Larson PCO Hydroxyl Generator - (4) 55W UVC Lamps, 500 CFM Fan - MERV 13 Air Filter - Inlet/ GFCI Outlet - DT

Larson ElectronicsSKU: PL3-IND-HG-HC2-UVC-4L-R2
filler

Precio:
Precio de venta$18,578.00

Descripción

This unit is Made In USA - Manufactured in Texas
The Larson Electronics IND-HG-HC2-UVC-4L-R2 PCO Hydroxyl Generator provides no-contact, no-ozone air sanitation inside buildings and 1,500+ square feet spaces. This no corona generator features four 55-watt UVC germicidal lamps with a titanium dioxide coated stainless steel mesh (protected by a 304 stainless steel lamp shield), MERV 13 air filter, 500 CFM nickel chrome plated fan and digital timer. All system components are secured inside a portable, wheeled case with two padlockable hasps for security and a retractable, soft-grip handle. Available connections include one 5-15 inlet and one 5-15R GFCI outlet for feed-thru operation.
*Please note: This product produces UV light. Make sure to follow all safety guidelines and protocols found in the user manual.
*
The IND-HG-HC2-UVC-4L-R2 is a powerful air purifying solution for occupied areas and industrial facilities. This no ozone generator has four, twin tube T16 bulbs that offer 253.7 nm UVC output. Compatible with 120V AC, the UV lamps contain a 16,000-hour useful lifespan and features a titanium dioxide (TiO2) coated stainless steel mesh at the top and bottom. This component serves as a catalyst, which reacts to the UV lights during use. The reaction generates hydroxyl molecules that are capable of sanitizing bacteria, viruses, mold, odors, volatile organic compounds (VOCs) and contaminants. A 304 stainless steel lamp shield prevents stray light from exiting the unit.
Suitable for 1,500+ square feet spaces, the no ozone generator is equipped with a 500 CFM fan to promote air flow in the surrounding area. This component has a nickel chrome plating for long-term durability and corrosion resistance. An 18" x 18" x 2" MERV 13 air filter offers additional protection and filtering against bacteria, pollen, smoke, dust and more. The air filter features tie-down straps that cater to quick filter changes in the field without tools. Operators may access a digital timer for setting timed usage (the unit automatically turns off after a set duration). A 3-position switch enables the selection of the following operating modes: on with timer, on continuous (no timer) and off.
Hydroxyl is considered to be more effective and less harmful than ozone for humans. By comparison, ozone is mostly found in the stratosphere approximately 8 miles from the surface. Very little amounts of ozone exist on the ground because such elements are very harmful to humans. Hydroxyl can be found on the surface and does not impose the same hazards and dangers associated with ozone. Such compounds exist naturally in the atmosphere and help get rid of pollutants in the environment. Hydroxyl is more reactive than ozone and is capable of disinfecting a wider range of VOCs, germs and odors. This form of sanitation is also recommended for use with sensitive materials, as well as in occupied areas. Suitable for cleaning the ducts, AC coils, HVAC systems and surrounding air, there is no downtime associated with using hydroxyl generators (the area does not need to be aired out or vented for hours after treatment). Sanitizing with hydroxyl generators is most effective when there is high volume of air flow, the environment is humid or filled with moisture and a filter is present to remove or trap oxidized elements.
Hydroxyl Accelerator:
This unit can be supplemented with our hydroxyl accelerator to boost effectiveness and sanitation. The optional component generates cold mist vapor near the intake vent of the air purifier, which raises the humidity level inside the system as surrounding air is drawn into the unit. Increased humidity levels enhance the purifier by streamlining the hydroxyl formation process (moisture generated by the accelerator is broken down into hydroxyl radicals). Distilled or purified water is recommended in order to preserve the lifespan of the accelerator.
UV radiation from the unit can damage the skin and eyes without proper protection. Operators should avoid exposure to the eyes and skin when the unit is unshielded. In the event of lamp breakage, it is recommended to ventilate the room for 30 minutes and clean the area with gloves (not a vacuum cleaner). Contents should be stored in a sealed plastic bag and brought to a waste/recycling facility.
Inlet/Outlet:
A 15-amp 5-15 inlet is available for 120V connection with standard extension cords. This unit caters to feed-thru operation via one 15-amp 5-15R GFCI outlet. Operators can run up to two units or two other equipment. The maximum load for the entire system cannot exceed 15 amps or the amp rating of the used extension cords. Switching this air purifier off does not cut power to the output receptacle or to any connected equipment.
Portable Case:
The IND-HG-HC2-UVC-4L-R2 is mobile via a portable case with two wheels. Constructed of HPX resin, the heavy-duty case has an O-ring seal. Retractable, soft-grip and side-located handles make transportation easier over surfaces. Two padlockable hasps are available for security.
Note on Environment:
Sunlight and visible light fixtures do not impact the effectiveness of the disinfecting on this UVC sanitation product. Metal halide, high pressure sodium, fluorescent, and LED light fixtures can be left on. The UV radiation emitted from this product is not disrupted by any type of lighting in the environment. Put simply, NO it DOES NOT need to be dark in the area you plan to disinfect. The UV radiation is harmful to the eyes and skin, and that is why you should not be in the area while it is in operation. Please see user manual for additional safety information.
Applications:
Germicidal, emergency services, vehicles, occupied areas, buildings, industrial sites, commercial locations, offices, malls, schools, disinfection, food processing, air disinfection, pharmaceuticals, biotechnology and more.
Contact info@purilite.ca for more information about our custom options tailored to meet your specific industry needs.

Specifications
Listing: -
Lamp Technology: UV Fluorescent
Lamp Qty: (4)
Unit Dimensions: 31.3" x 20.4" x 12.2"
Weight: -
Voltage: 120V AC
Total Watts: -
Single-lamp Watts: 55W
Total UV Output (Watts): -
Total Radiant Intensity: -
Luminous Efficacy: -
UV Lamp Life: 16,000 Hours
UV Band: UVC 253.7nm (200nm - 280nm)
Color Temperature: -
Color Rendering Index: -
Lamp Type: Twin Tube T16
Lamp Base: 4-pin on a Single End 2G11
Replacement Lamp: -
Beam Angle: -
Lighting Configuration: Flood Pattern
Light Mesh Type: Titanium Dioxide (TiO2) Coated Stainless Steel - Top and Bottom
Generated Sanitizing Compound: Hydroxyl
Lamp Shield: Included
Power Efficiency: -
Power Factor: -
CFM (Fan): 500 CFM
Recommended Room Size: 1,500+ square feet
Air Filter Type: 18" x 18" x 2" MERV 13 w/ Tie-down Straps
Digital Timer: Included
Switch Type: 3-position
Operating Modes: On w/ Timer, On Continuous (No Timer) and Off
Amps: -

Operating Temp Range: -
Materials: 304 Stainless Steel (Lamp Shield), HPX Resin (Case)
Fan Finish: Nickel Chrome Plating
Mounting: Portable Wheeled Case - (2) Wheels; Retractable and Side-located Handles
Security: (2) Padlockable Hasps
Inlet: 15A 5-15 Inlet [125V]
Outlet: 15A 5-15R GFCI
Maximum Feed Thru Connections: Up to (2) Units - Max Load Cannot Exceed 15A or Amp Rating of Extension Cords