40W Industrial UVC Corner Mount Fluorescent Fixture - (1) 4' UV Lamp - Shatter Proof Bulbs - Surface Mount - Ideal for Elevator Use

LARSON ELECTRONICSSKU: PL3-IND-EV-SS-48-1L-UVC-V1-MS
filler

Price:
Sale price$2,186.00

Description

Specifications / Additional Information
This unit is Made In USA - Manufactured in Texas
IND-EV-SS-48-1L-UVC-V1-MS Corner Mount Elevator UVC Fixture Ratings/Approvals
Listing: - (1) 4' UV Fluorescent Lamp
Lamp Technology: UV Fluorescent Germicide Applications
Dimensions: 48.75" x 8.875" Ideal for Elevator Cars
Weight: - EPA Reg. No 98409-1
Voltage: 120-277V AC EPA Est. No. 98409-TX-1
Frequency: 50/60 Hz  
Total Watts: 40W  
Single-lamp Watts: 40W  
Total UV Output (Watts): 11.78W  
Single-lamp UV Output (Watts): 11.78W  
Total Radiant Intensity: 117 uW/cm2  
Single-lamp Irradiance: 145 uW/cm2  
Lamp Life: 8,000 Hours  
UV Band: UVC 254nm (200nm - 280nm)  
Peak Wavelength: 280nm  
Lamp Type: UV T8 Fluorescent  
Lamp Base: G13 (Medium Bi-Pin Fluorescent)  
Replacement Lamp: -  
Beam Angle: -  
Lighting Configuration: Flood Pattern  
Ballast Quantity: 1
Ballast Voltage: 120-277V AC, 50/60 Hz
Sensor Type: Integrated Microwave Motion Sensor
Sensor Coverage Area: 12' x 12'
Amps: 0.6 A @ 120 V, 0.3 A @ 240 V, 0.26 A @ 277 V  
Operating Temp Range: -30°C to 85°C  
Housing Material: 304 Stainless Steel  
Hardware/Hub Material: Zinc Coated Hub Special Orders - Requirements
Lens Material: N/A
Lamp Coating: Shatter Resistant PEF Coating
Mounting: (2) 45° Rear Mounted L-Brackets
Hub Quantity: 2
Wiring Hub Size: 1/2" or 3/4" Threaded
***PLEASE NOTE: UV-C light can cause temporary or permanent loss of vision, and temporary acute redness or ulceration (mild to severe sunburn) to exposed skin. To prevent exposure, do not operate the device in any application that allows UV-C light to be visible during operation. NEVER LOOK DIRECTLY AT THE BULB OR DISINFECTING TARGET ZONE. DO NOT touch bulb with bare hands. The oils in your skin will damage the lamp. Fingerprints will result in reduced performance and significantly reduce the lifespan of the lamp unless they are removed with alcohol. Please read instruction manual for UV safety requirements before operating.***
' Product Overview '
This unit is Made In USA - Manufactured in Texas The Larson Electronics IND-EV-SS-48-1L-UVC-V1-MS Corner Mount UV Fluorescent Fixture provides UVC illumination at a 45° angle to the ground which is ideal for use in elevators. This 40-watt unit features one, 4-foot UV fluorescent lamp with shatterproof coating, housed in a 304 stainless steel housing. The luminary caters to corner surface mounting, operates on 120-277V AC, 50/60 Hz, and is equipped with a motion sensor and automatic timer. For best results, combine 2-3 of these fixtures inside each elevator car. *Please note: This product produces UV light. Make sure to follow all safety guidelines and protocols found in the user manual. UVC light in the proper setting kills up to 99.9% of viruses, mold, spores and bacteria. * The IND-EV-SS-48-1L-UVC-V1-MS is a fluorescent-based UV lighting system for elevators requiring effective sanitation or disinfection. Consisting of one, 4-foot fluorescent UV lamp, the 40-watt unit offers 254nm UVC output with a wavelength range of 200nm to 280nm. Radiant intensity is 117 uW/cm2 per lamp and total UV output is 11.78 watts. This UV fixture operates on 120-277V AC, 50/60 Hz (ballast voltage) and features a G13 medium bi-pin cap base. The UV lamps contain an 8,000-hour useful lifespan. The UV light's housing is constructed of 304 stainless steel, with zinc-coated hubs. A durable PEF coating makes the lamp shatter resistant and provides protection from impacts. Should the bulb break during an emergency, the internal contents and glass will remain trapped inside the unit. This coating adds an extra layer of safety for elevator passengers and maintenance crews. UV radiation from the unit can damage the skin and eyes without proper protection. Operators should avoid exposure to the eyes and skin when the unit is unshielded (for use in enclosed environments only). In the event of lamp breakage, it is recommended to ventilate the room for 30 minutes and clean the area with gloves (not a vacuum cleaner). Contents should be stored in a sealed plastic bag and brought to a waste/recycling facility. Motion Sensor: The IND-EV-SS-48-1L-UVC-V1-MS is equipped with a microwave motion sensor for an additional layer of safety while the unit is in use. Due to the potential harm UVC light can cause to a person's skin and vision, it is unsafe to be near the light while it is powered on. To avoid accidental exposure to the UV light produced by this elevator light, it is equipped with a 360° motion sensor. When the motion sensor detects movement inside the elevator car, it will power off the light. When no motion has been detected for at least 5 minutes, the unit will power back on. This component is capable of sensing through thin materials (it does not need direct line of sight) and effectively covers 12' x 12' areas. Timer: The IND-EV-SS-48-1L-UVC-V1-MS features a digital timer that shuts the unit off after five minutes of runtime. This saves energy by preventing the fixture from running continuously after disinfection has taken place. Mounting/Wiring: The IND-EV-SS-48-1L-UVC-V1-MS features a corner surface mounting system that allows the beam to project at a 45° towards the ground. Operators may use two L-bracket mounting brackets (located on the rear of the fixture) for secure installations. The brackets both have a 45° bend that allows the fixture to be angled downwards during installation. Combine 2-3 of these fixtures in each elevator car for best results. Power connections to the UV unit can be completed via two accessible, threaded wiring hubs (1/2" or 3/4"). Note on Environment: Sunlight and visible light fixtures do not impact the effectiveness of the disinfecting on this UVC sanitation product. Metal halide, high pressure sodium, fluorescent, and LED light fixtures can be left on. The UV radiation emitted from this product is not disrupted by any type of lighting in the environment. Put simply, NO it DOES NOT need to be dark in the area you plan to disinfect. The UV radiation is harmful to the eyes and skin, and that is why you should not be in the area while it is in operation. Please see user manual for additional safety information. Applications: Elevator car disinfection.

Shipping and delivery Information

The PuriLite Peace of Mind 30-day money back guarantee

Payment

American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

You may also like

Recently viewed