Class 1 Division 2 Emergency LED Light - 4' 2 lamp - Battery Backup - Failsafe Lighting - UL 924

LARSON ELECTRONICSSKU: PL3-HALP-EMG-48-2L-LED
filler

Price:
Sale price$2,379.99

Description

Specifications / Additional Information
HALP-EMG-48-2L-LED Hazardous Area Failsafe Light Ratings/Approvals
Lamp Type: T8 Style LED Tubes Class I Division 2, Groups A, B, C, D
Dimensions (Surface): 49.975"-L x 7.975"-W x 5.1"-H Class II, Division 2, Groups F, G
Dimensions (Pendant): 49.731"-L x 7.2.05"-W x 5.425"-H UL 844
Weight: 8 Lbs UL 1598A Marine Type (Salt water)
Voltage: 120-277V AC 50/60 Hz Failsafe Operation w/ Battery Backup
Total Watts: 56 Watts Non-Corrosive Non-Metallic Housing
Watts on Battery: 28 Watts Meets US Coast Guard specifications
Efficiency: 125 Lumens per Watt Switch Leg for Powering Light On/Off
Total Lumens: 7,000 Listed for use in Canada
Efficiency on Battery: 125 Lumens per Watt
Lumens on Battery: 3,500
Color Temp: 5600K, 5000K, 4500K, 4000K, 3500K, 3000K, or 2700K
Color Rendering Index (CRI): 80
Beam Angle: 160° Horizontal - 120° Vertical
Lamp Life Expectancy: 50,000+ Hours
Housing Material: Polyester infused Fiberglass Housing
Lens Material: Acrylic Lens w/ Plastic Latch Clips
Battery Charge Current: 180mA (when fixture is not illuminating)
Battery Backup Runtime: 90 minute
Battery: High-Temperature, Maintenance Free Nickel-Cadmium Toll Free: 1-800-369-6671
Mounting: Flange type Surface Mount - Pendant Mount Intl: 1-214-616-6180
Wiring Hub: 1/2" or 3/4" threaded NPT Fax: 1-903-498-3364
Operating Temp Range: T4 Rated -30°C to +50°C
' Product Overview '
Made in the USA The HALP-EMG-48-2L-LED Hazardous Area LED Light Fixture is U.S./Canada approved Class 1 Division 2 Groups A, B, C and D, UL 1598A listed, has a T4C temperature rating, and is specifically designed to handle the rigors of wet and corrosive marine environments. This fixture is equipped with an added battery backup providing 90 minutes of emergency runtime. The HALP-EMG-48-2L-LED hazardous area fluorescent light fixture is designed for use in wet areas and saltwater/marine environments where corrosion resistance is critical to equipment longevity and safety. This Class 1 Division 2 rated fixture is constructed of non-corrosive materials including a polyester housing reinforced with glass fiber, a poured in gasket for reliable sealing and an impact resistant acrylic diffuser. Corrosion resistant stainless steel latches secure the lamp cover to the housing and provide a firm lock against the poured in seal to prevent drips and water intrusion. This fixture is UL 844 and UL 924 rated and Class 1 Division II, Groups A, B, C, D approved. The HALP-EMG-48-2L-LED also carries a UL 1598A outdoor marine rating and meets US Coast Guard specifications.
 Click Photo to Enlarge
This emergency LED light works, mounts and is wired like our HALP-48-2L-LED-G2 explosion proof LED light fixtures. The main difference is that we add a battery backup unit that adds emergency light functionality to the fixture. This hazardous area emergency light will run one bulb at 28 watts the standard UL suggested 90 minutes after power is lost at 3500 lumens. The light recharges the battery once electrical power is restored. Standard configuration includes a single emergency battery backup that is automatically recharged and kept in a ready state. Alternatively, we can configure this unit to be an emergnecy only fixture, where the light will only operate when power is lost. Please choose EMG only below for emergency only operation. The battery backup unit includes a switched leg for turning the light fixture on/off without kicking the unit into emergency mode. We have eliminated the ballast normally associated with fluorescent fixtures which reduces overall weight, increases lamp life to an extreme 50,000 hours and helps this LED fixture maintain a T4 temperature rating. The solid state design of the included LED lamps give this fixture superior resistance to damage from vibrations and extremes in temperature as well as a lamp service life over twice that of standard T8 bulbs. The 28 watt LED lamps produce more illumination than standard T8 bulbs, but draw only 3/4 of the current. The current generation of our LED T-series style bulbs produce 30% more light than standard T8 bulbs. This fixture is universal voltage capable (not multi-tap) and works on the following voltages: 120 Volt 60 HZ, 220 Volt 50 HZ, 240 Volt 60 HZ, 277 Volts 60 HZ. Our HAL-EMG-48-2L-LED-G2 light fixture is both U.S. and Canada approved. Standard Flange Mount Brackets: Flange type stainless steel mounts attached at each end of the fixture enables it to be simply secured to any surface. The mounts provide some shock absorbency protection while enabling the user to simply mount the fixture with the through-hole taps that protrude on each side of the fixture. The mounting holes are 36 9/16 inches on center apart along the top of this hazardous location light. The mounting holes are 7 inches on center across the top of the light. A sliding bracket mount is available so operators can retrofit this LED light fixture to use the pre-existing mounting holes from other fluorescent fixtures. Contact us for the sliding bracket option. Suggested Applications: The HALP-EMG-48-2L-G2 is designed for marine wet and damp locations, where corrosion resistant fluorescent lights are required. This includes petrochemical facilities, lubrication pits, oil drilling rigs, crew quarters, solvent/cleaning areas, water treatment areas, processing plants and marine loading docks.
Made in USA Quality Superior LED Benefits
1. Each unit dielectrically tested. 2. Fixture arrives assembled and lamped to reduce installation time and cost. Flange type stainless steel mounts attached at each end of the fixture enables it to be simply secured to any surface. 3. Fixture housing constructed of glass fiber reinforced polyester. 4. No ballast box.  No ballast to replace.  We simply run the black wire to one end of the bulb and white wire to the other. 5. Relamping done via 8 plastic locking latches which enables the operator to remove the door and access the lamps. 6. Lamp cover-diffuser constructed of high impact acrylic for corrosion resistance and lamp protection. 7. 1/2" or 3/4" threaded access hole for wiring conduit.       1. 50,000 hour lifespan. 2. Can SAVE 50% or more on energy. 3. Qualifies retrofit projects for financial incentives, including utility rebates, tax credits and energy loan programs. 4. Reduces energy use and prolongs life-spans of peripheral cooling units (A/C, refrigeration) 5. 100% recyclable. 6. No toxins-lead, mercury. 7. No UV light, infrared radiation or CO2 emissions. 8. Qualifies buildings for LEED and other sustainable business certifications. 9. Bright, even light maintains consistent color over time. 10. Instant on/off - No flickering, delays or buzzing. 11. Very good color rendering. 12. Vibration/impact resistant. 13. Significantly cooler operation. 14. Less frequent outages, higher output improves workplace safety.