Explosion Proof Exit Sign - C1D1/2 - 120V 50/60Hz - 4" Letters, English/Spanish - Battery Backup - I

LARSON ELECTRONICSSKU: PL3-EXP-EMG-EXT-LE6-1L-SLD-120V
filler

Price:
Sale price$3,115.99

Description

Specifications / Additional Information
EXP-EMG-EXT-LE6-1L-SLD-120V Explosion Proof Exit Sign Ratings/Approvals
Listing: United States & Canada Listed for United States & Canada
Lamp Type: LED Class I, Divisions 1 & 2, Groups B, C, D
Dimensions: 25€H x 13€W x 10.5€D Class I, Zones 1 & 2, Groups IIB+H2, IIA
Voltage: 120 V AC, 50/60 Hz Class II, Divisions 1 & 2, Groups E, F, G
Watts: 1.1 Class III, Divisions 1 & 2
Lighting Configuration: Back Illuminated Sign Panel NEMA 3R, 4, 7 (B, C, D), 9 (E, F, G)
Battery Backup Runtime: 3 Hours NRTL Listed to UL 508A
Battery Backup: Nickel Cadmium Battery Pack NRTL Listed to UL 1203
Sign Lettering: EXIT/SALIDA NRTL Listed to CSA C22.2 No 14, 25, 30
Sign Color: Red or Green 3 Hour Emergency Runtime
Ambient Temp Range: 0°C to +60°C Self-Testing Unit
Ambient Humidity: 0-100% English/Spanish Lettering
Weatherproof Rating: IP65  
Materials: Copper Free Aluminum Housing
Mounting: Ceiling Mount, Pendant Mount, Wall Mount
Wiring: 3/4" NPT Wiring Hub Toll Free: 1-800-369-6671
Intl: 1-214-616-6180
' Product Overview '
The EXP-EMG-EXT-LE6-1L-SLD-120V from Larson Electronics is an Explosion Proof LED Exit Sign with Emergency Battery Backup that is Class I, Divisions 1 & 2, Groups B, C, D, Class I, Zones 1 & 2, Groups IIB+H2, IIA, Class II, Divisions 1 & 2, Groups E, F, G and Class III Divisions 1 & 2 rated for hazardous areas. Equipped with a 1.1 watt LED lamp, a 3 hour runtime and self diagnostic system, this failsafe exit sign helps show workers within hazardous environments where the exit is during power failures. This single-sided, English/Spanish exit sign features letters 4" in size and is an ideal emergency exit marking solution for hazardous locations where failsafe reliability is a must. The EXP-EMG-EXT-LE6-1L-SLD-120V is an effective option for operators who wish to ensure their hazardous workspaces employ the most up to date and reliable means of marking emergency exit-ways available. Under normal conditions this emergency exit lamp uses normal external power to illuminate its 1 watt LED array. In the case of power outages or in any situation where power is interrupted, this unit automatically switches to a battery backup which will power the unit for three hours or until power is restored. This fixture has three mounting options. The English/Spanish explosion proof exit sign reads: EXIT/SALIDA. Light Features: The EXP-EMG-EXT-LE6-1L-SLD-120V features a backlit LED array that each contain eight LEDs, drawing a total of 1.1 watts. This explosion proof emergency LED fixture features brown-out, short circuit and voltage surge protection and has a low voltage disconnect which prevents damage to the battery caused by a deep discharge. This self-testing LED fixture will run for a minimum of 3 hours after a power failure thanks to the maintenance-free 3.6 volt NiCad battery. After emergency use, the battery takes 24 hours to completely recharge.
Click Photo to Enlarge
This emergency exit marking fixture is explosion proof and carries an integral battery backup power supply. When external power is cut due to outages or accidents this lamp automatically switches to its battery backup which will power the lamp for three hours, longer than the requirements specified in the NFPA 101. The EXP-EMG-EXT-LE6-1L-SLD-120V sign panel is back illuminated by LEDs and as a result draws only 1.1 watt of power and has an extreme LED luminary lifespan rated at 15 years. This fixture is approved for outdoor use and is resistant to saltwater making it suitable for use in marine environments. Emergency Operation: The EXP-EMG-EXT-LE6-1L-SLD-120V features a backup battery that will run the fixture for at least 90 minutes following a power outage or any other loss of power. The included emergency backup battery is a 3.6 volt NiCad rechargeable unit. These batteries are maintenance-free and have a life expectancy of 15 years while being able to operate in a wide variety of conditions including in temperatures ranging from 0°C to +60°C. This unit also features a low voltage disconnect. This means that if the fixture detects that the battery`s terminal voltage has fallen below a certain level, the low voltage circuit will disconnect the emergency lighting load until normal power is restored. This prevents the battery from experiencing a deep discharge and becoming damaged. Wiring: The EXP-EMG-EXT-LE6-1L-SLD-120V explosion proof emergency self-testing LED fixture is NOT a factory sealed fixture. Operators will bring their own wiring to a junction box and complete their connects. The operator will also provide their own seal off for this fixture. The EXP-EMG-EXT-LE6-1L-SLD-120V operates on 120 V AC at 60 Hz. Mounting: The EXP-EMG-EXT-LE6-1L-SLD-120V is designed to be surface mounted to flat surfaces such as walls. The unions connecting the upper lamps to the lower indicator light enclosure allow for both horizontal and vertical adjustment. This gives operators the ability to adjust the light to their specific mounting location for ideal light coverage during a power failure or power outage. Suggested Applications: The EXP-EMG-EXT-LE6-1L-SLD-120V is designed to for use within hazardous environments to mark the exit-ways of rooms and buildings.