Mobile UV Hazardous Location Disinfection Cabinet - Kills 99% of Viruses - 120V - (20) UV Lamps, Timer - (5) Mesh Wire Shelves - Type Z Purge System for C1D2 Use

LARSON ELECTRONICSSKU: PL3-HAL-TBL-BX-AEP.Z-18.18.30-5XH-WC-25C-120V-EPP
filler

Prix:
Prix réduit$31,783.99

Description

Specifications / Additional Information
This unit is Made In USA - Manufactured in Texas
HAL-TBL-BX-AEP.Z-18.18.30-5XH-WC-25C-120V-EPP Hazardous Location Single-door UV Cabinet Ratings/Features
Lamp Technology: UV-C Fluorescent Listed for Use in United States & Canada
Lamp Qty: (20) 18" UV Lamps - (4) UV Lamps per Shelf Class I, Division 2, Groups A, B, C, D
Shelf Dimensions: (5) 18" x 18" Mesh Wire Shelves Class I, Zone 2, Groups IIA, IIB and IIC
Shelve Clearance: 6" NRTL Listed to NFPA 496
Weight: 145 lbs NRTL Listed to UL 508A
Voltage: 120 V, 60 Hz NRTL Listed to CSA C22.2 No. 14
Total Watts: - Short-wave Germicidal Light
Single-lamp Watts: - Kills 99% of Viruses and Other Germs
Total UV Output: - EPA Reg. No 98409-1
Single-lamp UV Output: - EPA Est. No. 98409-TX-1
Expected Lifespan: 8,000+ Hours
UV Wavelength: UV-C, 200nm - 280nm (253.7 nm)
Lamp Type: -
Lamp Base: -
Replacement Lamp: -
Beam Angle: 360º
Light Configuration: Flood
Surface Reflectance: Stainless Steel Interior Finish
Timer: Adjustable Internal Timer, 5-minute Factory Setting
Activation: Push Button  
Safety: Yellow Indicator Light and Safety Kill Switch on Door  
Amps: -  
Minimum Airflow Requirement: 80 PSI  
Maximum Airflow Requirement: 120 PSI  
Ambient Operating Temp Range: - Special Orders - Requirements
Materials: -
Lens Material: -
Mounting: Mobile Flat Base w/ Handle and (2) 8" Swivel-locking Casters [Front], (2) 8" Stationary Casters [Back]
Wiring: 25' 16/3 SOOW Cord w/ Explosion Proof Cord Cap
Cord Cap: 5-15 Straight Blade or 5-20 Straight Blade
***PLEASE NOTE: UV-C light can cause temporary or permanent loss of vision, and temporary acute redness or ulceration (mild to severe sunburn) to exposed skin. To prevent exposure, do not operate the device in any application that allows UV-C light to be visible during operation. NEVER LOOK DIRECTLY AT THE BULB OR DISINFECTING TARGET ZONE. DO NOT touch bulb with bare hands. The oils in your skin will damage the lamp. Fingerprints will result in reduced performance and significantly reduce the lifespan of the lamp unless they are removed with alcohol. Please read instruction manual for UV safety requirements before operating.***
' Product Overview '
function MM_openBrWindow(theURL,winName,features) { //v2.0 window.open(theURL,winName,features); }
This unit is Made In USA - Manufactured in Texas The HAL-TBL-BX-AEP.Z-18.18.30-5XH-WC-25C-120V-EPP from Larson Electronics is a Hazardous Location Mobile UV Disinfection Cabinet that uses a Type Z continuous flow purge system and is for cleaning several handheld devices quickly and simultaneously. Equipped with twenty 18" UV lamps, the unit offers UV-C output at a range of 200nm - 280nm (253.7nm). There are five 18" x 18" mesh wire shelves for holding different types of equipment. The single-door UV oven has highly visible indicator lights for safe operation and comes with an internal timer. The disinfection cabinet contains four 8" casters at the bottom of the unit. *Please note: This product produces UV light. Make sure to follow all safety guidelines and protocols found in the user manual. UVC light in the proper setting kills up to 99.9% of viruses, mold, spores, and bacteria. * The HAL-TBL-BX-AEP.Z-18.18.30-5XH-WC-25C-120V-EPP is a powerful sanitation solution for cleaning compact and handheld equipment in busy work sites. This UV oven is safe to use in Class I Division 2 hazardous location. Equipped with twenty 18" UVC fluorescent lamps, this system offers UV output, within the 200nm - 280nm UV-C range (253.7 nm). The lights have an expected lifespan of 8,000+ hours and emit a flood beam pattern with 360 degrees of coverage. A stainless steel interior finish promotes UV light distribution. Inside the box, there are five 18" x 18" mesh wire shelves with 6" clearance for holding different types of devices for sanitation. Each shelf has four lamps on every wall including the door to ensures maximum exposure. This hazardous location UV cabinet turns off automatically when the door is open. A yellow indicator light turns on when the unit is in use to safely notify the operator about ongoing sanitation. With a recommended 5-minute exposure time at full capacity, multiple UV boxes can be purchased to clean several devices at the same time. Operators may access an external timer (set at 5 minutes from the factory) on the box to ensure the recommended duration of exposure is met every session. The UV light can disinfect over 99% of bacteria, viruses, mold, and spores. Voltage: The HAL-TBL-BX-AEP.Z-18.18.30-5XH-WC-25C-120V-EPP operates on 120 V AC, 60 Hz. Purge and Pressurization System: The HAL-TBL-BX-AEP.Z-18.18.30-5XH-WC-25C-120V-EPP uses a Type Z continuous flow purge and pressurization system that makes it safe to use within Class I Division 2 hazardous locations. In a purge and pressurization system, any hazardous gas is purged from the enclosure through a series of complete air exchanges. The enclosure is then pressurized to prevent the entry of any hazardous gas or dust from entering the enclosure. In a continuous flow purge system, like the one used in this UV oven, a constant flow of air following the purge is used to maintain internal pressure. The HAL-TBL-BX-AEP.Z-18.18.30-5XH-WC-25C-120V-EPP features a Type Z continuous flow purge system. A Type Z system requires a minimum of 25 Pa for internal pressure. The other main feature of a Type Z system is that power to the unit is automatically disconnected if a drop in pressure below the minimum occurs or any other loss of pressure occurs. This means that it then must go through the purge and pressurization process successfully again before operation can resume within the hazardous area. Operation: The HAL-TBL-BX-AEP.Z-18.18.30-5XH-WC-25C-120V-EPP is equipped with a C1D1 rated push button for power and a C1D1 rated power indicator light on the outside of the unit. A timer is installed on the inside of the enclosure. The timer keeps the UV lamps running for the recommended amount of time to disinfect the desired items. To use the UV oven, the operator places the items in the racks on the inside of the oven, closes the gasketed door, secures the stainless steel draw latches, and pushes the power button. The unit then purges the enclosure and pressurizes it. Once pressurization is complete, power is provided to the timer. The UV lamps then power up and stay on throughout disinfection. This entire process must be repeated every time the lid is opened or pressure is otherwise lost.
Click Photos to Enlarge
5-15 Straight Blade Plug 5-20 Straight Blade Plug
Wiring & Plug: This hazardous location UV oven is equipped with 25 feet of 16/3 chemical and abrasion resistant SOOW cord that is fitted with an explosion proof cord cap for easy connection to explosion proof outlets. Plug options include a 5-15 15 amp straight blade plug for use with 120 V explosion proof outlets or a 5-20 20 amp straight blade plug for use with 120 V explosion proof outlets. **PLEASE NOTE** voltage ratings on plugs and outlets are MAXIMUM voltage. For low voltage applications, proper voltage must be applied to the outlet or damage to the light fixture will occur. Mount: This hazardous location UV sanitation device has a flat base with four, 8" casters (two swivel-locking casters at the front and two stationary casters at the back) for seamless mobility and transportation, including over rough surfaces. An accessible handle at the back of the cabinet allows operators to move the unit around the site. We sell mounting lugs for permanent installations if needed. Note on Environment: Sunlight and visible light fixtures do not impact the effectiveness of the disinfecting on this UVC sanitation product. Metal halide, high pressure sodium, fluorescent, and LED light fixtures can be left on. The UV radiation emitted from this product is not disrupted by any type of lighting in the environment. Put simply, NO it DOES NOT need to be dark in the area you plan to disinfect. The UV radiation is harmful to the eyes and skin, and that is why you should not be in the area while it is in operation. Please see user manual for additional safety information. Suggested Applications: Sanitation, disinfection, warehouses, retail stores, event venues, commercial operations, POS, handheld devices and more; kills 99% of viruses, bacteria, mold and spores.

Shipping and delivery Information

Payment

American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Vos informations de paiement sont gérées de manière sécurisée. Nous ne stockons ni ne pouvons récupérer votre numéro de carte bancaire.

You may also like

Recently viewed