Safety: Yellow Indicator Light and Safety Kill Switch on Door
Â
Capacity: Up to 7 Laptops or Chromebooks; OR 20+ iPads or Tablets, Scanners, Video Games and Controllers; OR 50+ Smartphones, Video Games and Other Similar Size Items; 30+ Masks
Â
UV Treatment Time: 3 Minutes
Â
Amps: 11.16A @ 120V
Â
Ambient Operating Temp Range: -
Â
Materials: -
Special Orders - Requirements
Lens Material: -
Mounting: Mobile Flat Base w/ Handle and (2) 8" Swivel-locking Casters [Front], (2) 8" Stationary Casters [Back]
Rack Components: (4) Shelves, Hooks for Masks
Wiring: 25' 16/3 SOOW Cord w/ Cord Cap
Cord Cap: 5-15, 5-20, L5-15, L5-20, or Pigtail
***PLEASE NOTE: NEVER LOOK DIRECTLY AT THE BULB OR DISINFECTING TARGET ZONE. DO NOT touch bulb with bare hands. The oils in your skin will damage the lamp. Fingerprints will result in reduced performance and significantly reduce the lifespan of the lamp unless they are removed with alcohol. Please read instruction manual for UV safety requirements before operating.***
'
Product Overview
'
This unit is Made In USA - Manufactured in Texas
The Larson Electronics IND-TBL-BX-R15-FUVC-EXT-24.18.60-M1-WC-25C-120V is a UV Disinfection Equipment Cabinet which can disinfect 99.99% of viruses, human corona viruses (including SARS-CoV-2 that causes COVID-19), bacteria, mold and spores found on devices. Designed for schools and occupied areas, the unit is equipped with ten mercury-free far-UV 222nm excimer lamps, which are eye and skin safe for humans. This user-friendly disinfection box has the capacity to clean up to 7 laptops or chromebooks; OR 20+ iPads or tablets, scanners, video games and controllers; OR 50+ smartphones, video games and other similar size items, as well as 30+ masks via accessible top-located hooks. The chemical/toxin-free sanitation process takes 3 minutes to complete. This system features four casters for seamless mobility around campuses and facilities.
*Please note: This product produces far-UVC light. Make sure to follow all safety guidelines and protocols found in the user manual. UVC light in the proper setting kills up to 99.99% of viruses, human corona viruses (including SARS-CoV-2 that causes COVID-19), bacteria, mold and spores. *
The IND-TBL-BX-R15-FUVC-EXT-24.18.60-M1-WC-25C-120V is a powerful, eye and skin safe sanitation solution for schools, campuses and occupied areas. Equipped with ten far-UV excimer lamps, this system offers 222nm UV output during use. The mercury-free lights have an expected lifespan of 10,000+ hours and emit a flood beam pattern with 360 degrees of coverage. A stainless steel interior finish promotes UV light distribution. The lights take on the following configuration inside the UV cabinet: (1) 90-watt 18" lamp at the top, (2) 145-watt 34" lamps on the left side, (2) 145-watt 34" lamps on the right side, (2) 145-watt 34" lamps on the back side of the door, (2) 145-watt 34" lamps on the back side and (1) 90-watt 18" lamp at the base. This UV sanitation unit has the capacity to disinfect up to 7 laptops or chromebooks; OR 20+ iPads or tablets, scanners, video games and controllers; OR 50+ smartphones, video games and other similar size items, as well as 30+ masks via accessible top-located hooks.
Operation: The UV disinfection cabinet is easy to use and user friendly for all staff. Instructions for operation are available on a printed label located on the side of the unit. This UV cabinet turns off automatically when the door is open. A yellow indicator light turns on when the unit is in use to safely notify the operator about ongoing sanitation. Adhering to the 3-minute exposure time at full capacity, multiple UV cabinets can be purchased to clean several devices and masks at the same time. Operators may access an external timer on the cabinet to ensure the recommended duration of exposure is met every session. The UV lights can disinfect over 99.99% of viruses, human corona viruses (including SARS-CoV-2 that causes COVID-19), bacteria, mold and spores.
Far-UV 222 nm light is considered to be eye and skin safe for humans, allowing the lamps to be used in occupied areas safely with minimum risk. The 222 nm wavelength does not penetrate the cornea of the eye and cannot impose corneal impairment. Additionally, this UV band is blocked by the top layer of skin (stratum corneum) which protects underlying cells from damage. Exposure to far-UV 222 nm lamp does not cause skin inflammation or swelling. Due to these safety benefits, extensive protective clothing is not required when using this type of sanitation light in occupied areas.
Benefits of Excimer Far UV Lamps: When it comes to Far-UV lamps, there are few options in the skin-safe and eye-safe wavelengths. Similar to LED lamps, excimer lamps provide “instant-on†startup, and do not require a warm-up period; excimer lamps are at 100% peak output when switched on. Most lamp technologies that do product UVC use mercury in the manufacturing process. Excimer lamps have ZERO mercury, making them more environmentally friendly. Excimer lamps can be tuned to specific wavelengths (222nm wavelength for this product) and produce no harmful UVC radiation or wasteful visible light and infrared light. Excimer lamps are more efficient at converting electricity (input power) into UV irradiance, which reduces the heat output from excimer lamps over other technologies. Fluorescent, amalgam, low-pressure mercury, and high-pressure mercury lamps do not product as tight of a wavelength and generate more heat, both of which wastes energy for the UV sanitation application. Excimer lamps have a higher average UV irradiance per square inch and have a higher photon emission over other lamp technologies. Being safe for use in occupied areas, instant-on power, mercury free, higher UV output, and low heat output make Far-UV excimer lamps the preferred choice for UV sanitation and disinfecting applications.
Germicidal excimer lamps emit far-UV 222 nm light that is generated by specific excimer molecules. The far-UV lights come with an expected lifespan of 10,000+ hours. This gas-filled emitter is energy efficient and offers cool operation. A power supply is typically utilized with the non-toxic lamp to ensure consistent UV output. The sanitation light, which is suitable for use in occupied areas, features instant start capabilities.
Voltage: The IND-TBL-BX-R15-FUVC-EXT-24.18.60-M1-WC-25C-120V operates on 120V AC, 60Hz.
Click Photos to Enlarge
5-15 Straight Blade Plug
15 Amp / 125V Rated
L5-15 Twist Lock Plug
15 Amp / 125V Rated
Flying Leads / Pigtail Wires
Wiring/Plug: This UV decontamination cabinet is equipped with 25 feet of 16/3 chemical and abrasion resistant SOOW cord that is fitted with an industrial grade cord cap for easy connection to common wall outlets. Plug options include standard 5-15 15 amp straight blade plug for 110V wall outlets with ground, NEMA L5-15 15 amp twist lock plug for 125V twist lock outlets, standard 5-20 20 amp straight blade plug for 110V wall outlets with ground or or NEMA L5-20 20 amp twist lock plug for 125V twist lock outlets. Alternatively, we can provide flying leads with no plug for hard wire applications or for operators who prefer to wire in user provided cord caps. Please choose pigtail option below for flying leads with no plug.
Mount: The UV sanitation device has a flat base with four, 8" casters (two swivel-locking casters at the front and two stationary casters at the back) for seamless transportation over finished surfaces and rough surfaces. An accessible handle at the back of the cabinet allows operators to move the unit around the site. Regardless of the weight, the heavy-duty casters and handle allow the UV cabinet to be easily moved by one person. This sanitation system fits through standard 36" doorways. We sell mounting lugs for permanent installations if needed.
Inside the UV cabinet, four racks are available for keeping various items segregated or upright during sanitation. Individuals may also access top-located hooks for cleaning 30+ masks.
Note on Environment: Sunlight and visible light fixtures do not impact the effectiveness of the disinfecting on this UVC sanitation product. Metal halide, high pressure sodium, fluorescent, and LED light fixtures can be left on. The UV radiation emitted from this product is not disrupted by any type of lighting in the environment. Put simply, NO it DOES NOT need to be dark in the area you plan to disinfect. Please see user manual for additional safety information.
Suggested Applications: Sanitation, disinfection, schools, education centers, libraries, classrooms, offices, lobbies, occupied areas, industrial parks, medical centers and more. Eliminates 99.99% of viruses, human corona viruses (including SARS-CoV-2 that causes COVID-19), bacteria, mold and spores.
Shipping and delivery Information
Estimated delivery times range from 1 to 3 weeks, depending on your location, the product ordered and stock availability. External factors such as courier network disruptions can also impact delivery timelines. PuriLite strives to ship your purchase in the shortest possible time using industry standard courier services.
For any questions related to shipping and delivery, please call +1-647-254-9757, email us at info@purilite.ca or chat with us by clicking on the chat icon at the bottom right of this page.
Payment
Vos informations de paiement sont gérées de manière sécurisée. Nous ne stockons ni ne pouvons récupérer votre numéro de carte bancaire.
Politique de remboursement
Return & Refund Policy
For All non-Larson Products If you are not satisfied with a product, contact us by emailing or call 1-844-787-LITE within 30 days of receipt. A refund may be arranged excluding freight charges upon inspection. Returned merchandise must be shipped in original packaging, freight prepaid, unused, and in resalable condition, and are subject to 25% restocking fee. PuriLite inspects all returns and reserves the right to refuse credits on damaged, used or non-resalable items. Your only obligation is the freight charge and restocking fee, provided your return is complete with original packaging, all documentation, warranty cards, cables etc. PuriLite reserves the right to authorize product returns after 30 days have passed from the order date. If the product is accepted after this period, it is subject to a 25% restocking fee and credit will be issued toward future purchases only.
Shipping and handling charges are non-refundable for all returns. The customer may also be responsible for return shipping charges, insurance and shipment tracking for returned merchandise.
Once you place an order, the following products are non-returnable: custom-cut, customer built or special order items (such as matting, slings, cranes, prefab offices, buildings, mezzanines, assembled lockers and regularly stocked items such as generators, pressure washers, water and trash pumps, snow throwers, radio headsets, striping paint, line stripers, floor care machines, vacuums, custom fabric chairs, forklifts) your order is considered non-cancellable and any custom-cut, customer built or special order items purchased by you are also non-returnable. Consumable style bulbs or lamps are not returnable. There are no returns on any medical and/or sanitizing products for obvious safety reasons. This includes PPE (including masks), tests, thermometers, sprayers and UVC lighting of any kind (portable and surface).
Leased and hazardous items are also non-returnable. Contact customer service for a complete list of applicable products.
Larson product return policy Every order is tested prior to shipping. The product is tested before it is put into the shipping box, crate, pallet, etc. Larson take pictures and videos of every product for every order being shipped, and store these pictures and videos with the order number in our system. Because of the complexity of some of our products, we have a very limited return policy.
For safety reasons, we do not accept returns on any hazardous location, explosion proof or intrinsically safe products. Once these products leave the factory, we cannot be sure what happens to them. We must re-build and re-certify the units to specification to ensure that the next customer receives an item that is safe to use. This is cost prohibitive. For that reason, we do not accept returns on classified products. We do not accept returns on transformers, phase converters, or frequency converters. In order to install one of the aforementioned products, typically customers will modify the product (i.e. penetrate the housing to make connections, punch out knockouts, remove or damage tinning on lead wires during installation). Because we video test every unit before it ships to ensure the unit operates as described, we know when they leave here the units are operationally functional and meet the output voltage when supplied with the input voltage per the product specification. To be clear, we do not accept returns on these items under any circumstances for these reasons.
Products that are not addressed in the above two conditions must be returned in new, unused condition.
Below are some additional considerations:
Electrical/electronic parts are easily damaged by improper installation or testing. Because electronics are very sensitive to voltage overloads, it does not take much of a voltage spike to ruin a component. Because of this risk, all electrical products returned will undergo electrical testing and assessed a testing fee. This fee will be subtracted from the final return value.
Consumable style bulbs or lamps are not returnable.
Products that contain emergency backup components are subject to very narrow warranty terms and do not qualify for return. For customer convenience, we engage the battery pack prior to shipping all emergency backup products. Many times, particularly with hazardous location rated products, the battery packs are difficult to access and the customer generally plans to install the units shortly after receipt of the shipment. Battery backup components using older technologies (Nicad, NIMH, SLA, etc) will fail quickly if they do not maintain valid grid tie support. In other words, the batteries must receive a consistent maintained charge to perpetuate long lifespans. Battery backup products that are shelved (not installed) for periods greater than 3 weeks will likely fail and need replacement sooner. This replacement will not be covered under warranty. This can also occur is the units are installed but the grid tie option is not connected correctly. Customers can specify that they do not want the battery pack to be engaged at the time of ordering if they plan to shelve the units for long periods of time prior to installation.
There are many products on the site and not all pictures depict the exact configuration of each product. Many products are custom built and/or built on demand. In some cases, products are designed and not sold immediately and rendering may be used. In all cases, the end product is built to the specification listed and the pictures shown may be close approximations. Pictures are more likely to be close approximations with more complex products, including transformers, power distribution systems, control systems, light tower systems and other highly customizable products. In no way does the approximation validate a potential return. We always build to the specification. If customers have questions, they should ask prior to purchase to clarify.
There are no returns on any medical and/or sanitizing products for obvious safety reasons. This includes PPE (including masks), tests, thermometers, sprayers and UVC lighting of any kind (portable and surface)
Many international orders, specialty orders and other complex build orders require prepayment in advance. This prepayment represents a commitment to the order. Cancelling the order will result in a deduction from the original amount paid if any refund is available, since an investment of time and money is typically required to acquire materials and prepare the order. While not all orders in this category require prepayment, cancellation fees may apply to other build orders as well. The percentage of the deduction is at Larson’s discretion but usually ranges from 30 to 50%.
How to Return For all returns, you can email us at sales@purilite.ca. You will need the invoice number in the subject line of the email. You can use one of your preferred carriers. Please note that for freight collect shipments, you are responsible for order tracking once the freight is loaded onto the truck. In addition, PuriLite Industrial cannot assist you with filing damage claims with your carrier.
All returns must be authorized by PuriLite. A Return Authorization Number must be obtained from PuriLite Customer Service Department, and the client must provide the Invoice number at the time of the request. The following conditions must be met. Failure to do so could result in refusal of a shipment by us.
At the time of the return, goods must be a stock item with PuriLite and the returned quantity must correspond to the quantity of the original packaging
Approval and shipping destination must be obtained from PuriLite before returning goods;
Goods must be returned to the appropriate location within 10 working days after receiving the return authorization number;
The return authorization number and invoice number must be identified on the return address label;
Goods must be in their original packaging, arrive undamaged and in resalable form
All returns are to be sent prepaid;
Specially ordered goods are non returnable – these products are identified with a part number beginning with a // on quotes and invoices.
Goods damaged in transit must be signed as damaged by the receiver and carrier at the time of receipt of goods in order to request credit from PuriLite.
PuriLite reserves the right to deny any Returns or Claims if the above conditions are not met.
Orders for products affected by x-factor events such as viral outbreaks and other extreme circumstances CANNOT be returned once shipped and billed.