36" UV Air Duct Disinfection 3-Lamp Fixture - UV-C - Destroys Airborne Bacteria & Viruses - 220V - 39.3W Total UV Output

LARSON ELECTRONICSSKU: PL3-IND-HVAC-DTW-UVC-R2-SS-36-3L-220V
filler

Prix:
Prix réduit$3,240.00

Description

Specifications / Additional Information
This unit is Made In USA - Manufactured in Texas
IND-HVAC-DTW-UVC-R2-SS-36-3L-220V UV Air Duct Disinfection System Ratings/Features
Lamp Technology: UV-C Fluorescent NRTL Listed to UL 508A
Exterior Housing Dimensions: 16-13/16"H x 8-1/8"W x 4-7/16"D NRTL Listed to CSA C22.2 No. 14
Depth (Inside Duct) for Partial Internal Mount: 39" T8 Bulb Shape
Weight: - Short-wave Germicidal Light
Voltage: 220V AC, 50/60 Hz Destroys Airborne Bacteria and Viruses
Wattage: 30W Per Lamp Non-Ozone Producing Germicidal UV Lamp
Total Watts: 90W EPA Reg. No 98409-1
UV Output: 13.1W per lamp EPA Est. No. 98409-TX-1
Total UV Output: 39.3W  
Irradiance (single lamp): 107 uW/cm2 @ 1 meter
Expected Lifespan: 8,000+ Hours
UV Wavelength: 254nm peak
Lamp Base: G13 (Medium Bi-Pin)
Replacement Lamp:FRL-36-1X-T8-30W-UV-C
Beam Angle: 360º
Light Configuration: Flood Special Orders - Requirements
Amps: 0.94A @ 220V
Ambient Operating Temp Range: -
Materials: 304 Stainless Steel Enclosure
Indicator Lights: Operational Light (confirms on) and Replace Lamp (lamp no longer functional) indicator lamps
Mounting: Partial Internal Duct Mount
***PLEASE NOTE: UV-C light can cause temporary or permanent loss of vision, and temporary acute redness or ulceration (mild to severe sunburn) to exposed skin. To prevent exposure, do not operate the device in any application that allows UV-C light to be visible during operation. NEVER LOOK DIRECTLY AT THE BULB OR DISINFECTING TARGET ZONE. DO NOT touch bulb with bare hands. The oils in your skin will damage the lamp. Fingerprints will result in reduced performance and significantly reduce the lifespan of the lamp unless they are removed with alcohol. Please read instruction manual for UV safety requirements before operating.***
' Product Overview '
This unit is Made In USA - Manufactured in Texas TheIND-HVAC-DTW-UVC-R2-SS-36-3L-220V from Larson Electronics is a Air Duct Disinfection System that works to disinfect air moving through a duct system via germicidal ultraviolet (UV) rays. This unit helps to control the spread of airborne cold and flue virus as well as other airborne transmitted disease. This anodized aluminum air duct disinfection system features three of 30 watt UV bulbs that each produce 13.1 watts (39.3W total) of UV output at a wavelength of 254nm. TheIND-HVAC-DTW-UVC-R2-SS-36-3L-220V is designed to be mounted inside an air duct and operates on 220V AC current. *Please note: This product produces UV light. Make sure to follow all safety guidelines and protocols found in the user manual.* TheIND-HVAC-DTW-UVC-R2-SS-36-3L-220V is a powerful sanitation solution for industrial sites and commercial facilities. Equipped with three UVC fluorescent lamps, this system offers 39.3 total watts of UV output at a wavelength of 254nm. The lights have an expected lifespan of 8,000+ hours and emit a flood beam pattern. TheIND-HVAC-DTW-UVC-R2-SS-36-3L-220V can be used continuously in air ducts such as those found in HVAC systems. Operation: This UV air duct disinfection system projects ultraviolet rays inside the air duct it is mounted in. The air flowing through the duct that passes through the UV rays is then sanitized. Bacteria and viruses present in the air that passes through the UV rays produced by the fixture are destroyed. The air moving through the duct is constantly being purified as it flows through the UV rays being produced by the fixture. Construction: The enclosure of theIND-HVAC-DTW-UVC-R2-SS-36-3L-220V is built from 304 stainless steel. In-Operation and Replace-Lamp indicator lamps allows for operators to check the status of the UV bulb(s) without removing the fixture from the air duct or being exposed to harmful UV radiation. Mounting: TheIND-HVAC-DTW-UVC-R2-SS-36-3L-220V is designed to be mounted inside an air duct. The system is intended to be mounted in a partial internal style with the bulb(s) being mounted inside of the air duct and the electronics mounted on the outside of the duct. Note on Environment: Sunlight and visible light fixtures do not impact the effectiveness of the disinfecting on this UVC sanitation product. Metal halide, high pressure sodium, fluorescent, and LED light fixtures can be left on. The UV radiation emitted from this product is not disrupted by any type of lighting in the environment. Put simply, NO it DOES NOT need to be dark in the area you plan to disinfect. The UV radiation is harmful to the eyes and skin, and that is why you should not be in the area while it is in operation. Please see user manual for additional safety information. Applications: This ultraviolet UV air duct disinfection system can be used to continuously disinfect air of mold, allergens, airborne bacteria, viruses, and germs. TheIND-HVAC-DTW-UVC-R2-SS-36-3L-220V is ideal for use in restaurants, hospitals, clinics, laboratories, nursing homes, schools, food processing facilities, office buildings, conference rooms, universities, clean rooms, and many more. Larson Electronics is a manufacturer and as such can build stationary and portable transformer systems to your specifications. Although we carry several models of power distribution transformer systems, we can deliver custom ordered units almost as quickly as our prebuilt units. If this model does not meet your needs, please contact us at 1-800-369-6671 or to discuss your specific requirements.

Shipping and delivery Information

The PuriLite Peace of Mind 30-day money back guarantee

Payment

American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Vos informations de paiement sont gérées de manière sécurisée. Nous ne stockons ni ne pouvons récupérer votre numéro de carte bancaire.

You may also like

Recently viewed