Hazardous Area Emergency LED Light -Class 1 Div 2 Groups A, B, C, D & Class 2 Div 2 F,G - 4' 4 lamp

LARSON ELECTRONICSSKU: PL3-HALS-EMG-48-4L-LED
filler

Precio:
Precio de venta$3,996.00

Descripción

Specifications / Additional Information
HALS-EMG-48-4L-LED Hazardous Area Ratings/Approvals
NRTL Listed for United States & Canada Class 1 Division 2, Groups A, B, C, D
Dimensions: W-15" L-49 3/4 " H-6 1/8 " Class 2 Division 2, Groups F,G
Weight: 33 lbs. NRTL Certified to UL 595 Outdoor Marine Type (Saltwater)
Total Watts: 112 watts (28 Watts per Lamp) NRTL Certified to UL 1598A Marine Type
Voltage: Universal 120/277VAC 50/60Hz California Title 24 Compliant
Total Lumens: 14,000 (3,500 per Lamp)
Lamp Life Expectancy: 50,000 Hours
Luminous Efficacy: 125 Lumens per Watt
Operating Temp Range: T4A Rated -30 C to 85 C
Beam Angle: N/A Toll Free: 1-800-369-6671
Color Temp: 5300K Intl: 1-214-616-6180
Mounting: Bracket Standard - Pendant/Cable Mount Optional Fax: 1-903-498-3364
Wiring Hub: 1/2 inch threaded
' Product Overview '
Made in the USA The Larson Electronics HALS-EMG-48-4L-LED Hazardous Area Fluorescent Light Fixture is rated Class 1 Division 2 Groups A, B, C and D, NRTL Certified to UL 1598A listed, has a T4A temperature rating and ideal for open air hazardous locations where flammable chemical/petrochemical vapors may be occasionally encountered. ***PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO THIS HAZARDOUS LOCATION LIGHT FIXTURE*** The HALS-EMG-48-4L-LED light fixture is a 4 foot long, 4 lamp, Class 1 Division 2 Groups A, B, C and D hazardous area fluorescent light and a good choice for use in hazardous areas requiring maximum illumination. This fixture is T4A temperature rated, comes standard with four 28 watt LED bulbs. The lamps are protected by an aluminum framed hinged glass door secured with four turn latches and the fixture is constructed of copper free aluminum alloy. The lamp reflector is corrosion resistant heavy gauge aluminum and coated with a high gloss reflective finish. This fixture is multi-voltage capable and is NRTL Certified to U.L. 595 and UL 1598A Marine Type approved for use marine environments. The HALS-EMG-48-4L-LED provides operators in hazardous locations with a powerful, reliable and affordable lighting solution for open areas where flammable chemicals and vapors may occasionally be present. This emergency backup only fluorescent light works, mounts and is wired like our HALS-48-4L-LED hazardous area LED light fixtures. The main difference is that we add a battery backup unit that adds emergency light functionality to the fixture. With an integrated emergency ballast, this explosion proof LED light will continue to operate one LED lamp for 90 minutes at 3,500 lumens after the main electrical power to the light is severed. Once standard electrical power is restored, the emergency battery pack will be recharged. The solid state design of the included LED lamps give this fixture superior resistance to damage from vibrations and extremes in temperature as well as a lamp service life over twice that of standard T5-bulbs. The 28 watt LED lamps produce more illumination than standard T5 bulbs, but draw only 1/3rd of the current. The current generation of Larson Electronics LED T-series style bulbs produce 15% more light than our HALS-48-4L-LED fixture outfitted with two T5 bulbs. This fixture is multi-voltage capable (not multi-tap) and works on the following voltages: 120 Volt 60 HZ, 220 Volt 50 HZ, 240 Volt 60 HZ, 277 Volts 60 HZ. We also make a 12-24V DC version for low voltage applications (-LV suffix). Standard Surface Mount Brackets: Each surface mounting bracket is attached on each end of the light and allows the operator to adjust the angle of the entire fixture. Pendant and cable mounting options are also available for operators who wish to mount these fixtures away from the ceiling surface. Each is illustrated above beginning left to right; Cable, Adjustable Surface Mount and Pendant. Suggested Applications: Aircraft maintenance, Oil drilling rigs, Refineries, Solvent and cleaning areas, Chemical manufacturing, Waste treatment plants, Gas processing plants.
Made in USA Quality
1. Each unit dialectically tested. 2. Fixture arrives assembled and lamped to reduce installation time and cost. Adjustable mounting brackets enable the operator to choose any mounting angle for the fixture, where other models may only offer one or three choices. 3. Fixture constructed of extruded corrosion resistant copper free aluminum alloy. 4. Relamping done via 4 turn latches, which enable the operator to unlatch the hinged door and access the lamps. 5. Heavy gauge extruded aluminum reflectors with high gloss reflective finish. Resists dents and corrosion. 6. 1/2 inch, threaded access hole for wiring conduit.  7. Units can be wired end to end in series.

Shipping and delivery Information