Hazardous Location LED Light - C1D2/C2D2 - Corrosion Resistant for Marine - Modbus TCP/IP Network

LARSON ELECTRONICSSKU: PL3-HALP-ANC-48-2L-LED
filler

Price:
Sale price$3,200.00

Description

Specifications / Additional Information
HALP-ANC-48-2L-LED Hazardous Area LED Offshore Light Ratings
UL Listing: United States - Canada Class I Division 2, Groups A, B, C, D
Dimensions: W-8.25" x L-52" x H-7" Class II, Division 2, Groups F, G
Weight: 8 Lbs UL 844
Total Watts: 56 watts (28 Watts Per Lamp) UL 1598A Marine Type (Salt water)
Total Lumens: 7,000 (3,500 Per Lamp) California Title 24 Compliant
Voltage: Universal 120-277VAC 50/60 Hz or 12-24V AC/DC T4A Temperature Rated
Lamp Life Expectancy: 50,000 Hours USCG Approved
Luminous Efficacy: 120 Lumens per Watt Password Protected Network Controls
Temp Range: -30°C to +85°C No Programming Required
Beam Angle: 150° Modbus TCP/IP Connectivity
Color Temp: 5600K or 4500K
Minimum Operating Temp: -30 C
Maximum Case Temp: 90 C  
Mounting: Flange Type Surface Mount or Pendant Mount  
Wiring Hub: 1/2" or 3/4" Threaded  
 
Network Controller Specs  
Dimensions: 1.41" x 3.88" x 3.1"  
Weight: 5 oz  
Network Type: 10/100 Base-T Ethernet Port  
Protocols: HTTP, XML, Modbus TCP/IP  
Power Supply: 9-28V DC  
Digital Input: (1) Optically Isolated 4-26V DC  
Current: 950uA @ 4V, 8.5mA @ 26V  
Relay Contacts: (1) SPDT - 240V AC/30V DC Max @ 12A  
Relay Modes: On/Off or Pulsed  
Pulse Timer Duration: 0.1 to 86,400 Seconds  
Input Functions: Monitor, Local Relay Control, Remote Relay Control
LED Indicators: (4) Digital Input Voltage Applied, Relay Coil Energized, Network Linked, Network Activity
Operating Temperature: -40°C to 57°C
Housing Material: Lexan 940 Polycarbonate Plastic Toll Free: 1-800-369-6671
Mount: Surface, Wall or DIN Rail Intl: 1-214-616-6180
Password Protection: Yes @ Setup (Base 64 Encoding, 10 Characters)
Connectors: 3-position Removable (Relay- C, NO, NC), 5-position Removable (Power/Input), 8-pin RJ-45 (Network)
' Product Overview '
Made in the USA The Larson Electronics HALP-ANC-48-2L-LED Hazardous Area LED Light Fixture is a U.S./Canada UL Listed connected lighting solution for Class 1 Division 2 Groups A, B, C and D environments. Modbus TCP/IP network capable, this hazardous location LED light has a T4 temperature rating and carries a United States Coast Guard approval, making it ideal for applications such as oil rigs, ships, offshore applications, petrochemical, manufacturing, chemical storage, and water treatment centers. Operators can setup remote access, controls and configurations using the Modbus TCP/IP network controller (via a standard web browser). This four foot long, two lamp connected LED fixture is ideal for operators seeking a top quality hazardous location light that will reduce operating costs, improve lighting quality and reduce downtime incurred from frequent servicing intervals. The HALP-ANC-48-2L-LED hazardous area LED light fixture is designed for use in wet areas and saltwater-marine environments where corrosion resistance is critical to equipment longevity and safety. This Class 1 Division 2 rated fixture is constructed of non-corrosive materials including a polyester housing reinforced with glass fiber, a poured in gasket for reliable sealing and an impact resistant acrylic diffuser. Eight corrosion resistant plastic latches secure the lamp cover to the housing and provide a firm lock against the poured in seal to prevent drips and water intrusion. Aevum Network Controlled Lighting Solution: The Aevum Network Controlled Lighting Solution from Larson Electronics enables connected and intelligent illumination using cutting-edge and existing networks. Using Modbus TCP/IP or DALI (for fixtures with dimming features), businesses can seamlessly control lights and sensors from remote locations, without traditional light switches. Web-based panels facilitate real-time monitoring of connected equipment and allows operators to switch units on/off, configure activation settings and more. Businesses may utilize their own systems and software with these controllers, ensuring robust flexibility and cost savings (no contracts). The Aevum Network Controlled Lighting Solution can improve productivity in the workplace by automating basic lighting controls and making lighting controls widely accessible in the facility, via local networks or the internet. Operators also have the option to monitor the status of fixtures from a remote location, which can improve maintenance and reduce downtimes. Controls: Controls for the explosion proof LED fixture is accessible using a web-based control panel. Compatible with HTTP, XML, or Modbus TCP/IP protocols, network configuration is accessible using web-based pages (no programming required). Operators can monitor or setup controls from a remote area using the internet or local IP network and any standard web browser. Functions and controls include: on/off, pulse and monitor. LED indicator lights on the device provide the real-time information about digital input voltage, relay coil, network status and network activity. Password protection for the setup page is available (10 characters maximum).
Click Photo to Enlarge
We now offer our second generation LED tube lamps with this fixture which have increased this hazardous location light’s performance. This two lamp HAZLOC LED linear fixture is lighter in weight and produces more light than hazardous location fluorescent fixtures. The four foot long LED tube design bulbs included with this unit are rated at 50,000 hours of service life, which is over twice as long as standard T8 bulbs. The HALP-ANC-48-2L-LED is UL 844 rated and Class 1 Division II, Groups A, B, C, D approved. This fixture also carries a UL 1598A outdoor marine rating and meets US Coast Guard specifications. This lamp offers the extreme durability, high efficiency and long lamp life of high power LEDs in a proven hazardous location fixture design, making it a reliable and affordable lighting solution for open areas where flammable chemicals and vapors may occasionally be present. We have eliminated the ballast box normally associated with fluorescent fixtures which reduces overall weight and creates a slimmer unit profile. There is no ballast in this unit and the included LED lamps have a 50,000+ hour service life, both of which result in extreme efficiency and greatly reduced maintenance costs. The solid state design of the LED lamps give this fixture superior resistance to damage from vibration, extremes in temperature and a lamp service life over twice that of standard fluorescent bulbs. Unlike the glass tube design of traditional fluorescent lamps, these LED T-Style lamps have no filaments or fragile housings to break during operation. Instead of using a combination of gases to produce light, light emitting diodes (LEDs) use semi-conductive materials that illuminate when electric current applied and emitting light. The LED assembly is mounted to the "tube" constructed from extruded aluminum, with a polycarbonate lens protecting the LEDs. With LED lights, there is no warm up time or cool down time before re-striking and provide instant illumination when powered on, adding to the reliability of LED technology. By nature, LED light sources run significantly cooler than fluorescent lamps, reducing the chance of accidental burns and increased temperatures due to heat emissions. This solid state design of light emitting diodes provides a more reliable, stable, durable, and energy efficient light source over traditional fluorescent lighting. The 28 watt LED lamps produce 30% more illumination than standard T8 bulbs while offering lower amp draw and increased reliability. Each lamp produces 3,500 lumens at 125 lumens per watt, for a combined 7,000 total lumen light output. A HAL-48-2L-T8 hazardous location fluorescent light, with a combined total of 64 watts, draws 0.54 amps at 120 volts AC. This LED version of the same light, with a total of 56 watts, draws only 0.47 amps at 120 volts AC. The HAL-48-2L-LED-G2 is universal voltage, not multi-tap, and operates on any voltage from 120V to 277V AC 50/60hz without any modifications. We also make a 12/24V AC/DC version for low voltage applications for AC or DC power. Network: The network controller is equipped with one optically-isolated digital input and one SPDT relay contact. Compatible with 9-28V DC, the unit features a 3-position removable relay (N, NO, NC), a 5-position removable power/inputs and an 8-pin RJ-45 port for network connections. Operators can mount the device on walls, surfaces or din rails for space-saving benefits.
Energy Consumption Comparison
T5HO T8 LED
Wattage 108 watts 64 watts 56 watts
Amp Draw @ 120V AC 0.90 amps 0.54 amps 0.47 amps
Amp Draw @ 220V AC 0.49 amps 0.29 amps 0.25 amps
Amp Draw @ 240V AC 0.45 amps 0.27 amps 0.23 amps
Amp Draw @ 277V AC 0.39 amps 0.24 amps 0.20 amps
Amp Draw @ 12V DC 9 amps 5.34 amps 4.67 amps
Amp Draw @ 24V DC 4.5 amps 2.67 amps 2.34 amps
Lamp Life Expectancy 20,000 hours 24,000 hours 50,000 hours
Color Temperature 5000K / 4100K 4100K 5600K
Operation cost per year (12hs/day @ 12c/kWh) $56.77 $33.64 $29.43
Mounting Options: Unless otherwise specified, our standard, most popular configuration is the flange mount shown enlarged below. We also offer a pendant mount for those needing to suspend the fixture away from the ceiling surface (i.e. suspend from pipe or conduit). Additional mounting configurations can be customized to meet the requirements on the application. Please contact us for special mounting configurations.
Surface Mount (Standard)
Standard Flange Brackets: Flange type stainless steel mounts attached at each end of the fixture enables it to be simply secured to any surface. The mounts provide some shock absorbency protection while enabling the user to simply mount the fixture with the through-hole taps that protrude on each side of the fixture. The mounting holes are 38.25” on center apart along the top of this hazardous location light. The mounting holes are 7.2” on center across the top of the light.
Pendant Mount (Optional)
Standard Suspension Mounting: Pendant mount fixtures hang from the ceiling and are suspended by rigid pipe. Each fixture is equipped with either two 1/2" or 3/4” NPT hubs, one on each end of the fixture. Operators bring rigid pipe down to the threaded mounting hubs. Wiring is fed down through the rigid pipe to one of the NPT hubs and tied in to the fixture’s lead wires, completing the electrical connection. The remaining pendant hub provides support for the opposite end of the fixture. Suggested Applications: The HALP-ANC-48-2L-LED is designed for Modbus TCP/IP lighting networks, remote lighting networks, marine, wet, damp locations where corrosion resistant fluorescent lights are required or are already present. This includes petrochemical facilities, lubrication pits, oil drilling rigs, crew quarters, solvent/cleaning areas, water treatment areas, processing plants and marine loading docks.

Shipping and delivery Information

The PuriLite Peace of Mind 30-day money back guarantee

Payment

American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

You may also like

Recently viewed