Hazardous Location Solar System - C1D2 - (2) 150W EXP Solar Panels (2) 100aH SLA Batteries - PLC

LARSON ELECTRONICSSKU: PL3-HAL-SPK-2X150PNL-SCS-2X100AH-24-PLC
filler

Price:
Sale price$17,234.00

Description

Specifications / Additional Information
HAL-SPK-2X150PNL-SCS-2X100AH-24-PLC 150W Explosion Proof Solar Panel System Ratings/Approvals
Solar Panel Specs Class I, Division 2
Solar Panel Qty: (2) Low Voltage Protection
Solar Cells: Crystalline 6" Silicon (156 x 156mm) NEMA 3R
Panel Dimensions: 59.4" x 26.5" x 2" Included Program Logic Controller (PLC)
Cells Orientation: 36 Cells (2) 150W C1D2 Solar Panels
Voltage: 12V(Nominal)
Maximum System Voltage: 1000V
Total Watts: 300W
Current: 8.3A
Module Efficiency: 14.6%
Tolerance: +10%/-5%
Limiting Reverse Current: 8.5A
Temperature Coefficient of Isc: 0.105%/°C
Temperature Coefficient of Voc: -0.360%/°C
Temperature Coefficient of Pmax: -0.45%/°C
Maximum Fuse Rating: 20A
Materials: Silver Anodized Aluminum (Frame), Polyester (Back), EVA (Encapsulant)
Cover: High Transmission 1/8" Glass
Hubs: (4) Terminal Screw Connection Blocks
Mounting: NA - Customer Provided
Color: White
 
Battery Bank Specs
Dimensions: 40.125"H x 25.25"W x 17.125"D
Battery Type: SLA
Total Capacity: 200aH
Total Usable: 100aH
Materials: Aluminum, Stainless Steel
Hub Qty: (6)
Hub Size: (6) 3/4" NPT
Hub Location: (6) 3/4" NPT @ Bottom of Enclosure
 
MPPT Charge Controller Specs
Voltage: 12V, 24V or 48V DC
Maximum Battery Current: 60A
Nominal Maximum Operating Power: 800W @ 12V, 1600W @ 24V, 3200W @ 48V
Peak Efficiency: 99%
Maximum PV Open Circuit Voltage: 150V DC
Battery Operating Voltage Range: 8-72V DC
Maximum Self-consumption: 2.7W
Transient Surge Protection: 4500W/Port
Charging Algorithm: 4-stage
Charging Stages: Bulk, Absorption, Float, Equalize
Ambient Operating Temp: –40°C to +45°C
Protection: Overload, Short Circuit, High Voltage, High Temperature, Lightning/Transient Surges, Reverse Current @ Night, Remote Battery Sensor (RTS)
Communication Ports: MeterBus, RS-232, EIA-485, Ethernet, EMC-1
 
' Product Overview '
The HAL-SPK-2X150PNL-SCS-2X100AH-24-PLC Hazardous Location Solar System from Larson Electronics is designed for sustainable energy applications in Class I, Division 2 hazardous locations. The 12V DC system features 300W solar panels, SLA batteries @ 200aH capacity, MPPT controller, programmable logic controller and low voltage protection device. A NEMA 3R heavy-duty enclosure protects the system`s components from outdoor elements. The HAL-SPK-2X150PNL-SCS-2X100AH-24-PLC is a powerful solar-powered system for Class I, Division 2 rated hazardous locations. This 12V system includes two 150-watt solar panels, two 100aH SLA batteries, programmable logic controller, low voltage protection device and a 60-amp MPPT charge controller. The solar panels require customer-provided mounting for secure installation at the site. Solar Panels: The two, 150-watt solar panels operate on 12V (nominal) with a module efficiency rate of 14.6 percent. At maximum power, the units offer 18.1V and a current of 8.3A. Featuring a Class C application class, the modules come with a 20A maximum fuse rating. The lightweight units weigh 26.5 lbs and measure 59.4" x 26.5" x 2". IEC and UL certified, the solar panels are designed to withstand rugged, outdoor environments. The frame is constructed of silver anodized aluminum, while the back cover is made out of white polyester for insulation. For extra protection, the front cover is constructed of high transmission glass (1/8" thick). The hazardous location solar panel comes with a sturdy J-type junction box with accessible terminals for connections to other components of the solar-powered system. A total of four terminal screw connection blocks is available, capable of accepting 8-14 AWG wires. Battery Bank/Charge Controller: This system is equipped with two, 100aH SLA batteries at 200aH capacity and 100aH usable. Inside the enclosure, operators are provided access to an MPPT charge controller. Capable of operating at 99% peak efficiency, this component features a maximum battery current of 60 amps. The 4-stage charge controller can handle bulk, absorption, float and equalize charging stages. Protective features include the following: Overload, Short Circuit, High Voltage, High Temperature, Lightning/Transient Surges, Reverse Current @ Night. The controller is supported by an included remote battery sensor. For connections to the controller, the following communication ports are available: MeterBus, RS-232, EIA-485, Ethernet, EMC-1. The batteries, MPPT charge controller and low voltage protection device are housed inside a Class I, Division 2 enclosure. The NEMA 3R enclosure is constructed of aluminum and stainless steel. A total of six, 3/4" NPT hubs can be found at the bottom of the unit during installation. Applications: Hazardous locations, chemical processing plants, refineries, oil and gas, solar-powered systems, remote locations, alternative energy, sustainable energy systems, solar lighting, portable power, battery-powered systems, rechargeable lighting and more.  

Shipping and delivery Information

The PuriLite Peace of Mind 30-day money back guarantee

Payment

American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.