Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs

LARSON ELECTRONICSSKU: PL3-HAL-ANC-48-2L-LED-BMSW-D-V2
filler

Price:
Sale price$4,716.00

Description

Specifications / Additional Information
HAL-ANC-48-2L-LED-BMSW-D-V2 Hazardous Area Ratings/Approvals
UL Listing: United States - Canada Class I Division 2, Groups A, B, C & D
Dimensions: 51.1"-L x 7.09"-W x 8.65"-H UL 844
Weight: 22.2 Lbs UL 1598A Marine Type
Total Watts: 56 watts (28 Watts Per Lamp) cUL Listed for Canada
Total Lumens: 7,000 (3,500 Per Lamp) T4 Temperature Rating
Voltage: Universal 120-277V AC 50/60Hz Meets USCG Specs
LED Lamp Life Expectancy: 50,000 Hours California Title 24 Compliant
Luminous Efficacy: 120 Lumens per Watt 0-10V Dimmable
Operating Temp Range: T4A rated -40°C to +65°C Password Protected Network Controls
Beam Angle: 150° No Programming Required
Color Temp: 5600K, 4500K, or 3000K Modbus TCP/IP Connectivity
Color Rendering Index: >80  
Beam Angle: 150°  
Lighting Configuration: Flood Pattern  
Power Efficiency: 90%  
Power Factor: >0.95  
Materials: Sheet aluminum housing, acrylic lens  
Mounting: Back Mount Swivel Bracket  
Wiring Hub: 1/2" or 3/4` Threaded  
 
Network Controller Specs  
Dimensions: 1.41" x 3.88" x 3.1"  
Weight: 5 oz  
Network Type: 10/100 Base-T Ethernet Port  
Protocols: HTTP, XML, Modbus TCP/IP  
Power Supply: 9-28V DC  
Digital Input: (1) Optically Isolated 4-26V DC  
Current: 950uA @ 4V, 8.5mA @ 26V  
Relay Contacts: (1) SPDT - 240V AC/30V DC Max @ 12A  
Relay Modes: On/Off or Pulsed  
Pulse Timer Duration: 0.1 to 86,400 Seconds  
Input Functions: Monitor, Local Relay Control, Remote Relay Control  
LED Indicators: (4) Digital Input Voltage Applied, Relay Coil Energized, Network Linked, Network Activity
Operating Temperature: -40°C to 57°C
Housing Material: Lexan 940 Polycarbonate Plastic Toll Free: 1-800-369-6671
Mount: Surface, Wall or DIN Rail
Password Protection: Yes @ Setup (Base 64 Encoding, 10 Characters)
Connectors: 3-position Removable (Relay- C, NO, NC), 5-position Removable (Power/Input), 8-pin RJ-45 (Network)
' Product Overview '
Made in the USA The Larson Electronics HAL-ANC-48-2L-LED-BMSW-D-V2 Hazardous Location LED Pivoting Light is a U.S./Canada UL Listed connected lighting solution for Class I Division 2 Groups A, B, C and D locations. Modbus TCP/IP network capable, this hazardous location LED light carries a United States Coast Guard approval, making it ideal for applications such as oil rigs, ships, offshore applications, petrochemical, manufacturing, chemical storage, and water treatment centers. Operators can setup remote access, controls and configurations using the Modbus TCP/IP network controller (via a standard web browser). This four foot long, two lamp, 0-10V dimmable LED fixture is ideal for operators seeking a top quality hazardous location light that will reduce operating costs, improve lighting quality and reduce downtime incurred from frequent servicing intervals. The HAL-ANC-48-2L-LED-BMSW-D-V2 fixture is a 4 foot long, 2 lamp, Class I Division 2 Groups A, B, C and D hazardous area LED light that takes the reliability and efficiency of a fluorescent fixture and adds even longer lamp life and efficiency with high output LEDs. This fixture is T4A temperature rated and comes standard with our high power 28 watt LED lamps. The lamps are protected by a powder coated aluminum frame and shatter and heat resistant clear acrylic lens secured with ten zinc coated steel draw latches. We now offer our second generation dimmable LED tube lamps with this fixture which have increased this hazardous location light`s performance. This two lamp HAZLOC LED linear fixture is lighter in weight and produces more light than hazardous location fluorescent fixtures. The four foot long LED tube design bulbs included with this unit are rated at 50,000+ hours of service life, which is over twice as long as standard T8 bulbs. This LED light fixture features 0-10V dimming capabilities. This gives operators the ability to manually adjust the brightness of the LED lamp quickly and easily. The 0-10V dimming allows for adjustments to fit the brightness needs of any lighting situation. A 0-10V dimmable light works through the use of a DC control signal that ranges between zero and ten volts. The basic idea is that at 10 volts of input the light is at its brightest level with 0 volts being the lowest possible dimness setting. The smooth, continuous and flicker-free dimming of a 0-10V dimmable LED light is ideal for a wide range of different lighting applications. This fixture carries a T4A temperature rating and is U.L. 595 and UL 1598A Marine Type approved for use marine environments. The fixture is constructed of copper free sheet aluminum and powder coated. The lamp reflector is corrosion resistant heavy gauge aluminum and coated with a high gloss reflective finish. The HAL-48-2L-LED-G2 is weatherproof and provides operators in hazardous locations with a highly efficient, reliable and affordable lighting solution for open areas where flammable chemicals and vapors may occasionally be present. Aevum Network Controlled Lighting Solution: The Aevum Network Controlled Lighting Solution from Larson Electronics enables connected and intelligent illumination using cutting-edge and existing networks. Using Modbus TCP/IP or DALI (for fixtures with dimming features), businesses can seamlessly control lights and sensors from remote locations, without traditional light switches. Web-based panels facilitate real-time monitoring of connected equipment and allows operators to switch units on/off, configure activation settings and more. Businesses may utilize their own systems and software with these controllers, ensuring robust flexibility and cost savings (no contracts). The Aevum Network Controlled Lighting Solution can improve productivity in the workplace by automating basic lighting controls and making lighting controls widely accessible in the facility, via local networks or the internet. Operators also have the option to monitor the status of fixtures from a remote location, which can improve maintenance and reduce downtimes. Controls: Controls for the LED fixture is accessible using a web-based control panel. Compatible with HTTP, XML, or Modbus TCP/IP protocols, network configuration is accessible using web-based pages (no programming required). Operators can monitor or setup controls from a remote area using the internet or local IP network and any standard web browser. Functions and controls include: on/off, pulse and monitor. LED indicator lights on the device provide the real-time information about digital input voltage, relay coil, network status and network activity. Password protection for the setup page is available (10 characters maximum).
Click Photo to Enlarge
We have eliminated the ballast normally associated with fluorescent fixtures which reduces overall weight and overall complexity of installation. There is no ballast in this unit and the included LED lamps have a 50,000+ hour service life, both of which result in extreme efficiency and greatly reduced maintenance costs. The solid state design of the LED lamps give this fixture superior resistance to damage from vibration, extremes in temperature and a lamp service life over twice that of standard fluorescent bulbs. This second generation lamp is offered in 5600K cool white, 4500K natural white, and 3000K warm white. Our standard unit ships with 5600K unless different color temperature is specified. Unlike the glass tube design of traditional fluorescent lamps, these LED T-Style lamps have no filaments or fragile housings to break during operation. Instead of using a combination of gases to produce light, light emitting diodes (LEDs) use semi-conductive materials that illuminate when electric current applied and emitting light. The LED assembly is mounted to the "tube" constructed from extruded aluminum, with a polycarbonate lens protecting the LEDs. With LED lights, there is no warm up time or cool down time before re-striking and provide instant illumination when powered on, adding to the reliability of LED technology. By nature, LED light sources run significantly cooler than fluorescent lamps, reducing the chance of accidental burns and increased temperatures due to heat emissions. This solid state design of light emitting diodes provides a more reliable, stable, durable, and energy efficient light source over traditional fluorescent lighting. The 28 watt LED lamps produce 30% more illumination than standard T8 bulbs while offering lower amp draw and increased reliability. Each lamp produces 3,500 lumens at 125 lumens per watt, for a combined 7,000 total lumen light output. A HAL-48-2L-T8 hazardous location fluorescent light, with a combined total of 64 watts, draws 0.54 amps at 120 volts AC. This LED version of the same light, with a total of 56 watts, draws only 0.47 amps at 120 volts AC. The HAL-ANC-48-2L-LED-BMSW-D-V2 is universal voltage, not multi-tap, and operates on any voltage from 100V to 277V AC 50/60hz without any modifications. Standard 0-10V dimming switches (mounted outside the hazardous location) are compatible with these hazardous location fixtures. Larson Electronics offers an for mounting within the hazardous location. Network: The network controller is equipped with one optically-isolated digital input and one SPDT relay contact. Compatible with 9-28V DC, the unit features a 3-position removable relay (N, NO, NC), a 5-position removable power/inputs and an 8-pin RJ-45 port for network connections. Operators can mount the device on walls, surfaces or din rails for space-saving benefits.
Energy Consumption Comparison
T5HO T8 LED
Wattage 108 watts 64 watts 56 watts
Amp Draw @ 120V AC 0.90 amps 0.54 amps 0.47 amps
Amp Draw @ 220V AC 0.49 amps 0.29 amps 0.25 amps
Amp Draw @ 240V AC 0.45 amps 0.27 amps 0.23 amps
Amp Draw @ 277V AC 0.39 amps 0.24 amps 0.20 amps
Lamp Life Expectancy 20,000 hours 24,000 hours 50,000 hours
Color Temperature 5000K / 4100K 4100K 5600K
Operation cost per year (12hs/day @ 12c/kWh) $56.77 $33.64 $29.43
Mounting Options: Unless otherwise specified, our standard, most popular configuration is the bracket end mounting shown enlarged below. We also offer a pendant mount for those needing to suspend the fixture away from the ceiling surface (i.e. suspend from pipe or conduit). Additional mounting configurations can be customized to meet the requirements on the application. Please contact us for special mounting configurations. Standard Surface Mount Brackets: Each L bracket is cinched to the bracket mounting peg on each side of the light. The angle of the bracket is set by tightening two bolts on either side of the bracket. The bolts act as a set screw. The bracket itself is mounted via a single bolt hole at the top the bracket. There are two brackets. Once the brackets are mounted to a surface (ceiling, floor or wall), the light fixture can be pivoted by loosening the that hold the bracket to the mounting peg. This fixture allows 45° of pivot from the 90° point. Suggested Applications: Modbus TCP/IP lighting networks, remote lighting networks, aircraft maintenance, oil drilling rigs, refineries, marine and salt water environments, ships, tankers, offshore, solvent and cleaning areas, chemical manufacturing, waste treatment plants, gas processing plants.

Shipping and delivery Information

The PuriLite Peace of Mind 30-day money back guarantee

Payment

American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

You may also like

Recently viewed