Class I, Div. II 110 Watt Fluorescent - Emergency Battery Backup - Corrosion Resistant (Saltwater)

LARSON ELECTRONICSSKU: PL3-HALP-EMG-24-2L-BX-55W-3HR
filler

Price:
Sale price$2,581.99

Description

Specifications / Additional Information
HALP-EMG-24-2L U.L. Ratings
UL Listing: United States - Canada Class I Division 2, Groups A, B, C and D
Lamp Type: Fluorescent Class II, Division 2, Groups F, G
Dimensions: W-8.25 " L-26" H-7" UL 844
Weight: 5 Lbs UL 924
Voltage: Universal 120-277VAC 50/60 hz UL 1598A Marine Type
Total Watts: 110 California Title 24 Compliant
Total Lumens T5-HO Bulbs: 5,600 cUL Listed for Canada
Luminous Efficacy T5-HO Bulbs:: 66.25 Lm/W Meets USCG Specs
LED Lamp Life Expectancy: 20,000+ Hours T4 Temperature Rating
Color Temp: 5500K Switch Leg for Powering Light On/Off
Beam Angle: 150°
Ambient Operating Temp Range:-40°C to +65°C
Operating Temp Range: T4A rated
Mounting: Surface Standard - Pendant Optional Toll Free: 1-800-369-6671
Wiring Hub: (2) 1/2" or 3/4" threaded NPT hubs Intl: 1-214-616-6180
Battery Backup: 3 hour runtime at 900 lumens Fax: 1-903-498-3364
U.L Approval:  
' Product Overview '
Made in the USA The Larson Electronics HALP-EMG-24-2L-BX-55W-3HR Hazardous Area Fluorescent Emergency Light Fixture is U.S / Canada U.L approved Class 1 Division 2 Groups A, B, C and D - UL 1598A listed, has a T4A temperature rating and is specifically designed to handle the rigors of wet and corrosive marine environments. This fixture features two 5 watt compact fluorescent fixtures that produce 2800 watts each. The HALP-EMG-24-2L-BX-55W-3HR hazardous area fluorescent emergency light fixture builds on the effectiveness of our HALP-24 series by including bi-axial lamps which raise the fixture`s wattage and light output totals without increasing the unit`s size or weight. Although some efficiency is sacrificed for increased output, this unit`s lower cost and increased ouput helps offset this lower efficiency. This Class 1 Division 2 rated fixture is constructed of non-corrosive materials including a polyester housing reinforced with glass fiber, a poured in gasket for reliable sealing and an impact resistant acrylic diffuser. Corrosion resistant plastic steel latches secure the lamp cover to the housing and provide a firm lock against the poured in seal to prevent drips and water intrusion. This fixture is UL 844 rated and Class 1 Division II, Groups A, B, C, D approved. The HALP-EMG-24-2L-BX-55W-3HR also carries a UL 1598A outdoor marine rating and meets US Coast Guard specifications. This fixture ideal for hazardous areas where corrosion resistance is mandatory and space limitations require a powerful yet compact lighting solution. This fluorescent light works, mounts and is wired like our HALP-24-2L-BX explosion proof fluorescent light fixtures. The main difference is that we add a battery backup unit that adds emergency light functionality to the fixture. This hazardous area emergency light will run for 3 hours after power is lost. The light recharges the battery once electrical power is restored. Standard configuration includes a single emergency ballast that will run a single lamp at 900 lumens for 3 hours. The battery backup unit includes a switched leg for turning the light fixture on/off without kicking the unit into emergency mode.
 Click Photo to Enlarge
NOTE ON LAMPS: This fixture comes equipped with Bi-Axial Bulbs which increases the wattage of the standard HALP-EMG-24-2L from 34 watts with 2 standard T5-HO lamps to 80 watts with bi-axial bulbs. The HALP-EMG-24-2L-BX-55W-3HR has an electronic universal ballast and works on 120-277VAC. Surface Mounting: Flange type aluminum mounts attached at each end of the fixture enables it to be simply secured to any surface. The mounts provide some shock absorbency protection while enabling the user to simply mount the fixture with the through-hole taps that protrude on each side of the fixture. The mounting holes are 14.91" inches on center apart along the top of this hazardous location light. The mounting holes are 9.5" inches on center across the top of the light. Pendant Mounting: This light fixture can hang from the ceiling suspected by rigid pipe. Each fixture is equipped with either two 1/2" or 3/4" NPT hubs on either side of the  fixture. Operators will bring rigid pipe down to the threaded mounting ups. The wiring is fed down through the rigid pipe to one of the NPT hubs and tied to the fixture`s lead wires to complete the electrical connection. The remaining pendant hub provides support for the opposite end of the fixture. Suggested Applications: The HALP-EMG-24-2L-BX-55W-3HR is designed for marine wet and damp locations, where corrosion resistant fluorescent lights are required. This includes petrochemical facilities, lubrication pits, oil drilling rigs, crew quarters, solvent/cleaning areas, water treatment areas, processing plants and marine loading docks.
Made in USA Quality Lamp Options
1. Each unit dialectically tested. 2. Fixture arrives assembled and lamped to reduce installation time and cost. Flange type stainless steel mounts attached at each end of the fixture enables it to be simply secured to any surface. 3. Fixture housing constructed of glass fiber reinforced polyester. 4. Relamping done via stainless steel snap locking latches, which enable the operator to remove the door and access the lamps. 5. Lamp cover-diffuser constructed of high impact acrylic for corrosion resistance and lamp protection. 6. 1/2" or 3/4", threaded access hole for wiring conduit.

Shipping and delivery Information

Payment

American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

You may also like