58' Pneumatic Megatower™ on 21 Foot Trailer - (6) 1000 Watt Metal Halide Lights – 10KVA Genset

LARSON ELECTRONICSSKU: PL3-WCDE-11-PLM50-6X1000W-MH
filler

Prix:
Prix réduit$311,970.00

Description

Specifications / Additional Information
WCDE-11-PLM50-6X1000W-MH Trailer Mounted Metal Halide Megatowerâ„¢ Quick Summary
Genset Specs: 10KVA Kubota Brushless Genset
Genset: Kubota GL11000TM 110 Gallon External Fuel Cell
Engine: Kubota D722 16.3 HP Cold Weather Package Factory Installed
Engine Type: Vertical, liquid-cooled, 4-cycle diesel engine Up to 43 Hour Continuous Operation
Engine Speed: 3600 RPM Class F Rotor Coil, Class B Stator Coil
No. of Cylinders: 3 13.5` to 58` Light Mast
Generator: 11KW 2-Pole Brushless Pneumatic Aluminum Mast
Voltage: 120/240V Single Phase Steel Construction Trailer
Battery 12V @ 36aH Electric Air Powered Mast Operation
Grounding: Grounding Rod to Trailer Frame 1/3 HP Electric Air Compressor
Receptacles: L6-20R 20A 240V RCD Protected High Output Metal Halide Lamps
Receptacle Protection: RCD Circuit Breaker Extreme Area Coverage
Fuel Cell Capacity: 110 Gallons - External Tank w/ Anti-Splash Baffles NEMA 4 Panel
Fuel Delivery: Electric 660,000 Total Lumen Output
Sound Level: 65 dB - Full load @ 23` away Independently Adjustable Light Heads
Insulation: Class F (Rotor Coil), Class B (Stator Coil Dial-in Adjustability per light head
Cold Weather Package: Yes -Factory Included 98% Transmission High Purity PMMA Optics
Switched Breaker System per Lamp Head
Light Mast Specs IP55 Metal Halide Fixtures
Tower Length: 13.5` to 58` All Equipment Mounted on a 21` x 8` Trailer
Lamp Qty: (6) Steel Trailer w/ Industrial Grade Paint Finish
Materials: Heat Treated 6063B/T5 Aluminum Powered Boom Deployment
Finish: Powder Coated Towable Height Under 13` w/ Light Heads
Operation: Pneumatic w/ Hydraulic Ram 6-Point Outrigger System
10,000 lb Leveling Jacks
Light Head Specs E40 Lamp Base
Lamp Type: Metal Halide Picking Eyes for Crane Transport
Total Wattage: 6,000W (1000W per lamp)
Total Lumens: 660,000 (110,000 per lamp)
Voltage: Universal - 100-277V AC
Lighting Configuration: Flood Beam Pattern
Trailer Specs
Materials: Steel
Trailer Dimensions: 21`-L x 8`-W trailer bed
Height (Mast Collapsed): 9` 7"-H
Height (Mast Extended): 56`-H
Footprint (Outriggers Extended): 28`-6" x 19`-11"
Hitch: 3" Lunnett
Wiring: 7-Pin Flat
Axles: 7,000 lbs w/ Electric Brakes
Suspension: 7,000 lbs Leaf Springs
Outriggers: (6) 6` x 6" x 6" I-Beams Retractable w/ (6) 10,000 lbs Manual Leveling Jacks
Wheels: (4) 16" 5x4.5" Steel Rims
Tires: (4) P235/80R16
Weight: 8,500 lbs
Shipping:  Common Freight
Shipping Dimensions: 27`L x 8`W x 6.5`H
Options: Length- Mounting-Fixtures/ Call Us for Special Requirements
3 year warranty replacement on this light mast. The customer ships the failed light mast to Larson Electronics at their expense. If the failure is a manufacturer defect, we will repair and/or replace the unit.
' Product Overview '
function MM_openBrWindow(theURL,winName,features) { //v2.0 window.open(theURL,winName,features);}
Made in the USA The Larson Electronics WCDE-11-PLM50-6X1000W-MH is a metal halide lighting Megatowerâ„¢ that offers high output illumination and fuel savings over traditional light plants. This trailer mounted fold over 7-stage pneumatic light plant provides a safe and effective way for operators to quickly deploy six metal halide light heads to elevations up to 58 feet. This pneumatic light tower folds over for easy transportation, features a hydraulic ram upright assist, air powered pneumatic mast and high output IP55 rated metal halide fixtures. The metal halide light tower is powered by a 10 KVA Kubota diesel generator with a 110 gallon fuel tank. The entire assembly is mounted onto a 21` by 8` tandem axle trailer, allowing operators to transport this fold over boom from location to location. *PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO LIGHT MASTS OR LIGHT TOWERS* The WCDE-11-PLM50-6X1000W-MH Metal Halide Megatowerâ„¢ is a self contained, towable, high power light tower package. This unit contains a water cooled diesel engine powering a 10 KVA Kubota generator, which supplies the current for six 1000 watt metal halide lights producing 110,000 lumens each, for a combined total of 660,000 lumens of light. This unit can run uninterrupted in temperatures ranging between -10 degrees Celsius and +55 degrees Celsius for up to 43 continuous hours without refueling and includes a pneumatic telescoping light mast which can elevate the six high output metal halide lamps to a height of 58`. The light tower uses a NEMA 4 panel, which houses the electronics of the unit. This mobile floodlight package is ideal for large scale event illumination, construction, mining, industrial operations, and anywhere a mobile full power lighting system capable of extended operation is needed. This telescoping seven stage pneumatic light mast from Larson Electronics is designed to allow operators to quickly and safely deploy up to 6,000 watts of high intensity metal halide lighting in locations where illumination must be elevated to heights up to 58` for effective coverage. This light boom can be extended to 58` for maximum area coverage, and collapsed to 22` for applications where a smaller footprint is required. The tower is constructed of heat treated aluminum tubing with 2.69` foot of overlap per section. The mast is elevated using an included hydraulic ram, and extended to its full height using a trailer mounted air compressor. A 90" wide by 109.5" tall and 2" by 2" by 1/4" thick steel mast head is attached to the upper section of the mast which provides a strong and stable platform for the six 1000 watt metal halide light heads.
Accessories: This light tower comes with a convenient 240V/20 amps outlet with RCD protection, one main RCD circuit breaker (10-30 mA) and a grounding rod. Lights: Included with this light tower is one of our wet area suitable high output metal halide fixtures, producing a combined total of approximately 660,000 lumens at 1000 watts. The light head contains six high output metal halide lamps, producing 110,000 lumens per fixture. Each floodlight is securely fastened to the light boom and each lamp includes a support bracket to help maintain lamp stability within its housing. The lamps are hard wired into a NEMA 4 panel located on the end of the telescoping boom. The 1000 watt metal halide light produces exceptional illumination using a 19” aluminum reflector housing that spreads a powerful flood pattern of high quality light over large areas. This fixture is equipped with a 1000 watt metal halide lamp which produces the intense illumination and exceptional color rendering normally associated with these lamps. The metal halide lamp is secured within a separate die cast housing for strength and durability while a clear tempered glass lens provides protection for the lamp. The unit is the light head only, no remote ballast included. This fixture is U.L. listed for wet area certification and the high power flood beam produced by this lamp makes it ideal for applications requiring illumination of large scale areas that may be subject to wet conditions.
Click Images to Enlarge
Telescoping Boom: The pneumatic telescoping boom is constructed of heat treated aluminum with an powder coated finish and extends up 58` in height. This boom is raised from and lowered to the folded position by a single hydraulic ram, and extended or retracted by pnumaitc system with equipped air compressor. Wiring/Controls: A NEMA 4 panel can be found on this unit, which is a job box used to house all electronics associated with the light tower. The air compressor and battery charger are powered from within this breaker box. Power is provided to the control box via an integraged 10KVA genset. The mast elevation is controlled by a push button switch to operate the hydraulic ram, allowing operators to raise the mast to the upright position. The vertical deployment is operated by an up/down level, allowing operators to extend it to its full 58` height or retract it to the collapsed height. Genset: The WCDE-11-PLM50-6X1000W-MH mobile Megatower™ includes a Kubota Lowboy II GL11000TM genset that houses a Kubota D722 diesel engine that powers the 10KVA 120/240V brushless generator. This genset is liquid cooled and features a single phase generator with electric start ignition. The diesel generator runs at 3600 RPM and is equipped with an EPA/CARB Tier 4 emissions system. A 110 gallon fuel cell sits beside the genset and is equipped with an electric fuel delivery system. The fuel cell is constructed of single a heavy gauge steel single wall frame with internal anti-splash baffles. This genset features key operated electric starting, a twelve volt electrical system, liquid cooling, replaceable dry element air cleaner, and a full enclosure for safe operation and protection against the elements. This engine also features cold weather options to improve performance under cold weather conditions.  
Click Images to enlarge.
The above images show a side by side comparison of the light output between our LED light plant and a traditional four lamp metal halide light plant. The left image shows the metal halide light plant raised to 30` and illuminating a 50,000 sq ft work area with four 1000 watt metal halide light fixtures. The right image shows the LM-SMWB-HLM65-20X500LTL-LED-SYNC light plant raised to 50`, illuminating the same 50,000 square foot work area with twenty 500 watt LED fixtures. Notice how the color and intensity of the work area is greatly improved when lit up by the LED fixtures.
Click Images to enlarge.
The left image above shows the light mast illuminating a 300,000+ square foot area. The yellow billboard in the image reaches 40 lux, while the fence at the tree line (500`+ away from the tower) reaches 35 lux. This image was taken from 50` behind the mast and at 100` above ground level. The image to the right shows the work space 75` in front of the mast, with the entire area work area reaching over 100 lux. The mast was extended to 35`. The left image above shows the same 300,000+ square foot area being illuminated. In the background you can see a vehicle with their headlights on, barely able to be seen in comparison to the LM-SMWB-HLM65-20X500LTL-LED-SYNC light plant. This image was taken at 80` to the right of the mast and 175` above ground level. The mast was extended to 35`. The image on the right is a Google Earth export of the physical area being illuminated, for scale purposes.
    Trailer: The entire unit is mounted onto a four wheel, tandem axle trailer constructed of 8" box steel. Each axle is rated at 7,000 lbs and equipped with P235/80R16 tubeless tires and wheels. The rear axle is equipped with electric brakes. Tongue weight is rated at 650 lbs and an adjustable 3” lunnett eye for pintle hitches provides secure hookup to tow vehicles. A single 7,000 lbs rated tongue jack provides a stable connect-disconnect platform as well as additional stability during tower deployment. Standard heavy duty safety chains are included. This trailer also includes a front mounted storage area for stowing tools and accessories. The trailer is finished in industrial grade paint for protection against rust and corrosion and provides an attractive finish. Overall dimensions of the entire trailer and boom assembly in the stowed for travel configuration is 21` long by 8’ wide. Picking eyes allow operators to crane/hoist the unit around job sites. Six 7,000 lbs hand crank jacks are used for raising the trailer up off the ground, and four 7,000 lbs hand crank jacks mounted on extending outriggers are used for leveling and stabilizing the trailer assembly. Each of the four jacks are attached to a pivoting outrigger constructed of 6` by 6" by 6.3" steel I-beams. The jacks can be leveled by hand crank or attachment provided for power drills. These outriggers can be extended 6` out from the side of the trailer for added stability. This light plant can withstand 35 mph winds when fully extended. When lowered to 30`, the mast can withstand 50 mph winds. When lowered to 22`, the mast can withstand wind speeds up to 95 mph with gusts of 125 mph. Custom builds can be provided for higher wind speed resistance when fully raised. Runtime: The six 1000 watt metal halide light heads are able to achieve up to 43 hours of continuous use on a single tank of gas when only operating the light heads and air compressor. When running 24 hours a day and 7 days a week, this meta halide light plant will run for nearly 2 days straight without refueling. When the genset is running for 12 hours a day, this tower will provide on-site illumination for up to 4 days before needing more fuel. We offer a choice of finishing, equipped light heads, and with or without gensets. These towers can be fitted with Larson Electronics line of high output light heads, or customize the mast head to meet the mounting requirements for your equipment. Optional diesel generators and fuel cells can be equipped from factory, or retrofitted after purchase. Cold Weather Package: The WCDE-11-PLM50-6X1000W-MH is designed to withstand extreme cold environments and harsh winters. The pneumatic system is equipped with a de-icing system to prevent the air compressor, air lines, and pneumatic mast from freezing from moisture building within the air system. This de-icing system uses an environmentally friendly (non-toxic) fluid. All air lines are equipped with cold weather rated hydraulic hoses rated for -65°C and fitted with metallic hardware. The air compress consists of an oil-less unit equipped with an aluminum air regulator, stainless steel ball valves, and stainless steel valve controls. The head of the air compressor is wrapped with heat trace to prevent the compressor from freezing over in subzero temperatures. All the pneumatic controls are housed within an insulated and weather tight enclosure. This pneumatic control box features 1/2" thick polystyrene foam insulation and heat trace. The hydraulic system features -65°C cold weather rated rubber hydraulic hoses with metallic fittings and a cold weather rated high viscosity hydraulic fluid. The battery system that powers the hydraulic system features a cold weather rated sealed acid glass mat 12 volt battery wrapped in a heated battery blanket. A cold weather rated battery charger keeps the 12 volt battery charged. All battery components are enclosed within a NEMA 4 housing. All electrical components are wired using cold weather rated SOOW cable with rated to -50°C that features high flexibility, and extreme abrasion, acid, oil, and water resistance even in sub-zero climates. The Kubota genset is retrofitted with a coolant heater to keep engine temperatures at optimum levels. The fuel system is equipped with an in-tank fuel heater to prvent gelling in arctic environments. The genset is equipped with 0W-40 synthetic oil. The genset`s electric battery is equipped with a battery blanket.
Click Photos to Enlarge
Suggested Applications: Temporary lighting, construction sites, and security camera deployment. We can equip this mast with 1000W HID-22-SL-REM or 1500W HID-22-15M-SL-REM Metal Halide lights or a wide variety of high powered LED lights with comparable power, including the , , , , and .
 

Shipping and delivery Information

The PuriLite Peace of Mind 30-day money back guarantee

Payment

American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Vos informations de paiement sont gérées de manière sécurisée. Nous ne stockons ni ne pouvons récupérer votre numéro de carte bancaire.

You may also like

Recently viewed