Explosion Proof Carbon Dioxide Sensor - 0-2000 ppm - 0-50% Max Range - Analog

LARSON ELECTRONICSSKU: PL3-EXP-SNR-TG-EC-ITS-ALG-CD2000
filler

Precio:
Precio de venta$8,506.00

Descripción

Specifications / Additional Information
EXP-SNR-TG-EC-ITS-ALG-CD2000 Carbon Dioxide Gas Sensor Features/Ratings
Listing: NRTL Listed for United States and Canada Class I, Divisions 1 & 2, Groups B, C, D
Dimensions: 7.12" x 5.43" x 5.11" CO2 Sensor
Weight: 4 lb LCD Graphic Display
Gas Type: Carbon Dioxide (CO2) Non-Intrusive Magnetic Operation
Transmitter Type: Electrochemical Without Arms Internal Data Logger
Voltage: 12V DC to 30V DC  
Amps: 250mA @ 24V DC Maximum, 3-wire Mode  
Sensor Holder: Integral Holder  
Output: Analog  
PPM Detection Range: 0-2000 ppm  
Sensor Sensitivity: 120 Lm/W  
Response Time: T90 < 30 Seconds  
Accuracy/Repeatability: ±2%LEL (0.1%VOL) Methane  
Zero/Span Drift: ±1%LEL (0.05%VOL) Methane, per month  
AO Range: 4mA is 0%LEL, 20mA is 100%LEL (Programmable Down to 50%LEL)  
Alarm Relays: (3) SPST  
Contact Rating: 5A @ 250V AC, Resistive Load  
Relay Coils: Normally Energized or De-energized, Programmable  
Controls: Non-intrusive (4 Magnetic Switches on Front of Transmitter)  
Serial Interface: HART 1200 Baud Modem Interface, Registered DDL File or Modbus 1200-600,14.4k,28.8k, RS232/RS485 or ASCII Text Output for Printing Data Log  
Max Range: 0-50%  
Output Range: Scalable 4-20 mA Special Orders - Requirements
Operational Temp Range: >-25º to +55ºC
Operational RH Range: 0-95% Non-condensing Toll Free: 1-800-369-6671
Housing: Cast Aluminum
Mounting: Surface (2) 5/16"-D Openings
Hub Size: 3/4" NPT Threaded
' Product Overview '
The EXP-SNR-TG-EC-ITS-ALG-CD2000 Carbon Dioxide Gas Sensor, is a Class I Division 1 explosion proof toxic gas transmitter fitted with a sensor, that offers users a unique sensor response testing system, reliable in hazardous locations. This testing system verifies response checks with real gas sample generated on demand, and features an easy to see LCD graphics display, internal data logger, alarms and may additional features that simplify installation, operation and maintenance. This explosion proof gas sensor is Class I, Divisions 1 & 2 certified and is fitted with a carbon dioxide sensor that detects 0-2000 ppm. The EXP-SNR-TG-EC-ITS-ALG-CD2000 is built with cast aluminum housing, ideal for detecting gas leaks and other emissions and as a control system for oil rigs, manufacturing processes and other hazardous locations where explosive gases are present. The EXP-SNR-TG-EC-ITS-ALG-CD2000 toxic gas sensor that is configured to detect carbon dioxide vapors within a 0-2000ppm (parts per million) concentration, and includes an electrochemical transmitter, an integral sensor holder and non-digital output. An LCD graphics display shows gas concentrations in large, easy to read numbers and also provides operators with alarm indication and menus to set up operating parameters. A backlight is available for use when 3-wire mode is used. This sensor also includes an internal data logger which stores measured gas values at intervals chosen by the user, which can be pulled up on the LCD screen at any point, or downloaded using an interface. This carbon dioxide sensor has non-intrusive operation, allowing operators to calibrate, view data, set up alarms and complete other tasks with a magnetic tool, eliminating the need to open the sensor's enclosure. All program settings are password protected. Also included with this sensor is a scalable 4-20 mA programmable output range, three internal alarm relays transmitter, and analog output set to user defined values for loop testing without needing to apply gas to the sensor. Designed to operate on 12V DC to 30V DC, the unit contains three SPST alarm relays. The contacts are rated at 5A @ 250V AC, resistive load. During use, the sensor can detect hazardous gas with ±2%LEL (0.1%VOL) accuracy/repeatability. Zero/span drift is ±1%LEL (0.05%VOL). This device features a HART® 1200 baud modem interface, registered DDL file or Modbus ® 1200-600,14.4k,28.8k, RS232/RS485 or ASCII text output (for printing data log) serial interface. The EXP-SNR-TG-EC-ITS-ALG-CD2000 is fitted with a carbon dioxide gas sensor, which plugs directly to the transmitter. This gas sensor is used to detect a wide variety of carbon dioxide gases, which can be calibrated by the user based on application. This gas detector contains a sensor, amplifier and memory module in one unit, allowing it to be calibrated independently and plugged into any detector for immediate use with no adjustments needed. Hubs: This explosion proof sensor contains a 3/4" NPT threaded opening at the bottom of the unit. Mounting: The EXP-SNR-TG-EC-ITS-ALG-CD2000 can be secured on surfaces via two 5/16" mounting holes.

Shipping and delivery Information

The PuriLite Peace of Mind 30-day money back guarantee

Payment

American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Su información de pago se procesa de forma segura. No almacenamos los detalles de la tarjeta de crédito ni tenemos acceso a la información de su tarjeta de crédito.

You may also like

Recently viewed