15 KVA Transformer - 480V Delta Primary - 208Y/120 Wye-N Secondary - C1D1&2/C2D1&2 Explosion Proof Enclosure

LARSON ELECTRONICSSKU: PL3-EPL-TX-CS-ISX-480D-15KVA-208Y.120
filler

Price:
Sale price$57,450.00

Description

Specifications / Additional Information
EPL-TX-CS-ISX-480D-15KVA-208Y.120 Transformer w/ Explosion Proof Enclosure Ratings
Phase: Three Phase Listed for NEC and CEC
Frequency: 60 Hz Class I, Divisions 1 & 2, Groups B, C, D
kVA: 15 Class I, Zones 1 & 2, Groups IIB+H2, IIA
Primary Voltage: 480 V Delta Class II, Divisions 1 & 2, Groups E, F, G
Primary Configuration: Encapsulated Class III, Divisions 1 & 2
Secondary Voltage: 280Y/120 V Wye-N NEMA 3R, 4, 7, 9
Taps: 2 x 5% FCBN UL 886 Certified
Impedance: 2.3% UL 698 Certified
Winding Material: Aluminum UL 1203 Certified
Insulation: 180° CSA C22.2 No 30 Certified
Temperature Rise: 135°
Termination: Leadwires
Sound Level: Meets NEMA ST-20 Standards
Enclosure Material: Cast Aluminum
Hubs: (2) 3/4" NPT Hubs on North Side, (2) 3/4" NPT Hubs on South Side
Dimensions: 19.00"H x 21.00"W x 22.00"D
Weight: 545 lb
' Product Overview '
The EPL-TX-CS-ISX-480D-15KVA-208Y.120 Three Phase Transformer from Larson Electronics is powerful, reliable and designed with the environment in mind. Suitable for both indoor and outdoor applications, the EPL-TX-CS-ISX-480D-15KVA-208Y.120 provides increased reliablity and protection against critical equipment failures. The lower operating costs, lower heat emissions and lower cost of ownership make this transformer ideal for a wide range of applications and businesses. The transformer of the EPL-TX-CS-ISX-480D-15KVA-208Y.120 is mounted in an explosion proof enclosure that is rated for Class I and II Divisions 1 & 2 hazardous locations. *PLEASE NOTE: ANY FREE SHIPPING OFFERS DO NOT APPLY TO POWER DISTRIBUTION PANELS, TRANSFORMERS, OR SUBSTATIONS* Transformer Features: With a transformer rating of 15 kVA, the EPL-TX-CS-ISX-480D-15KVA-208Y.120 transformer is a three phase unit with a primary voltage of 480 V Delta. It also provides a secondary voltage of 208Y/120 V Wye-N. Featuring robust construction, this unit's cores are manufactured with non-aging, cold-rolled silicon steel laminations using state of the art technology. The EPL-TX-CS-ISX-480D-15KVA-208Y.120 is encapsulated to seal out moisture and airborne contaminants. This unit boasts a low cost of ownership and is highly energy efficient. Lower heat emissions mean less cooling is needed as well. The explosion proof enclosure makes the unit suitable for both indoor and outdoor applications located within hazardous areas and it can be surface mounted via four ears with two on each side of the enclosure. The unit also features a 180°C insulation system with a 135° temperature rise and meets NEMA ST-20 sound level standards. Enclosure: The explosion proof enclosure on the EPL-TX-CS-ISX-480D-15KVA-208Y.120 provides operators with a Class I, II, and III Divisions 1 and 2 transformer. This explosion proof enclosure is made of cast aluminum, is equipped with stainless steel hinge and bolts, includes a watertight gasket for a NEMA 4X protection rating and is ideal for indoor or outdoor applications where flammable vapors, gases, or dusts exist or stand the potential to exist. The enclosure features two 3/4" NPT hubs on the north side and two 3/4" NPT hubs on the south side which enable operators to bring power in and out. Benefits: The EPL-TX-CS-ISX-480D-15KVA-208Y.120 distribution transformer offers many benefits to the consumer. Precision cut aluminum transformer winding material help to improve performance. The close tolerances used during manufacturing also eliminates burrs which hinder performance. Each core is specially coated to prevent the ingress of moisture and are electrically balanced to minimize axial forces during short circuit situations. This transformer provides owners with significant energy savings as well as offering environmental benefits. Higher efficiency not only extends the life of the transformer, but also turn into cost savings for owners in the form of lower energy bills and decreased cost of ownership. Integrated floor and wall mounting brackets make installation fast and easy and the offset outward facing floor installation holes allow for easy power tool access. Applications: Power supplies for Class I, II, and III Divisions 1 & 2 hazardous locations. Larson Electronics is a manufacturer and as such can build stationary and portable transformer systems to your specifications. Although we carry several models of power distribution transformer systems, we can deliver custom ordered units almost as quickly as our prebuilt units. If this model does not meet your needs, please contact us at 1-800-369-6671 or to discuss your specific requirements.

Shipping and delivery Information

The PuriLite Peace of Mind 30-day money back guarantee

Payment

American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

You may also like

Recently viewed