Class 1 Division 2 Emergency Fluorescent Light - 4' 2 lamp - EMERGENCY ONLY

LARSON ELECTRONICSSKU: PL3-HALP-EMG-48-2L-T8-113
filler

Price:
Sale price$1,865.99

Description

Specifications / Additional Information
HALP-EMG-48-2L-T8-113 Hazardous Area U.L. Ratings
UL Listing: United States - Canada Class I Division 2, Groups A, B, C, D
Lamp Type: Fluorescent Class II, Division 2, Groups F, G
Dimensions: W-8.25 " L-52 " H-7" UL 844
Weight: 8 Lbs UL 924 - Failsafe battery backup
Voltage:Multi- 120V-60hz 220V-50hz 240V-60hz 277V-60hz UL 1598A Marine Type (Salt water)
Low Voltage Optional: 9-32VDC Meets USCG Specs
Total Watts: 64 watts T4 Temperature Rated
Total Lumens: T8 Bulbs 5,900 Switch Leg for Powering Light On/Off
Luminous Efficacy: 92 Lm/W cUL Listed for Canada
Lamp Life Expectancy: 20,000 Hours Emergency Only
Color Temp: 4100K- CRI-75 Meets US Coast Guard specifications.
Efficiency: 98 Lumens per Watt
Ambient Operating Temp Range: -30° C to +70° C
Operating Temp Range: T4C Rated
Battery Backup: 90 Minute Runtime
Surface Mounting: (2) Flange Type Aluminum Brackets Toll Free: 1-800-369-6671
Pendant Mounting: (2) 1/2" or 3/4" Threaded NPT Hubs on Either Side Intl: 1-214-616-6180
Wiring Hub: (2) 1/2" or 3/4" Threaded Hubs Fax: 1-903-498-3364
U.L Approval:    E-mail: 
' Product Overview '
Made in the USA The HALP-EMG-48-2L-T8-113 Hazardous Area Fluorescent Light Fixture from Larson Electronics is U.S./Canada UL Listed Class 1 Division 2 Groups A, B, C and D - UL 1598A listed, has a T4C temperatue rating and is specifically designed to handle the rigors of wet and corrosive marine environments. This fixture is equipped with an added battery backup providing 90 minutes of emergency runtime. The HALP-EMG-48-2L-T8-113 hazardous area fluorescent light fixture is designed for use in wet areas and saltwater-marine environments where corrosion resistance is critical to equipment longevity and safety. This Class 1 Division 2 rated fixture is constructed of non-corrosive materials including a polyester housing reinforced with glass fiber, a poured in gasket for reliable sealing and an impact resistant acrylic diffuser. Corrosion resistant stainless steel latches secure the lamp cover to the housing and provide a firm lock against the poured in seal to prevent drips and water intrusion. This fixture is UL 844 rated and Class 1 Division 2, Groups A, B, C, D approved. The HALP-EMG-48-2L-T8-113 also carries a UL 1598A outdoor marine rating and meets US Coast Guard specifications. This emergency fluorescent  light works, mounts and is wired like our HALP-48-2L explosion proof fluorescent light fixtures. The main difference is that we add a battery backup unit that adds emergency light functionality to the fixture. This hazardous area emergency light will illuminate only when there is a loss of power, and will run the standard UL suggested 90 minutes after power is lost. This hazardous area emergency light will run one bulb at 20 watts the standard UL suggested 90 minutes after power is lost at 3500 lumens. The light recharges the battery once electrical power is restored. Standard configuration includes a single emergency battery backup that is automatically recharged and kept in a ready state. Alternatively, we can configure this unit to be an emergnecy only fixture, where the light will only operate when power is lost. Please choose EMG only below for emergency only operation. The battery backup unit includes a switched leg for turning the light fixture on/off without kicking the unit into emergency mode.
Click Photo to Enlarge
NOTE ON LAMPS: This fixture comes equipped with F32-T8/841 – 32 Watt lamps producing 2,950 lumens per bulb, a 4100 Kelvin color and a 24,000 hour rated service life. Standard Flange Brackets: Flange type stainless steel mounts attached at each end of the fixture enables it to be simply secured to any surface. The mounts provide some shock absorbency protection while enabling the user to simply mount the fixture with the through-hole taps that protrude on each side of the fixture. The mounting holes are 36 9/16 inches on center apart along the top of this hazardous location light. The mounting holes are 7 inches on center across the top of the light. Pendant Mounting: This light fixture can hang from the ceiling suspected by rigid pipe. Each fixture is equipped with either two 1/2" or 3/4" NPT hubs on either side of the  fixture. Operators will bring rigid pipe down to the threaded mounting ups. The wiring is fed down through the rigid pipe to one of the NPT hubs and tied to the fixture`s lead wires to complete the electrical connection. The remaining pendant hub provides support for the opposite end of the fixture. Suggested Applications: The HALP-EMG-48-2L-T8-113 is designed for marine wet and damp locations, where corrosion resistant fluorescent lights are required. This includes petrochemical facilities, lubrication pits, oil drilling rigs, crew quarters, solvent/cleaning areas, water treatment areas, processing plants and marine loading docks.
Made in USA Quality Lamp Options
1. Each unit dialectically tested. 2. Fixture arrives assembled and lamped to reduce installation time and cost. Flange type stainless steel mounts attached at each end of the fixture enables it to be simply secured to any surface. 3. Fixture housing constructed of glass fiber reinforced polyester. 4. Relamping done via 6 stainless steel snap locking latches, which enable the operator to remove the door and access the lamps. 5. Lamp cover-diffuser constructed of high impact acrylic for corrosion resistance and lamp protection. 6. 1/2" or 3/4", threaded access hole for wiring conduit.  F32-T8/841 – 32 watt, 2950 lumens per bulb, 20,000 hours life, 4100 Kelvin color (Suffix –T8)

Shipping and delivery Information

Payment

American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

You may also like

Recently viewed