UVC lighting of any kind (portable and surface)
Many international orders, specialty orders and other complex build orders require prepayment in advance. This prepayment represents a commitment to the order. Cancelling the order will result in a deduction from the original amount paid if any refund is available, since an investment of time and money is typically required to acquire materials and prepare the order. While not all orders in this category require prepayment, cancellation fees may apply to other build orders as well. The percentage of the deduction is at Larson’s discretion but usually ranges from 30 to 50%.
How to Return For all returns, you can email us at sales@purilite.ca. You will need the invoice number in the subject line of the email. You can use one of your preferred carriers. Please note that for freight collect shipments, you are responsible for order tracking once the freight is loaded onto the truck. In addition, PuriLite Industrial cannot assist you with filing damage claims with your carrier.
All returns must be authorized by PuriLite. A Return Authorization Number must be obtained from PuriLite Customer Service Department, and the client must provide the Invoice number at the time of the request. The following conditions must be met. Failure to do so could result in refusal of a shipment by us.
At the time of the return, goods must be a stock item with PuriLite and the returned quantity must correspond to the quantity of the original packaging
Approval and shipping destination must be obtained from PuriLite before returning goods;
Goods must be returned to the appropriate location within 10 working days after receiving the return authorization number;
The return authorization number and invoice number must be identified on the return address label;
Goods must be in their original packaging, arrive undamaged and in resalable form
All returns are to be sent prepaid;
Specially ordered goods are non returnable – these products are identified with a part number beginning with a // on quotes and invoices.
Goods damaged in transit must be signed as damaged by the receiver and carrier at the time of receipt of goods in order to request credit from PuriLite.
PuriLite reserves the right to deny any Returns or Claims if the above conditions are not met.
Orders for products affected by x-factor events such as viral outbreaks and other extreme circumstances CANNOT be returned once shipped and billed.