Indoor Intrinsically Safe Telephone and Exp Proof Isolation Barrier – C1/2/3,D1/2 - 120V/240V
Indoor Intrinsically Safe Telephone and Exp Proof Isolation Barrier – C1/2/3,D1/2 - 120V/240V
Sold by: LARSON ELECTRONICS
| Indoor Intrinsically Safe Telephone and Exp Proof Isolation Barrier €“ CI,II,III,D1/2 - 120V/240V Options | Quick Summary |
| Intrinsically Safe Telephone Specs | Intrinsically Safe Telephone Summary |
| Device Type: Telephone (Indoor) | Class I, Division 1, Groups A, B, C and D |
| Dimensions: 8€ x 9.5€ x 3.8€ | Class II, Groups, E, F and G (Including Coal Dust) |
| Weight: 6 lbs | Class III, Division 2, Groups A, B, C and D |
| Operational Voltage: 110VAC/220VAC | ISO 9001 Certified |
| Operating Temp Range: -40°C to +60°C | cUL/UL Listed |
| Keypad: Braille Metallic | Hearing Aid Compatible (HAC) |
| Ringer: Shrill-Type Penetrating Ringer | NEMA Type 12 |
| Microphone: Dynamic Noise-Cancelling | |
| Signaling: DTMF only | Explosion Proof Isolation Barrier Summary |
| Class I, Groups A, B, C, D (Approved) | |
| Explosion Proof Isolation Barrier Specs | Class II, Groups E, F, G (Approved) |
| Device Type: Isolation Barrier Unit (Non-classified) | Class III (Approved) |
| Telephone Network Interface: BELL Pub.61100 Compatible (2-Wire) and 4-Wire Options | Type 3R (Rainproof) |
| AC Power Input: 90-132V or 180-240V | Resistant to Chemicals |
| Frequency: 47-63 Hz | |
| Current: 0.5 Amps | |
| ISI Voltage: 8V (Maximum) | |
| ISI Resistance: 66 Ohms (Maximum) | |
| ISI Current Limited: 136 mA (Maximum) | |
| Ringer Pitch Adjust: 1 kHz - 8 kHz (Nominal) | |
| Indicators: IS Loop Current (IS LOOP, GRN), IS Lock Detect (IS LOCK, GRN), Telephone Line Loop Current (TELCO, YEL), Hook (HOOK, YEL) | |
| Wiring Construction: Twisted Pair | |
| Wiring Type: Shielded | |
| Wiring Conductor Size: 24 AWG | |
| Wiring Loop Resistance: 275 Ohms | |
| Wiring Capacitance: 0.316 uF | |
| Operating Temp Range: -40°C to +60°C | |
| Relative Humidity: 95% (Non-Condensing) | |
| Dimensions: 13.16€ x 9.39€ x 7.46€ | Toll Free: 1-800-369-6671 |
| Body Material: Glass-Reinforced Polyester | Intl:Â 1-214-616-6180 |
| Mounting Holes: 4 (0.280-inch Diameter) | |
| Weight: 8.5 Lbs |
| Made in the USA The Larson Electronics indoor intrinsically safe telephone with isolation barrier is designed for use in hazardous work areas, such as chemical plants, oil refineries and settings where combustible gases or dust may be present. Both components may be used together to form an explosion proof telephone system under Class I, II, III, Division 1 and 2 hazardous locations. The indoor telephone is configurable with master/slave systems and rack barrier/isolation barrier configurations. Both system components are 120V/240V compatible (voltage selection at the bottom of the page). Intrinsically Safe Telephone Features: This intrinsically safe telephone supports a switchable 110VAC/220VAC power supply and 12V nominal voltage. It can operate in temperatures ranging between -40°C and +60°C, making it suitable for subzero environments. The housing is NEMA Type 12 and is constructed of anti-corrosive, polyester material. This allows the unit to resist thermal degradation, while providing protection against chemicals, solvents and salts. The unit is fully sealed with concealed mounting accessories. Weighing just six pounds, the explosion proof communication device supports the following dimensions: 8€ x 9.5€ x 3.8€Â. The €œG€ style handset features a noise-cancelling microphone, as well as robust volume control. A six-foot cord that is made out of Hytrel can be found on the device for extended usage. The keypad is chrome plated and supports Braille functionality. With a REN 0.4B, €œshrill-type€ penetration ringer, this unit is suitable for moderately loud work environments. This intrinsically safe telephone is registered under FCC Regulations, IC Certified and cUL/UL Listed for use in hazardous installations. Isolation Barrier Features: The Isolation Barrier supports 90-132V and 180-240V @ 47-63 Hz AC power input options. While the Intrinsically Safe Interface (ISI) features a maximum voltage of eight volts, 66 ohms resistance and 136 mA current limited. The unit is compatible with 2-wire (BELL Pub.61100) and 4-wire telephone network interfaces. This component is to be installed in a non-hazardous area of the location up to one mile from the explosion proof communication device. The Isolation Barrier interior comes with a power switch selector, a ring pitch adjustment, and four troubleshooting LEDs. Externally, the component consists of two modular subassemblies, the front panel and the rear enclosure assembly, for easy installation and wiring. Operators may adjust the pitch of the ring between 1 kHz and 8 kHz. This device operates in temperatures ranging between -40°C and 60°C with 95 percent (non-condensing) relative humidity. The Isolation Barrier supports a glass-reinforced polyester body, which is Type 3R rated, making it highly resistant to rain, weather and chemicals. There are four indicators on the unit that notifies operators about a wiring short in the IS phone and if the TELCO line has an open. In the event of an intermittent wiring short in the IS phone, the notification lights will flash. The Isolation Barrier features twisted pair (shielded) wiring with a wiring conductor size of 24 AWG. This component€™s wiring loop resistance is 275 ohms with a wiring capacitance of 0.316 uF. System Configuration: In an individual system configuration, the indoor phone is installed in the hazardous work area, with a cable connection to the isolation barrier unit in the non-hazardous area. For large communication system configurations or in settings where space is limited, a rack barrier may be used. Please note that the rack barrier and additional outdoor phone units that may be required for a fully functioning communication system do not come with this indoor telephone/isolation barrier system. If configured as a master/slave system, the master unit controls the speaking and listening function of the slave units. When the master unit€™s talk mode is being used, the slave units are automatically in listening mode. When the master unit is not being used in talk mode, the slave units will automatically default to talk mode which allows the master to receive audio while allowing hands-free operation for the slave units. Isolation Barrier Installation: The unit must be wired in accordance with Pub. 42004-380, Control Drawing 73242, to ensure intrinsic safety. Telephone system wire must be connected to the Isolation Barrier Unit only and not directly to the IS communication device. Shielded cables must be used when multiple IS telephone wires are routed together to prevent cross-talk. The shield must be grounded to an IS ground and connected only at the Isolation Barrier. There are four mounting holes (0.280-inch diameter) on this unit. |
Shipping and delivery Information
Shipping and delivery Information
Estimated delivery times range from same day to 2 weeks, depending on your location, the product ordered and stock availability. External factors such as courier network disruptions can also impact delivery timelines. PuriLite strives to ship your purchase in the shortest possible time using industry standard courier services.
For any questions related to shipping and delivery, please call +1-647-254-9757, email us at info@purilite.ca or chat with us by clicking on the chat icon at the bottom right of this page.
The PuriLite Peace of Mind 30-day money back guarantee
The PuriLite Peace of Mind 30-day money back guarantee
Enjoy our peace of mind 30-day money back guarantee on all products. If you are not satisfied with any of our products, your item is eligible for return within 30 days of purchase, subject to the terms & conditions below.
1. Goods must be returned in new & unused conditions with all original packaging. Do not write or put stickers on original packaging.
2. Any shipping charges incurred by Purilite to ship the product to your destination and returns from your location to our warehouse, in case of refused shipments, are non-refundable.
3. Depending on the product purchased, the client will be responsible for shipping product back to our warehouses.
4. Restocking fees map apply once inspected at our warehouse. All credits are subject to final inspection of good upon arrival at our destination.
5. Defective products are eligible for return.
If you purchased a product and did not receive the parcel, please contact us at sales@purilite.ca and we would be happy to assist you right away! PuriLite uses secure and well-established carriers (such as Canada Post, FedEx, Purolator, UPS etc.) to ensure your purchase is delivered successfully to your doorstep. All items are delivered with a tracking ID and are traceable. If your parcel was indeed not received, we will issue back a 100% refund.
Shop with confidence knowing that your purchase is protected, and your peace of mind is our commitment. Thank you for choosing PuriLite!
Sustainability & Ethical Sourcing
Sustainability & Ethical Sourcing
At PuriLite, we believe innovation should go hand-in-hand with responsibility. That’s why we’re committed to creating products that not only perform well but are also thoughtfully made with the planet and people in mind.
♻️ Sustainable Practices
- We prioritize durable materials that extend the product life cycle and reduce waste.
- Where possible, our packaging is made from recyclable or minimal-waste materials, helping to reduce environmental impact.
- Many of our electronic products are designed with energy efficiency in mind to minimize power consumption.
🤝 Ethical Sourcing
- We partner with manufacturers who fillow fair labor practices, ensuring safe working conditions and fair wages for their workers.
- All suppliers are carefully vetted for compliance with environmental and ethical standards.
- We avoid the use of materials from conflict zones and work to reduce the environmental footprint across our supply chain.
🌍 Our Ongoing Commitment
We're actively exploring new ways to improve—from using eco-certified components to optimizing our logistics for a lower carbon footprint. Every small step counts, and we’re committed to doing our part in building a more sustainable future.