Class I, Div. II Fluorescent Fixture w/ Emergency Ballast - 2 Foot, 2 Bulb

LARSON ELECTRONICSSKU: PL3-HALP-EMG-24-2L
filler

Price:
Sale price$1,471.99

Description

Specifications / Additional Information
HALP-EMG-24-2L U.L. Ratings
UL Listing: United States - Canada Class I Division 2, Groups A, B, C and D
Lamp Type: Fluorescent Class II, Division 2, Groups F, G
Dimensions: W-8.25 " L-52" H-7" UL 1598A Marine Type
Weight: 8 Lbs UL 844
Voltage: Universal 120-277VAC 50/60 hz UL 924
Total Watts: 34 watts UL 8750
Total Lumens F17-T8 Bulbs: 2,650 IP66 Rated
Luminous Efficacy F17-T8 Bulbs: 92 Lm/W NEMA 4X
LED Lamp Life Expectancy: 100,000+ Hours CSA 22.2 No. 137-M81
Color Temp: 4100K cUL Listed for Canada
Beam Angle: 150° Meets USCG Specs
Ambient Operating Temp Range:-40°C to +65°C T4 Temperature Rating
Operating Temp Range: T4C rated Switch Leg for Powering Light On/Off
Mounting: Surface Standard - Pendant Optional
Wiring Hub: (2) 1/2" or 3/4`" threaded NPT hubs
Battery Backup: 90 minute runtime at 900 lumens
U.L Approval:    Toll Free: 1-800-369-6671
Intl: 1-214-616-6180
  Fax: 1-903-498-3364
  E-mail: 
' Product Overview '
Made in the USA The Larson Electronics HALP-EMG-24-2L Hazardous Area Fluorescent Light Fixture is U.S./Canada UL Listed Class 1 Division 2 Groups A, B, C and D - UL 1598A listed, has a T4C temperature rating and is specifically designed to handle the rigors of wet and corrosive marine environments. This fixture is equipped with an added battery backup providing 90 minutes of emergency runtime. The HALP-EMG-24-2L hazardous area fluorescent light fixture is designed for use in wet areas and saltwater-marine environments where corrosion resistance is critical to equipment longevity and safety. This Class 1 Division 2 rated fixture is constructed of non-corrosive materials including a polyester housing reinforced with glass fiber, a poured in gasket for reliable sealing and an impact resistant acrylic diffuser. Corrosion resistant plastic latches secure the lamp cover to the housing and provide a firm lock against the poured in seal to prevent drips and water intrusion. This fixture is UL 844 rated and Class 1 Division II, Groups A, B, C, D approved. The HALP-EMG-24-2L also carries a UL 1598A outdoor marine rating and meets US Coast Guard specifications. This fluorescent light works, mounts and is wired like our HALP-24-2L explosion proof fluorescent light fixtures. The main difference is that we add a battery backup unit that adds emergency light functionality to the fixture. This hazardous area emergency light will run the standard UL suggested 90 minutes after power is lost. The light recharges the battery once electrical power is restored. Standard configuration includes a single emergency ballast that will run a single lamp at 900 lumens for 90 minutes.
 Click Photo to Enlarge
NOTE ON LAMPS: This fixture comes equipped with F17-T8 lamps producing 1,325 lumens per bulb, a 4100 Kelvin color and a 20,000 hour rated service life. Surface Mounting: Flange type aluminum mounts attached at each end of the fixture enables it to be simply secured to any surface. The mounts provide some shock absorbency protection while enabling the user to simply mount the fixture with the through-hole taps that protrude on each side of the fixture. The mounting holes are 14.91" inches on center apart along the top of this hazardous location light. The mounting holes are 9.5" inches on center across the top of the light. Pendant Mounting: This light fixture can hang from the ceiling suspected by rigid pipe. Each fixture is equipped with either two 1/2" or 3/4" NPT hubs on either side of the  fixture. Operators will bring rigid pipe down to the threaded mounting ups. The wiring is fed down through the rigid pipe to one of the NPT hubs and tied to the fixture`s lead wires to complete the electrical connection. The remaining pendant hub provides support for the opposite end of the fixture. Suggested Applications: HALP-EMG-24-2L is designed for marine wet and damp locations, where corrosion resistant fluorescent lights are required. This includes petrochemical facilities, lubrication pits, oil drilling rigs, crew quarters, solvent/cleaning areas, water treatment areas, processing plants and marine loading docks.
Made in USA Quality Lamp Options
1. Each unit dialectically tested. 2. Fixture arrives assembled and lamped to reduce installation time and cost. Flange type stainless steel mounts attached at each end of the fixture enables it to be simply secured to any surface. 3. Fixture housing constructed of glass fiber reinforced polyester. 4. Relamping done via 6 stainless steel snap locking latches, which enable the operator to remove the door and access the lamps. 5. Lamp cover-diffuser constructed of high impact acrylic for corrosion resistance and lamp protection. 6. 1/2" or 3/4", threaded access hole for wiring conduit. F17-T8 – 1325 lumens per bulb (2560) lumens total), 24,000 hours life, 4100 Kelvin color

Shipping and delivery Information

Payment

American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

You may also like

Recently viewed