Descripción
PuriLite suggests you place an order directly with us for large Larson orders due to the potential customization requirements. Please call us at 1(647) 254-9757 to place your order. If you prefer to place your order online, a PuriLite agent will be in touch with you to discuss any custom options.
This unit is Made In USA - Manufactured in Texas
The IND-HVAC-DTW-UVC-R1-SS-12-2L-220V-10C from Larson Electronics is a Air Duct Disinfection System that works to disinfect air moving through a duct system via germicidal ultraviolet (UV) rays. This unit helps to control the spread of airborne cold and flue virus as well as other airborne transmitted disease. This anodized aluminum air duct disinfection system features a pair of 10 watt UV bulbs that each produce 3.6 watts (7.2W total) of UV output at a wavelength of 254nm. The IND-HVAC-DTW-UVC-R1-SS-12-2L-220V-10C is equipped with 10' of 16/3 SOOW cable terminated in a 220 V cord cap and is designed to be mounted inside an air duct. It operates on 220 V AC current.
*Please note: This product produces UV light. Make sure to follow all safety guidelines and protocols found in the user manual.
*
The IND-HVAC-DTW-UVC-R1-SS-12-2L-220V-10C is a powerful sanitation solution for industrial sites and commercial facilities. Equipped with a pair of UVC fluorescent lamps, this system offers 7.2 total watts of UV output at a wavelength of 254nm. The lights have an expected lifespan of 8,000+ hours and emit a flood beam pattern. The IND-HVAC-DTW-UVC-R1-SS-12-2L-220V-10C can be used continuously in air ducts such as those found in HVAC systems.
Operation:
This UV air duct disinfection system projects ultraviolet rays inside the air duct it is mounted in. The air flowing through the duct that passes through the UV rays is then sanitized. Bacteria and viruses present in the air that passes through the UV rays produced by the fixture are destroyed. The air moving through the duct is constantly being purified as it flows through the UV rays being produced by the fixture.
Construction:
The enclosure of the IND-HVAC-DTW-UVC-R1-SS-12-2L-220V-10C is built from 304 stainless steel. In-Operation and Replace-Lamp indicator lamps allows for operators to check the status of the UV bulb(s) without removing the fixture from the air duct or being exposed to harmful UV radiation.
L6-15 Twist Lock Plug
UK BS1363 Straight Blade Plug
Intl Schuko 2-Pin Plug
Flying Leads / Pigtail Wires
Wiring/Plug:
This unit is equipped with 10 feet of 16/3 chemical and abrasion resistant SOOW cord that is fitted with an industrial grade cord cap for easy connection to outlets. Plug options include standard NEMA 6-15 15 amp straight blade plug, standard NEMA 6-20 20 amp straight blade plug, NEMA L6-15 15 amp twist lock plug, NEMA L6-20 20 amp twist lock plug, British BS1363 (Type G plug) 13 amp fused 3-blade plug for United Kingdom outlets, a two pin 16 amp rated Schuko plug (Type F, CEE 7/4 plug) with ground contact and socket for European outlets up to 250V, or a BS546 (Type M, CEE 3-pin 15 amp rated plug for Indian and South African outlets. Alternatively, we can provide flying leads with no plug for hard wire applications or for operators who prefer to wire in user provided cord caps. Please choose pigtail option below for flying leads with no plug.
Mounting:
The IND-HVAC-DTW-UVC-R1-SS-12-2L-220V-10C is designed to be mounted inside an air duct. The system is mounted in a partial internal style with the bulb(s) being mounted inside of the air duct and the electronics mounted on the outside of the duct.
Note on Environment:
Sunlight and visible light fixtures do not impact the effectiveness of the disinfecting on this UVC sanitation product. Metal halide, high pressure sodium, fluorescent, and LED light fixtures can be left on. The UV radiation emitted from this product is not disrupted by any type of lighting in the environment. Put simply, NO it DOES NOT need to be dark in the area you plan to disinfect. The UV radiation is harmful to the eyes and skin, and that is why you should not be in the area while it is in operation. Please see user manual for additional safety information.
Applications:
This ultraviolet UV air duct disinfection system can be used to continuously disinfect air of mold, allergens, airborne bacteria, viruses, and germs. The IND-HVAC-DTW-UVC-R1-SS-12-2L-220V-10C is ideal for use in restaurants, hospitals, clinics, laboratories, nursing homes, schools, food processing facilities, office buildings, conference rooms, universities, clean rooms, and many more.
Larson Electronics is a manufacturer and as such can build stationary and portable transformer systems to your Specifications. Although we carry several models of power distribution transformer systems, we can deliver custom ordered units almost as quickly as our prebuilt units. If this model does not meet your needs, please contact us at 1(647) 254-9757 or
Contact info@purilite.ca
to discuss your specific requirements.
Specifications
Lamp Technology: UV-C Fluorescent
Exterior Housing Dimensions: 8.00"H x 5-19/32"W x 2-7/8"D
Lamp Extension (into duct): 13.5"
Weight: -
Voltage: 220V AC, 50/60 Hz
Wattage: 10W Per Lamp
Total Watts: 20W
UV Output: 3.6W per lamp 7.2W
Total UV Output: 7.2W
Irrdiance (single lamp): 30 uW/cm2 @ 1 meter
Expected Lifespan: 8,000+ Hours
UV Wavelength: 254nm peak
Lamp Base: G13 (Medium Bi-Pin)
Replacement Lamp: FRL-12-1X-T8-10W-UV-C
Beam Angle: 360º
Light Configuration: Flood
Amps: 0.21A @ 220V
Ambient Operating Temp Range: -
Materials: 304 Stainless Steel Enclosure
Indicator Lights: Operational Light (confirms on) and Replace Lamp (lamp no longer functional) indicator lamps
Mounting: Partial Internal Air Duct Mount
Wiring: 10' 16/3 SOOW Cord w/ 220V Cord Cap
Cord Cap: NEMA 6-15, NEMA 6-20, NEMA L6-15, NEMA L6-20, BS1363 (Type G), Schuko (Type F, CEE 7/4), BS546 (Type M), or Pigtail
This unit is Made In USA - Manufactured in Texas
The IND-HVAC-DTW-UVC-R1-SS-12-2L-220V-10C from Larson Electronics is a Air Duct Disinfection System that works to disinfect air moving through a duct system via germicidal ultraviolet (UV) rays. This unit helps to control the spread of airborne cold and flue virus as well as other airborne transmitted disease. This anodized aluminum air duct disinfection system features a pair of 10 watt UV bulbs that each produce 3.6 watts (7.2W total) of UV output at a wavelength of 254nm. The IND-HVAC-DTW-UVC-R1-SS-12-2L-220V-10C is equipped with 10' of 16/3 SOOW cable terminated in a 220 V cord cap and is designed to be mounted inside an air duct. It operates on 220 V AC current.
*Please note: This product produces UV light. Make sure to follow all safety guidelines and protocols found in the user manual.
*
The IND-HVAC-DTW-UVC-R1-SS-12-2L-220V-10C is a powerful sanitation solution for industrial sites and commercial facilities. Equipped with a pair of UVC fluorescent lamps, this system offers 7.2 total watts of UV output at a wavelength of 254nm. The lights have an expected lifespan of 8,000+ hours and emit a flood beam pattern. The IND-HVAC-DTW-UVC-R1-SS-12-2L-220V-10C can be used continuously in air ducts such as those found in HVAC systems.
Operation:
This UV air duct disinfection system projects ultraviolet rays inside the air duct it is mounted in. The air flowing through the duct that passes through the UV rays is then sanitized. Bacteria and viruses present in the air that passes through the UV rays produced by the fixture are destroyed. The air moving through the duct is constantly being purified as it flows through the UV rays being produced by the fixture.
Construction:
The enclosure of the IND-HVAC-DTW-UVC-R1-SS-12-2L-220V-10C is built from 304 stainless steel. In-Operation and Replace-Lamp indicator lamps allows for operators to check the status of the UV bulb(s) without removing the fixture from the air duct or being exposed to harmful UV radiation.
L6-15 Twist Lock Plug
UK BS1363 Straight Blade Plug
Intl Schuko 2-Pin Plug
Flying Leads / Pigtail Wires
Wiring/Plug:
This unit is equipped with 10 feet of 16/3 chemical and abrasion resistant SOOW cord that is fitted with an industrial grade cord cap for easy connection to outlets. Plug options include standard NEMA 6-15 15 amp straight blade plug, standard NEMA 6-20 20 amp straight blade plug, NEMA L6-15 15 amp twist lock plug, NEMA L6-20 20 amp twist lock plug, British BS1363 (Type G plug) 13 amp fused 3-blade plug for United Kingdom outlets, a two pin 16 amp rated Schuko plug (Type F, CEE 7/4 plug) with ground contact and socket for European outlets up to 250V, or a BS546 (Type M, CEE 3-pin 15 amp rated plug for Indian and South African outlets. Alternatively, we can provide flying leads with no plug for hard wire applications or for operators who prefer to wire in user provided cord caps. Please choose pigtail option below for flying leads with no plug.
Mounting:
The IND-HVAC-DTW-UVC-R1-SS-12-2L-220V-10C is designed to be mounted inside an air duct. The system is mounted in a partial internal style with the bulb(s) being mounted inside of the air duct and the electronics mounted on the outside of the duct.
Note on Environment:
Sunlight and visible light fixtures do not impact the effectiveness of the disinfecting on this UVC sanitation product. Metal halide, high pressure sodium, fluorescent, and LED light fixtures can be left on. The UV radiation emitted from this product is not disrupted by any type of lighting in the environment. Put simply, NO it DOES NOT need to be dark in the area you plan to disinfect. The UV radiation is harmful to the eyes and skin, and that is why you should not be in the area while it is in operation. Please see user manual for additional safety information.
Applications:
This ultraviolet UV air duct disinfection system can be used to continuously disinfect air of mold, allergens, airborne bacteria, viruses, and germs. The IND-HVAC-DTW-UVC-R1-SS-12-2L-220V-10C is ideal for use in restaurants, hospitals, clinics, laboratories, nursing homes, schools, food processing facilities, office buildings, conference rooms, universities, clean rooms, and many more.
Larson Electronics is a manufacturer and as such can build stationary and portable transformer systems to your Specifications. Although we carry several models of power distribution transformer systems, we can deliver custom ordered units almost as quickly as our prebuilt units. If this model does not meet your needs, please contact us at 1(647) 254-9757 or
Contact info@purilite.ca
to discuss your specific requirements.
Specifications
Lamp Technology: UV-C Fluorescent
Exterior Housing Dimensions: 8.00"H x 5-19/32"W x 2-7/8"D
Lamp Extension (into duct): 13.5"
Weight: -
Voltage: 220V AC, 50/60 Hz
Wattage: 10W Per Lamp
Total Watts: 20W
UV Output: 3.6W per lamp 7.2W
Total UV Output: 7.2W
Irrdiance (single lamp): 30 uW/cm2 @ 1 meter
Expected Lifespan: 8,000+ Hours
UV Wavelength: 254nm peak
Lamp Base: G13 (Medium Bi-Pin)
Replacement Lamp: FRL-12-1X-T8-10W-UV-C
Beam Angle: 360º
Light Configuration: Flood
Amps: 0.21A @ 220V
Ambient Operating Temp Range: -
Materials: 304 Stainless Steel Enclosure
Indicator Lights: Operational Light (confirms on) and Replace Lamp (lamp no longer functional) indicator lamps
Mounting: Partial Internal Air Duct Mount
Wiring: 10' 16/3 SOOW Cord w/ 220V Cord Cap
Cord Cap: NEMA 6-15, NEMA 6-20, NEMA L6-15, NEMA L6-20, BS1363 (Type G), Schuko (Type F, CEE 7/4), BS546 (Type M), or Pigtail
Shipping and delivery Information
The PuriLite Peace of Mind 30-day money back guarantee
Payment
Su información de pago se procesa de forma segura. No almacenamos los detalles de la tarjeta de crédito ni tenemos acceso a la información de su tarjeta de crédito.