Tripp Lite PDU3XEVSR6L2230 24-Outlets PDU - Switched - NEMA L22-30P - 12 x IEC 60320 C13, 12 x IEC 60320 C19 - 415 V AC - Network (RJ-45) - 0U - Vertical - Rack-mountable - TAA Compliant
Tripp Lite PDU3XEVSR6L2230 24-Outlets PDU - Switched - NEMA L22-30P - 12 x IEC 60320 C13, 12 x IEC 60320 C19 - 415 V AC - Network (RJ-45) - 0U - Vertical - Rack-mountable - TAA Compliant
Tripp Lite PDU3XEVSR6L2230 24-Outlets PDU - Switched - NEMA L22-30P - 12 x IEC 60320 C13, 12 x IEC 60320 C19 - 415 V AC - Network (RJ-45) - 0U - Vertical - Rack-mountable - TAA Compliant
3-Phase PDU Distributes, Monitors and Manages Network-Grade Power
Recommended for data centers, server rooms and high-density network closets, this switched PDU provides advanced network control and remote power monitoring with the ability to turn on, turn off, reboot or lock out power to each outlet. You can more efficiently manage network power consumption and remotely reboot locked network items without having to visit the site. Reducing the number of on-site visits can help lower the cost of data center maintenance, thus lowering the 0U PDU's total cost of ownership.
24 Outlets Dispense AC Power to Connected Equipment
During normal operation, 24 individually controllable outlets-12 C13 and 12 C19-in six separately breakered load banks distribute AC power to rack equipment. Each 240V outlet is accompanied by an LED that illuminates when the outlet is ramped up and ready to be used. The outlets and banks can be individually monitored to ensure proper load balance and prevent downtime. Plug-lock insert sleeves are included to prevent connected cables from becoming accidentally dislodged.
Built-In LX Platform Network Management Card Allows Remote Access 24/7
The Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100/1000 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. The 0U PDU can receive IP address assignments via DHCP server (automatic) or static (manual) method.
Color Touchscreen LCD Offers Important Data at a Glance
An easy-to-navigate color touchscreen LCD reports network data, input current level per phase, and output current per load bank and per outlet with ±1% billing-grade accuracy. It also generates a unique QR code to allow read-only access to the 3-phase PDU via mobile device. If an EnviroSense2 module is connected to the PDU, the LCD also displays its status and environmental data, such as temperature and humidity.
Easy to Install Vertically in an EIA-Standard 19 in. Rack
The 70-inch 0U PDU mounts vertically using the pre-installed toolless mounting buttons or the included brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the PDU with outlets facing the rear for better airflow or equipment access. A six-foot cord with NEMA L22-30P 415V 3-phase input connects the switched PDU to a compatible AC power source, generator or protected UPS.
TAA-Compliant for GSA Schedule Purchases
The PDU3XEVSR6L2230 is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.
2-Year Warranty
The PDU3XEVSR6L2230 is backed by a 2-year warranty, ensuring reliability and performance.
- 12 C13 and 12 C19 240V outlets distribute AC power to connected equipment
- Built-in Java-free HTML5-based LX Platform interface allows you 24/7 remote access
- Remote power monitoring and control reduces on-site visits and maintenance costs
- 6 ft. cord with NEMA L22-30P 415V 3-phase input connects to compatible AC source
- Color touchscreen LCD provides current levels, environmental data and network info
Network (RJ-45) | Yes |
Management |
|
Limited Warranty | 2 Year |
Package Contents |
|
Environmentally Friendly | Yes |
Environmental Certification | RoHS |
TAA Compliant | Yes |
Input Voltage | 415 V AC |
Output Voltage | 240 V AC |
Input Current | 24 A |
Power Rating (Watt) | 17.30 kW |
Product Type | PDU |
Manufacturer Part Number | PDU3XEVSR6L2230 |
Manufacturer Website Address | http://www.tripplite.com |
Manufacturer | Tripp Lite |
Product Model | PDU3XEVSR6L2230 |
Product Name | PDU3XEVSR6L2230 24-Outlets PDU |
Brand Name | Tripp Lite |
Weight (Approximate) | 7.67 kg |
Mount Type | Rack-mountable |
Rack Height | 0U |
Height | 70" (1778 mm) |
Width | 2.17" (55.12 mm) |
Depth | 2.52" (64.01 mm) |
Mounting Orientation | Vertical |
Protection Type | Overload Protection |
Plug/Connector Type | NEMA L22-30P |
Phase | Three Phase |
Receptacle Type | IEC 60320 C13 |
IEC 60320 C19 | |
PDU Type | Switched |
Receptacle Detail | 12 x IEC 60320 C19 |
12 x IEC 60320 C13 |
Shipping and delivery Information
Shipping and delivery Information
Estimated delivery times range from same day to 2 weeks, depending on your location, the product ordered and stock availability. External factors such as courier network disruptions can also impact delivery timelines. PuriLite strives to ship your purchase in the shortest possible time using industry standard courier services.
For any questions related to shipping and delivery, please call +1-647-254-9757, email us at info@purilite.ca or chat with us by clicking on the chat icon at the bottom right of this page.
The PuriLite Peace of Mind 30-day money back guarantee
The PuriLite Peace of Mind 30-day money back guarantee
Enjoy our peace of mind 30-day money back guarantee on all products. If you are not satisfied with any of our products, your item is eligible for return within 30 days of purchase, subject to the terms & conditions below.
1. Goods must be returned in new & unused conditions with all original packaging. Do not write or put stickers on original packaging.
2. Any shipping charges incurred by Purilite to ship the product to your destination and returns from your location to our warehouse, in case of refused shipments, are non-refundable.
3. Depending on the product purchased, the client will be responsible for shipping product back to our warehouses.
4. Restocking fees map apply once inspected at our warehouse. All credits are subject to final inspection of good upon arrival at our destination.
5. Defective products are eligible for return.
If you purchased a product and did not receive the parcel, please contact us at sales@purilite.ca and we would be happy to assist you right away! PuriLite uses secure and well-established carriers (such as Canada Post, FedEx, Purolator, UPS etc.) to ensure your purchase is delivered successfully to your doorstep. All items are delivered with a tracking ID and are traceable. If your parcel was indeed not received, we will issue back a 100% refund.
Shop with confidence knowing that your purchase is protected, and your peace of mind is our commitment. Thank you for choosing PuriLite!
Sustainability & Ethical Sourcing
Sustainability & Ethical Sourcing
At PuriLite, we believe innovation should go hand-in-hand with responsibility. That’s why we’re committed to creating products that not only perform well but are also thoughtfully made with the planet and people in mind.
♻️ Sustainable Practices
- We prioritize durable materials that extend the product life cycle and reduce waste.
- Where possible, our packaging is made from recyclable or minimal-waste materials, helping to reduce environmental impact.
- Many of our electronic products are designed with energy efficiency in mind to minimize power consumption.
🤝 Ethical Sourcing
- We partner with manufacturers who fillow fair labor practices, ensuring safe working conditions and fair wages for their workers.
- All suppliers are carefully vetted for compliance with environmental and ethical standards.
- We avoid the use of materials from conflict zones and work to reduce the environmental footprint across our supply chain.
🌍 Our Ongoing Commitment
We're actively exploring new ways to improve—from using eco-certified components to optimizing our logistics for a lower carbon footprint. Every small step counts, and we’re committed to doing our part in building a more sustainable future.
Share