Portable Industrial UV Sanitation Light - Kills 99% of Viruses - 500 sq.ft. Area - (4) UVC Lamps - Digital Timer - 25' SOOW Cord

LARSON ELECTRONICSSKU: PL3-IND-UC.360-24-4L-UVC-AT-25C
filler

Prix:
Prix réduit$10,966.00

Description

Specifications / Additional Information
This unit is Made In USA - Manufactured in Texas
IND-UC.360-24-4L-UVC-AT-25C Portable UV Sanitation Light Ratings/Features
Lamp Technology: UV-C Fluorescent NRTL Listed to UL 508A
Lamp Qty: (4) NRTL Listed to CSA C22.2 No. 14
Dimensions: 19"-L x 19"-D x 36"-H Short-wave Germicidal Light
Weight: 40 lb Kills 99% of Viruses and Other Germs
Voltage: 120 V AC, 50/60 Hz Made in USA - Manufactured in Texas
Total Watts: 80W EPA Reg. No 98409-1
Single-lamp Watts: 20W EPA Est. No. 98409-TX-1
Total UV Output: 36.4W
Single-lamp UV Output: 9.1W
Effective UV Radiation (at 1 Meter) Per Lamp: 75.0 uW/cm2 @ 1M
Total Effective UV Radiation (at 1 Meter): 300.0 uW/cm2 @ 1M
Coverage: 500 sq. ft.
Expected Lifespan: 8,000+ Hours
UV Wavelength: UV-C, 200nm - 280nm (254 nm)
Lamp Type: T8
Lamp Base: G13 (Medium Bi-Pin)
Replacement Lamp: FRL-24-1X-T8-20W-UV-C
Beam Angle: 360°
Light Configuration: Flood
Setting: Digital Timer
Delay: 1 Minute and 30 Seconds
Safety Kit: (2) Warning Signs, (1) Safety Glasses
Amps: -
Ambient Operating Temp Range: - Special Orders - Requirements
Materials: -
Lamp Protection: Wire Guard and Center Rail
Mounting: Portable - (4) Wheels
Wiring: 25' 16/3 SOOW Cord w/ Cord Cap
Cord Cap: 5-15 Straight, L5-15 Twist, or Pigtail
***PLEASE NOTE: UV-C light can cause temporary or permanent loss of vision, and temporary acute redness or ulceration (mild to severe sunburn) to exposed skin. To prevent exposure, do not operate the device in any application that allows UV-C light to be visible during operation. NEVER LOOK DIRECTLY AT THE BULB OR DISINFECTING TARGET ZONE. DO NOT touch bulb with bare hands. The oils in your skin will damage the lamp. Fingerprints will result in reduced performance and significantly reduce the lifespan of the lamp unless they are removed with alcohol. Please read instruction manual for UV safety requirements before operating.***
' Product Overview '
function MM_openBrWindow(theURL,winName,features) { //v2.0 window.open(theURL,winName,features); }
This unit is Made In USA - Manufactured in Texas The Larson Electronics IND-UC.360-24-4L-UVC-AT-25C is an Industrial UV Portable Sanitation Light which can disinfect 99% of viruses, bacteria, mold, and spores in large facilities. This unit offers UV-C output at a range of 200nm - 280nm (254nm) and comes equipped with four UVC fluorescent lamps. Four caster wheels on the bottom of the light allow for easy movement and positioning around the operating area. *Please note: This product produces UV light. Make sure to follow all safety guidelines and protocols found in the user manual. UVC light in the proper setting kills up to 99.9% of viruses, mold, spores, and bacteria. * The IND-UC.360-24-4L-UVC-AT-25C is a powerful sanitation solution for industrial sites and commercial facilities. Equipped with four UVC fluorescent lamps, this system offers 36.4 watts of total UV output, within the 200nm - 280nm UV-C range (254 nm). The lights have an expected lifespan of 8,000+ hours and emit a flood beam pattern. This UV system caters to 500 square feet of space with 360 degrees of coverage. Operators may move the light around after exposure time to disinfect several sections. With a recommended 20-25 minute exposure time for viruses, multiple units can be purchased to cover larger areas quicker. The UV light kills 99% of viruses, bacteria, mold, and spores. At start up, there is a built-in 1-minute and 30-second delay to allow individuals to safely leave the room after deploying the device. An accessible digital timer enables operators to set exposure times. The lights will automatically turn off when the set time is complete. Operators may adjust settings via a controller at the bottom of the unit. Two warning signs and a pair of safety glasses are included with the device.
Distance from Cart** Irradiance/Second Exposure Time Required* Coverage Area***
6 inch 10836.00 uW/cm2 1.27 seconds 2.5 ft x 2.5 ft
12 inch 5443.20 uW/cm2 2.54 seconds 3.5 ft x 3.5 ft
18 inch 3024.00 uW/cm2 4.56 seconds 4.5 ft x 4.5 ft
2 foot 1957.20 uW/cm2 7.05 seconds 5.5 ft x 5.5 ft
3 foot 1024.80 uW/cm2 13.47 seconds 7.5 ft x 7.5 ft
4 foot 516.60 uW/cm2 26.71 seconds 9.5 ft x 9.5 ft
5 foot 330.62 uW/cm2 41.74 seconds 11.5 ft x 11.5 ft
6 foot 229.60 uW/cm2 1 minutes 13.5 ft x 13.5 ft
7 foot 168.69 uW/cm2 1.36 minutes 15.5 ft x 15.5 ft
8 foot 129.15 uW/cm2 1.78 minutes 17.5 ft x 17.5 ft
9 foot 102.04 uW/cm2 2.25 minutes 19.5 ft x 19.5 ft
10 foot 82.66 uW/cm2 2.78 minutes 21.5 ft x 21.5 ft
12 foot 57.40 uW/cm2 4.01 minutes 25.5 ft x 25.5 ft
15 foot 36.74 uW/cm2 6.26 minutes 31.5 ft x 31.5 ft
18 foot 25.51 uW/cm2 9.02 minutes 37.5 ft x 37.5 ft
20 foot 20.66 uW/cm2 11.13 minutes 41.5 ft x 41.5 ft
22.5 foot 16.33 uW/cm2 14.09 minutes 46.5 ft x 46.5 ft
25 foot 13.22 uW/cm2 17.39 minutes 51.5 ft x 51.5 ft
28 foot 10.54 uW/cm2 21.82 minutes 57.5 ft x 57.5 ft
30 foot 9.18 uW/cm2 25.04 minutes 61.5 ft x 61.5 ft
32.5 foot 7.83 uW/cm2 29.39 minutes 66.5 ft x 66.5 ft
35 foot 6.75 uW/cm2 34.09 minutes 71.5 ft x 71.5 ft
40 foot 5.17 uW/cm2 44.52 minutes 81.5 ft x 81.5 ft
45 foot 4.08 uW/cm2 56.35 minutes 91.5 ft x 91.5 ft
50 foot 3.31 uW/cm2 69.57 minutes 101.5 ft x 101.5 ft
*Exposure time is based off of total irradiance. The above calculations are based on 12mJ total exposure. This level of exposure deactivates most organisms. **Distance from cart is surface distance from each side. ***Coverage area is calculated based on the cart being in the center of this area. This coverage area factors in the size of the cart. Please see "Distance from Cart" column for distance from one side of the cart.
Voltage: The IND-UC.360-24-4L-UVC-AT-25C operates on 120 V AC.
Click Photos to Enlarge
5-15 Straight Blade Plug 15 Amp / 125V Rated L5-15 Twist Lock Plug 15 Amp / 125V Rated Flying Leads / Pigtail Wires
Wiring/Plug: This unit is equipped with 25 feet of 16/3 chemical and abrasion resistant SOOW cord that is fitted with an industrial grade cord cap for easy connection to common wall outlets. Plug options include standard 5-15 15 amp straight blade plug for 110V wall outlets with ground or NEMA L5-15 15 amp twist lock plug for 125V twist lock outlets. Alternatively, we can provide flying leads with no plug for hard wire applications or for operators who prefer to wire in user provided cord caps. Please choose pigtail option below for flying leads with no plug. Cart: Operators can easily move the UV lighting system around facilities via four wheels at the bottom. A center rail enables seamless guidance and positioning of the unit. For best results, the light should be setup in the middle of the area. Note on Environment: Sunlight and visible light fixtures do not impact the effectiveness of the disinfecting on this UVC sanitation product. Metal halide, high pressure sodium, fluorescent, and LED light fixtures can be left on. The UV radiation emitted from this product is not disrupted by any type of lighting in the environment. Put simply, NO it DOES NOT need to be dark in the area you plan to disinfect. The UV radiation is harmful to the eyes and skin, and that is why you should not be in the area while it is in operation. Please see user manual for additional safety information. Suggested Applications: Sanitation, disinfection, retail spaces, lobbies, commercial locations, industrial parks, schools, public transportation hubs, airports, office buildings, medical centers, and more; kills 99% of viruses, bacteria, mold, and spores.

Shipping and delivery Information

The PuriLite Peace of Mind 30-day money back guarantee

Payment

American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Vos informations de paiement sont gérées de manière sécurisée. Nous ne stockons ni ne pouvons récupérer votre numéro de carte bancaire.

You may also like