Larson 51" UV Air Duct Disinfection 2-Lamp Fixture - UV-C - Destroys Airborne Bacteria & Viruses - 120V - 28.6W Total UV Output - NEMA 3R Ballast Box

Larson ElectronicsSKU: PL3-IND-HVAC-DTW-UVC-R6-SS-48-2L-N3R-120V
filler

Price:
Sale price$3,314.00

Description

PuriLite suggests you place an order directly with us for large Larson orders due to the potential customization requirements. Please call us at 1(647) 254-9757 to place your order. If you prefer to place your order online, a PuriLite agent will be in touch with you to discuss any custom options.
This unit is Made In USA - Manufactured in Texas
*Please note: This product produces UV light. Make sure to follow all safety guidelines and protocols found in the user manual.
*
The IND-HVAC-DTW-UVC-R6-SS-48-2L-N3R-120V is a powerful sanitation solution for industrial sites and commercial facilities. Equipped with a pair of UVC fluorescent lamps, this system offers 28.6 total watts of UV output at a wavelength of 254nm. The lights have an expected lifespan of 8,000+ hours and emit a flood beam pattern. The IND-HVAC-DTW-UVC-R6-SS-48-2L-N3R-120V can be used continuously in air ducts such as those found in HVAC systems.
Operation:
This high output UV air duct disinfection system projects ultraviolet rays inside the air duct it is mounted in. The air flowing through the duct that passes through the UV rays is then sanitized. Bacteria and viruses present in the air that passes through the UV rays produced by the fixture are destroyed. The air moving through the duct is constantly being purified as it flows through the UV rays being produced by the fixture.
Construction:
The enclosure of the IND-HVAC-DTW-UVC-R6-SS-48-2L-N3R-120V is built from 304 stainless steel. An observation port allows for operators to check the status of the UV bulb(s) without removing the fixture from the air duct.
Mounting:
The IND-HVAC-DTW-UVC-R6-SS-48-2L-N3R-120V
is designed to be mounted inside an air duct. The system is intended to be mounted in a partial internal style with the bulb(s) being mounted inside of the air duct and the electronics mounted on the outside of the duct.
The IND-HVAC-DTW-UVC-R6-SS-48-2L-N3R-120V can be mounted on rooftop ducts and HVAC units. The design of this air duct disinfection system requires the ballast box to be mounted outside of the duct. For rooftop units, the externally mounted ballast box will be exposed to the elements. The IND-HVAC-DTW-UVC-R6-SS-48-2L-N3R-120V features a NEMA 3R ballast enclosure along with a gasketed mount between the ballast enclosure and mounting surface to keep moisture out. The indicator light is also outdoor rated.
Note on Environment
: Sunlight and visible light fixtures do not impact the effectiveness of the disinfecting on this UVC sanitation product. Metal halide, high pressure sodium, fluorescent, and LED light fixtures can be left on. The UV radiation emitted from this product is not disrupted by any type of lighting in the environment. Put simply, NO it DOES NOT need to be dark in the area you plan to disinfect. The UV radiation is harmful to the eyes and skin, and that is why you should not be in the area while it is in operation. Please see user manual for additional safety information.
Applications:
This ultraviolet UV air duct disinfection system can be used to continuously disinfect air of mold, allergens, airborne bacteria, viruses, and germs. The IND-HVAC-DTW-UVC-R6-SS-48-2L-N3R-120V is ideal for use in restaurants, hospitals, clinics, laboratories, nursing homes, schools, food processing facilities, office buildings, conference rooms, universities, clean rooms, and many more.
Larson Electronics is a manufacturer and as such can build stationary and portable transformer systems to your Specifications. Although we carry several models of power distribution transformer systems, we can deliver custom ordered units almost as quickly as our prebuilt units. If this model does not meet your needs, please contact us at 1(647) 254-9757 or
Contact info@purilite.ca
to discuss your specific requirements.

Specifications
Lamp Technology: UV-C Fluorescent
Exterior Housing Dimensions: 16-13/16"H x 8-1/8"W x 4-7/16"D
Depth (Inside Duct) for Partial Internal Mount: 51"
Weight: -
Voltage: 120V AC, 50/60 Hz
Wattage: 40W Per Lamp
Total Watts:  80W
UV Output: 14.3W per lamp 57.2W
Total UV Output: 57.2W
Irradiance (single lamp): 117 uW/cm2 @ 1 meter
Expected Lifespan: 8,000+ Hours
UV Wavelength: 254nm peak
Lamp Base: G13 (Medium Bi-Pin)
Replacement Lamp: FRL-48-1X-T8-40W-UV-C
Beam Angle: 360º
Light Configuration: Flood
Amps:  0.83A @ 120V
Ambient Operating Temp Range: -
Materials: 304 Stainless Steel Enclosure
Indicator Lights: Operational Light (confirms on) and Replace Lamp (lamp no longer functional) indicator lamps
Mounting: Partial Internal Duct Mount

Shipping and delivery Information

The PuriLite Peace of Mind 30-day money back guarantee

Payment

American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

You may also like

Recently viewed