Hazardous Area Fluorescent Emerg. Light -C1D2 Groups & Class 2 Div - 4' 6 T8 lamps - 3000K & 5000K

LARSON ELECTRONICSSKU: PL3-HALS-EMG-48-6L-T8-3X3K.3X5K
filler

Precio:
Precio de venta$3,300.00

Descripción

Specifications / Additional Information
HALS-EMG-48-6L-T8-3X3K.3X5K Hazardous Area Ratings
NRTL Listed for United States & Canada Class 1 Division 2, Groups A, B, C, D
Lamp Type: Fluorescent Class 2 Division 2 Groups F,G
Dimensions: W-20 11/16" L-51 1/2 " H-5 5/16 " Class III
Weight: 8 Lbs IP65
Voltage: 120, 277, 347 & 480 Wet Area Suitable
Total Watts: 192 Watts NRTL Certified to UL 1598
Total Lumens: STD-T8 Bulbs 17,500 NRTL Certified to UL 44 
Luminous Efficacy STD-T8 Bulbs: 92 Lm/W Switch Leg for Powering Light On/Off
Lamp Life Expectancy: STD-T8 Bulbs 30,000 Hours
Color Temp: (3) 3000K Bulbs & (3) 5000K Bulbs
Ambient Operating Temp Range: -30° C to +70° C
Operating Temp Range: T5-T4C Rated Toll Free: 1-800-369-6671
Battery Backup: 90 Minute Runtime 900 Lumens Intl: 1-214-616-6180
Surface Mounting: Surface Bracket Standard - Pendant Optionals Fax: 1-903-498-6433
Wiring Hub: 1/2inch threaded 2-On Top 2-On Ends E-mail: 
' Product Overview '
Made in the USA The Larson Electronics HALS-EMG-48-6L-T8-3X3K.3X5K Hazardous Area Fluorescent Light Fixture is NRTL Listed for United States and Canada Class 1 Division 2 Groups A, B, C and D - NRTL Certified to UL 1598 listed and ideal for use in industrial hazardous locations where wet conditions and chemical/petrochemical vapors may be encountered. This fluorescent consists of three bulbs with a 3000K color temprature and three bulbs with a 5000K color temperature, creating a full spectrum. ***PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO THIS HAZARDOUS LOCATION LIGHT FIXTURE*** The HALS-EMG-48-6L-T8-3X3K.3X5K fixture is a 4 foot long, 6 lamp, Class 1 Division 2 Groups A, B, C and D hazardous area fluorescent light and a good choice for use in industrial applications and wet areas, and provides operators in hazardous locations with a very durable, reliable and affordable lighting solution for open areas where flammable chemicals and vapors may occasionally be present. This fixture is T4C temperature rated and comes standard with 6 F32/741 T-8 bulbs. The housing on this unit is constructed of powder coated 18 gauge steel for durability and contains a hinged reflector and ballast tray for easy and safe servicing. The lamps are held in place by spring loaded sockets and protected by a hinged glass door with a 3/16” tempered glass lens which is secured with four turn latches. This fixture is multi-voltage capable and can be operated with voltages of 120, 277, 347 & 480 VAC. This fixture is IP65 rated water and dustproof and carries UL and Canada approvals for wet and marine locations. This fixture also features multiple 1/2 NPT wiring hubs with two located on top of the fixture at two more located at each end, allowing operators to through-wire multiple units in series or mount the unit with wire through conduit pendant mounts. The HALS-EMG-48-6L-T8-3X3K.3X5K features three 3000K T8 bulbs and three 5000K T8 bulbs, which are situated in an alternating configuration to create a full color spectrum of light. This fluorescent light works, mounts and is wired like our HALS-EMG-48-6L-T8-3X3K.3X5K hazardous area fluorescent light fixtures. The main difference is that we attach an extra Bodine ballast box to the unit that adds emergency light functionality to the fixture. This explosion proof emergency light will run the standard 90 minutes after power is lost. The light recharges the battery once electrical power is restored. Standard configuration includes a single emergency ballast that will run a single lamp at 900 lumens for 90 minutes. For an additional charge, a second ballast can be added to run a second lamp for 1800 total lumens output for 90 minutes. The battery backup unit includes a switched leg for turning the light fixture on/off without kicking the unit into emergency mode. Standard Surface Mount Brackets: Each surface mounting bracket is attached on each end of the light and allows the operator to adjust the angle of the entire fixture. Pendant mounts are available for operators who wish to mount these fixtures away from the ceiling surface. Suggested Applications: Aircraft maintenance, Oil drilling rigs, Refineries, Solvent and cleaning areas, Chemical manufacturing, Waste treatment plants, Gas processing plants.
Made in USA Quality
1. Each unit dialectically tested. 2. Fixture arrives assembled and lamped to reduce installation time and cost. Adjustable mounting brackets enable the operator to choose any mounting angle for the fixture, where other models may only offer one or three choices. 3. Fixture housing constructed of white powder coated 18 gauge steel. 4. Relamping done via 4 turn latches, which enable the operator to unlatch the hinged door and access the lamps. 5. Heavy gauge hinged reflector with high gloss reflective finish. Resists dents and corrosion. 6. Multiple 1/2 inch, threaded NPT access holes for through wiring. 7. Units can be wired end to end in series.