6,000 Watt, Air Cooled Diesel Generator - 30' Telescoping Tower - 4, 1000W Metal Halide Lights

LARSON ELECTRONICSSKU: PL3-HAL-WCDE-4X1000
filler

Price:
Sale price$64,671.99

Description

Specifications / Additional Information
HAL-WCDE-4X1000 Trailer Mounted Metal Halide Tower w/ Genset Quick Summary
Genset Specs: 8 KW Kubota Brushless Genset
Genset: 8 kW 12 Gallon Fuel Cell
Engine: Kubota 15.4 HP Up to 15 Hour Continuous Operation
Engine Type: Vertical, Air-Cooled, 3-Cylinder Diesel Engine, Naturally Aspirated 12' to 30' Light Mast
Engine Speed: 1800 RPM Steel Mast
No. of Cylinders: 3 Manual Mast Operation
Generator: 8 kW Marathon Brushless Steel Construction Trailer
Generator Amps: 49.95 A @ 120 V, 24.97 A @ 240 V (2) Adjustable Outriggers w/ Swivel JAcks
Voltage: 120/240 V Single Phase High Output Metal Halide Lamps
Fuel Tank Capacity: 12 Gallons 440,000 Total Lumen Output
Sound Level: 68 dB - Full load @ 23' away Switched Breaker System per Lamp Head
Fuel Consumption (Gallons per Hour): 0.31 Gal/hr @ 25% Load, 0.49 Gal/hr @ 50% Load, 0.80 Gal/hr @ 100% Load All Equipment Mounted on a Trailer
Runtime: 15 Hours @ Full Load Steel Trailer w/ Industrial Grade Paint Finish
Coolant Capacity: 7 Quarts Towable Height Under 12' w/ Light Heads
Oil Capacity: 5.4 Quarts 6-Point Outrigger System
Genset Dimensions: 39.42"-L x 24.00"-W x 24.50"-H 7,000 lb Leveling Jacks
Genset Weight: 583 lb (635 lb including Oil & Coolant) 110 Lumens Per Watt Efficiency
Light Mast Specs
Tower Length: 12' to 30'
Lamp Qty: 4
Materials: Steel
Finish: Powder Coated - Gloss Blue
Operation: (2) 1,000 lb Manual Winches, Electric Optional
Light Head Specs Light Head Ratings
Lamp Type: Metal Halide Class I, Division 2 Groups A, B, C, D
Total Wattage: 4,000W (1000W per lamp) Class I Zone 2, Groups IIC, IIB, IIA
Total Lumens: 440,000 (110,000 per lamp) Class II Div. 2 Groups F & G
Lighting Configuration: Flood Beam Pattern Class III Div. 1 & 2
Lens: Glass NRTL Certified to UL Standard 844
Weight: 45 lb (Each Lamp) NRTL Certified to UL Standard 1598
Trailer Specs
Materials: Steel
Trailer Dimensions: 12'-L x 8'-W Trailer Bed
Hitch: Standard 2" Ball Coupling w/ (2) Standard Safety Chains
Wiring: 7-Pin Flat
Axles: (1) 3,500 lb
Outriggers: (2) Adjustable Outriggers w/ (2) 1,500 lb Swivel Jacks
Wheels: (2) 15" Wheels w/ Protected Fenders
Tires: (8) P235/80R16
Weight: Approximately 1850 lb
Shipping: Common Freight
Shipping Dimensions: 13'-L x 8'-W x 6'-H
' Product Overview '
function MM_openBrWindow(theURL,winName,features) { //v2.0 window.open(theURL,winName,features); }
The HAL-WCDE-4X1000 from Larson Electronics is a Mobile Light Tower that provides a towable lighting package powered by an air cooled diesel engine. The engine turns a generator which produces 6 kW and 120/240 V @ 60Hz. The four 1000 watt metal halide lamps included with this unit produce 440,000 lumens (110,000 per lamp) and will illuminate a 5-7 acre area continuously without refueling for up to 15 hours. The HAL-WCDE-4X1000 mobile light tower is a self contained towable light tower package that produces enough light to illuminate an area up to 7 acres in size. This unit contains an air cooled diesel engine powering a 8 kW generator, which supplies the current for four Class I Division 2 1,000 watt metal halide lights producing 110,000 lumens each, for a combined total of 440,000 lumens of light. This unit can run uninterrupted for up to 15 hours straight without refueling and includes a telescoping light mast which can elevate the four metal halide lamps to a height of 30 feet. This mobile floodlight package is ideal for emergency services, large scale event illumination, construction, mining, industrial operations and anywhere an extended operation capable mobile lighting solution is needed. The HAL-WCDE-4X1000 mobile light tower includes an air cooled, three cylinder diesel engine that produces 15.4 horsepower at 1800 RPM. This engine features key operated electric starting, a full twelve volt electrical system, automatic low oil pressure and high temperature safety shutoffs, dual fuel filters, and easy access oil and radiator drain ports to facilitate maintenance. The 12 gallon fuel tank is sized to allow the engine to operate for up to 15 hours continuously without refueling. The engine comes with a spark arrestor installed. Generator: The 8 kW, 6 kVA generator is a single bearing 4 pole design with Class F minimum insulation producing single phase 120/240 voltage @ 60hz. This hazardous location light tower includes an ignition spark arrestor and heat insulated muffler (fiberglass wrap). The generator uses a four wire hookup system with an external ground allowing for setting up both electrical and mechanical safe grounding systems. The system is equipped with two explosion proof EPO-20A Class I, Div. 1 & 2, 125 Volt AC plugs rated at 15 amps, and one explosion proof EPO-20A Class I, Div. 1 & 2 250 Volt plugs rated at 20 amps. Lights: The lighting system on this unit is comprised of four Class I Division 2 1,000 watt metal halide lamps producing 110,000 lumens of light each attached to the end of the telescoping light boom. These floodlights produce a wide flood light pattern capable of illuminating a minimum of 5 acres with a combined total of 440,000 lumens of light. Each floodlight is securely fastened to the light boom and each lamp includes a support bracket to help maintain lamp stability within its housing. The lamps are connected to the power source via a water tight male pin connector that attaches to a receptacle located on the end of the telescoping boom. These lamps are Class I, Division 2 groups A,B,C, and D. Controls: The operations system for this unit is a centrally located control panel located within the light tower enclosure. Four Class I Division 1 switches allow individual on/off control of the lights while an individual hour meter tracks unit operating time. Also included is a battery charging indicator and alternator failure gauges. Telescoping Boom: This light boom can be extended to 30' for maximum area coverage and collapsed to 12' for applications where a smaller footprint is required. The tower is constructed of square steel tubing with a lower section 12' in length and 4" by 4" by 1/8" thick, middle section 11' in length and 3" by 3" by 1/8" thick, and an upper section 10' and 2" by 2" by 1/8" thick. Each section has a 1' overlap. The mast is elevated using an included 1,000 lb hand winch with 3/16" cable and extended to its full height using a second 1,000 lb hand winch. This system is capable of withstanding 65 mph winds when extended to its full height and the stabilizing outriggers are deployed. The stabilizing outriggers are a three point design abilizing outriggers with one located under the trailer tongue and two on the rear sides of the unit. The two rear outriggers are adjustable and include 1500 lb, swivel jacks for leveling and stabilizing the tower. Housing: All of the operating components are housed with a protective compartment constructed of 14 gauge steel and designed to provide airflow for cooling. Side doors provide access to the interior while latches provide secure closing while the unit is in use. The design and construction of this enclosure along with the commercial grade muffler system helps this unit operate at a low 63 Db level @ 23 ft. Trailer: The entire unit is mounted onto a two wheel trailer with a 3,500 lb leaf spring axle and 15" wheels with protected fenders. A standard two inch ball coupling and two standard safety chains allow for easy hookup and towing. The entire unit can be loaded and unloaded onto trucks via forklift sleeves mounted to the outer section of the light mast. The entire light tower system generator weighs 1850 pounds with shipping dimensions measuring 13 feet long, 8 feet wide and 6 feet tall.