LM-30-8-5S-4X150RT-LED-EW-SM-RD 600 Watt Three Stage LED Light Tower
Quick Summary
Lamp Type: LED
Mast Summary
Lamps: (4) 150 Watt LED Fixtures
8.83` to 30` Foot Light Mast
Total Watts: 600
Steel Construction
Total Lumens:Â 50,000Â
200` 10/4 Cable w/ Cord Reel
Mast Length: 8.83 feet - 30 feet
Removable Mast Head
Capacity: 150 lbs.
125 mph Wind Resistance
Materials: Steel
Electric Operation
Finish: Powder Coated or Galvanized - Gloss Blue
(4) 4` Slide-Out Outriggers w/ 1,200lb Jacks
Operation: 3,500lbs Electric Winches
Winch Voltage: 120V or 240V AC 50/60 Hz
LED Lamp Head Summary
Cable: 3/16 Aircraft CableETL Listed US & Canada
ETL Listed US & Canada
Mounting: 48" x 48" x 53" Carbon Steel Cube Frame
UL Rated for Marine Use
Shipping: Common Freight
LEL Approved
Â
Corrosion Resistant Aluminum Housing
Lamp Type: LED
Multi-Bank Drivers for Failsafe Performance
Voltage: Universal 100-277 VAC, 50/60Hz
Water Tight Connectors
Lighting Configuration: Flood Pattern
Temp Rating: T5 -40°C to +65°C
Color Temp: 5600K, 70-CRI
Lamp Life: 50,000+ Hours
Toll Free:Â 1-800-369-6671
Options: Length- Mounting-Fixtures/Call Us for Special Requirements
Intl:Â 1-214-616-6180
Fax:Â 1-903-498-3364
E-mail:Â
'
Product Overview
'
This unit is Made In USA - Manufactured in Texas
The Larson Electronics LM-30-8-5S-4X150RT-LED-EW-SM-RD skid mount electric light plant provides a safe and effective way for operators to quickly deploy 600 watts of intense lighting to elevations up to thirty feet. The four 150 watt LED lamps produce a wide spread of intense white light, allowing this unit to effectively cover large work areas with high quality illumination. The light tower features a rotating boom that allows for 360° of rotation, a removable mast head for storing mounted equipment when not in use, and is mounted to a cube frame with skid pockets and 4-corner pick eyes for easy transportation. When ordering this product, please choose between the following finishes: powder coated or galvanized.
*PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO LIGHT MASTS OR LIGHT TOWERS*
The LM-30-8-5S-4X150RT-LED-EW-SM-RD five stage telescoping steel light mast with electric winch from Larson Electronics is designed to quickly and safely deploy 600 watts of intense LED lighting in locations where elevated illumination is needed for maximum area coverage. This light boom can be extended to 30` for maximum area coverage and collapsed to 8.83` for applications where a footprint smaller is required. The tower is constructed of square steel tubing with a base section 5.92` in length and 6" by 6" by 3/16" thick, lower section 6.04` in length and 5" by 5" by 3/16" thick, middle section 6.19` in length and 4" by 4" by 1/8" thick, upper section 6.34` in length and 3" by 3" by 1/8" thick, and a top section 6.5` in length and 2" by 2" by 1/8" thick. Each section has a 1` overlap. The mast is elevated using an included 3,500 lbs. electric winch with 3/16" galvanized braided cable.
Included with this light tower are four of our wet area suitable high output LED fixtures producing a combined total of approximately 50,000 lumens at 600 watts. These lamps have a copper free aluminum alloy body that is powder coated or galvanized for added durability and an attractive aesthetic appearance. Special heat dissipating design in conjunction with LED technology helps this fixture achieve an excellent 50,000 hour rated lifespan with 80% lumen retention. Each floodlight is securely fastened to the light boom and each lamp includes a support bracket to help maintain lamp stability within its housing. The lamps are connected to the power source via a water tight male pin connector that attaches to a receptacle located on the end of the telescoping boom.
The light heads on this unit feature multiple LED drivers which help increase the operational life of the fixture. With traditional LED lights, in the event an LED array or driver fails, the entire fixture no longer illuminates. This new series of LED lamps contains twelve individual LED boards configured in a series of banks. Each bank contains two LED boards with an individual driver. In the event of a driver failure, only one bank of LEDs will be effected while the other banks will continue to operate. In the event that of an LED failure, the mating LED will continue to operate.
Click Image to Enlarge
Click Image to Enlarge
Click Image to Enlarge
LED Benefits: Unlike gas burning and arc type lamps that have glass bulbs, LEDs have no filaments or fragile housings to break during operation. Instead of heating a small filament or using a combination of gases to produce light, light emitting diodes (LEDs) use semi-conductive materials that illuminate when electric current applied and emitting light. With LED lights, there is no warm up time or cool down time before re-striking and provide instant illumination when powered on, adding to the reliability of LED technology. By nature, LED light sources run significantly cooler than traditional lamps, reducing the chance of accidental burns and increased temperatures due to heat emissions. This solid state design of light emitting diodes provides a more reliable, stable, durable, and energy efficient light source over traditional lighting.
Optional Finish
Glossy Blue Powder Coat
Galvanized
The tower and assembly comes powder coated or galvanized with a glossy blue finish for corrosion resistances and aesthetics. This mast is bolted onto a 1/8" thick carbon steel plate via six 1/2" anchor bolts. The mast and controls are secured within a cube-style frame constructed of 2" by 2" by 1/8" thick and measuring 48" wide by 48" long by 53" tall. Four 4` slide out outriggers with 1,200 lbs. manual crank leveling jacks allow operators to anchor the unit down, providing stability during deployment. Eight skid pockets allow this unit to be picked up from all four sides, and four-corner pick eyelets allow for stable deployment via crane operation. A 50" wide and 2" by 2" by 1/4" thick mounting plate is attached to the upper section of the mast which provides a strong and stable platform for the four metal halide fixtures.
The LM family of telescoping towers feature a proprietary mast guidance system, which provide increased stability during high winds. This light plant system can withstand winds up to 125+ mph when lowered to 8`, and up to 55 mph when fully extended. When elevated to its full upright position, the mast can be rotated a full 360°. By loosening the T-Handle, operators can rotate the mast with ease in either direction. The mast can be positioned in one of four different directions, and locked back in place by re-tightening the T-handle. The mast itself spins freely with ease, and can typically be rotated with a single hand.Â
The electric winch on this mast is offered in 120V or 240V AC 50/60 HZ. Additional voltage options are available at an additional charge. Larson Electronics can offer single phase and three phase AC winches, or low voltage DC winches.
Click Image to Enlarge
Click Image to Enlarge
Click Image to Enlarge
Mast Controls: The mast is operated via push button controls that are externally mounted on the control box exterior. All controls and electronics are housed within an aluminum NEMA 3R control panel. The lights are banked on two individual circuits, with the left half of the lights on one circuit and the right half on another, allowing operators to power two fixtures at 300 watts or all four fixtures at 600 watts depending on the lighting requirements.
Wiring & Cord Cap: This skid mounted LED flood lighting system is equipped with 200 foot of 10/4 chemical and abrasion resistant SOOW cord that is fitted with an industrial grade cord cap for easy connection to local electrical circuits. Cable management is provided via a manual roll up drum mounted within the steel cube frame that provides storage for the 200` power cable when not in use or during storage. Each end of this 200` 10/4 SOOW cable is terminated in L14-20 cord caps. Operators can utilize the build in cord reel to extend electrical power connections when in remote locations electrical connections are up to 200` away, or bypass this cord reel and plug directly into the L14-20P cord cap whip from the panel when the light tower is mounted closer to power sources. This light tower operates on 240V AC. The LM-30-8-5S-4X150RT-LED-EW-SM-RD also features weatherproof cord caps on break-aways between the light heads and control box, the electric winch and control box and between the control box and cord reel.
Larson Electronics can custom tailor these units to the customer’s requirements with longer sections and larger mounting plates. For example, the LM-25 is another model that reaches to a length of 25 feet, with a 15 foot lower section and a 10 foot upper section and a 4 foot wide upper mounting bracket. We also offer a choice of either the manual 1,000 lbs. hand winches included standard or optional electric winches.
Suggested Applications: Temporary lighting, construction sites, and security camera deployment. We can equip this mast with 1000W or 1500W Metal Halide lights or a wide variety of high powered LED lights with comparable power, including the , , or .
Shipping and delivery Information
Estimated delivery times range from 1 to 3 weeks, depending on your location, the product ordered and stock availability. External factors such as courier network disruptions can also impact delivery timelines. PuriLite strives to ship your purchase in the shortest possible time using industry standard courier services.
For any questions related to shipping and delivery, please call 1-844-787-5483, email us at info@purilite.ca or chat with us by clicking on the chat icon at the bottom right of this page.
Payment
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Refund Policy
Return & Refund Policy
For All non-Larson Products If you are not satisfied with a product, contact us by emailing or call 1-844-787-LITE within 30 days of receipt. A refund may be arranged excluding freight charges upon inspection. Returned merchandise must be shipped in original packaging, freight prepaid, unused, and in resalable condition, and are subject to 25% restocking fee. PuriLite inspects all returns and reserves the right to refuse credits on damaged, used or non-resalable items. Your only obligation is the freight charge and restocking fee, provided your return is complete with original packaging, all documentation, warranty cards, cables etc. PuriLite reserves the right to authorize product returns after 30 days have passed from the order date. If the product is accepted after this period, it is subject to a 25% restocking fee and credit will be issued toward future purchases only.
Shipping and handling charges are non-refundable for all returns. The customer may also be responsible for return shipping charges, insurance and shipment tracking for returned merchandise.
Once you place an order, the following products are non-returnable: custom-cut, customer built or special order items (such as matting, slings, cranes, prefab offices, buildings, mezzanines, assembled lockers and regularly stocked items such as generators, pressure washers, water and trash pumps, snow throwers, radio headsets, striping paint, line stripers, floor care machines, vacuums, custom fabric chairs, forklifts) your order is considered non-cancellable and any custom-cut, customer built or special order items purchased by you are also non-returnable. Consumable style bulbs or lamps are not returnable. There are no returns on any medical and/or sanitizing products for obvious safety reasons. This includes PPE (including masks), tests, thermometers, sprayers and UVC lighting of any kind (portable and surface).
Leased and hazardous items are also non-returnable. Contact customer service for a complete list of applicable products.
Larson product return policy Every order is tested prior to shipping. The product is tested before it is put into the shipping box, crate, pallet, etc. Larson take pictures and videos of every product for every order being shipped, and store these pictures and videos with the order number in our system. Because of the complexity of some of our products, we have a very limited return policy.
For safety reasons, we do not accept returns on any hazardous location, explosion proof or intrinsically safe products. Once these products leave the factory, we cannot be sure what happens to them. We must re-build and re-certify the units to specification to ensure that the next customer receives an item that is safe to use. This is cost prohibitive. For that reason, we do not accept returns on classified products. We do not accept returns on transformers, phase converters, or frequency converters. In order to install one of the aforementioned products, typically customers will modify the product (i.e. penetrate the housing to make connections, punch out knockouts, remove or damage tinning on lead wires during installation). Because we video test every unit before it ships to ensure the unit operates as described, we know when they leave here the units are operationally functional and meet the output voltage when supplied with the input voltage per the product specification. To be clear, we do not accept returns on these items under any circumstances for these reasons.
Products that are not addressed in the above two conditions must be returned in new, unused condition.
Below are some additional considerations:
Electrical/electronic parts are easily damaged by improper installation or testing. Because electronics are very sensitive to voltage overloads, it does not take much of a voltage spike to ruin a component. Because of this risk, all electrical products returned will undergo electrical testing and assessed a testing fee. This fee will be subtracted from the final return value.
Consumable style bulbs or lamps are not returnable.
Products that contain emergency backup components are subject to very narrow warranty terms and do not qualify for return. For customer convenience, we engage the battery pack prior to shipping all emergency backup products. Many times, particularly with hazardous location rated products, the battery packs are difficult to access and the customer generally plans to install the units shortly after receipt of the shipment. Battery backup components using older technologies (Nicad, NIMH, SLA, etc) will fail quickly if they do not maintain valid grid tie support. In other words, the batteries must receive a consistent maintained charge to perpetuate long lifespans. Battery backup products that are shelved (not installed) for periods greater than 3 weeks will likely fail and need replacement sooner. This replacement will not be covered under warranty. This can also occur is the units are installed but the grid tie option is not connected correctly. Customers can specify that they do not want the battery pack to be engaged at the time of ordering if they plan to shelve the units for long periods of time prior to installation.
There are many products on the site and not all pictures depict the exact configuration of each product. Many products are custom built and/or built on demand. In some cases, products are designed and not sold immediately and rendering may be used. In all cases, the end product is built to the specification listed and the pictures shown may be close approximations. Pictures are more likely to be close approximations with more complex products, including transformers, power distribution systems, control systems, light tower systems and other highly customizable products. In no way does the approximation validate a potential return. We always build to the specification. If customers have questions, they should ask prior to purchase to clarify.
There are no returns on any medical and/or sanitizing products for obvious safety reasons. This includes PPE (including masks), tests, thermometers, sprayers and UVC lighting of any kind (portable and surface)
Many international orders, specialty orders and other complex build orders require prepayment in advance. This prepayment represents a commitment to the order. Cancelling the order will result in a deduction from the original amount paid if any refund is available, since an investment of time and money is typically required to acquire materials and prepare the order. While not all orders in this category require prepayment, cancellation fees may apply to other build orders as well. The percentage of the deduction is at Larson’s discretion but usually ranges from 30 to 50%.
How to Return For all returns, you can email us at sales@purilite.ca. You will need the invoice number in the subject line of the email. You can use one of your preferred carriers. Please note that for freight collect shipments, you are responsible for order tracking once the freight is loaded onto the truck. In addition, PuriLite Industrial cannot assist you with filing damage claims with your carrier.
All returns must be authorized by PuriLite. A Return Authorization Number must be obtained from PuriLite Customer Service Department, and the client must provide the Invoice number at the time of the request. The following conditions must be met. Failure to do so could result in refusal of a shipment by us.
At the time of the return, goods must be a stock item with PuriLite and the returned quantity must correspond to the quantity of the original packaging
Approval and shipping destination must be obtained from PuriLite before returning goods;
Goods must be returned to the appropriate location within 10 working days after receiving the return authorization number;
The return authorization number and invoice number must be identified on the return address label;
Goods must be in their original packaging, arrive undamaged and in resalable form
All returns are to be sent prepaid;
Specially ordered goods are non returnable – these products are identified with a part number beginning with a // on quotes and invoices.
Goods damaged in transit must be signed as damaged by the receiver and carrier at the time of receipt of goods in order to request credit from PuriLite.
PuriLite reserves the right to deny any Returns or Claims if the above conditions are not met.
Orders for products affected by x-factor events such as viral outbreaks and other extreme circumstances CANNOT be returned once shipped and billed.