Explosion Proof Hydrogen Sulfide Gas Sensor - 0-100 ppm - HS2 Analog
Explosion Proof Hydrogen Sulfide Gas Sensor - 0-100 ppm - HS2 Analog
EXP-SNR-TG-HS2-ITS-ALG-E100 HS2 Sensor | Features/Ratings |
Listing: NRTL Listed for United States and Canada | Class I, Divisions 1 & 2, Groups B, C, D |
Dimensions: 7.12" x 5.43" x 5.11" | HC Sensor |
Weight: 4 lbs | LCD Graphic Display |
Gas Type: Hydrocarbon (Hydrogen Sulfide, Pentane) | Non-Intrusive Magnetic Operation |
Transmitter Type: Electrochemical Without Arms | Internal Data Logger |
Voltage: 12V DC to 30V DC | Â |
Amps: 250mA @ 24V DC Maximum, 3-wire Mode | Â |
Sensor Holder: Integral Holder | Â |
Output: Analog | Â |
PPM Detection Range: 0-100 ppm | Â |
Sensor Sensitivity: 120 Lm/W | Â |
Response Time: T90 < 30 Seconds | Â |
Accuracy/Repeatability: ±2%LEL (0.1%VOL) Methane |  |
Zero/Span Drift: ±1%LEL (0.05%VOL) Methane, per month |  |
AO Range: 4mA is 0%LEL, 20mA is 100%LEL (Programmable Down to 50%LEL) | Â |
Alarm Relays: (3) SPST | Â |
Contact Rating: 5A @ 250V AC, Resistive Load | Â |
Relay Coils: Normally Energized or De-energized, Programmable | Â |
Controls: Non-intrusive (4 Magnetic Switches on Front of Transmitter) | Â |
Serial Interface: HART 1200 Baud Modem Interface, Registered DDL File or Modbus 1200-600,14.4k,28.8k, RS232/RS485 or ASCII Text Output for Printing Data Log | Â |
Output Range: Scalable 4-20 mA | |
Operational Temp Range: >-25º to +55ºC | |
Operational RH Range: 0-95% Non-condensing | Toll Free:Â 1-800-369-6671 |
Housing: Cast Aluminum | |
Mounting: Surface (2) 5/16"-D Openings | |
Hub Size: 3/4" NPT Threaded |
The EXP-SNR-TG-HS2-ITS-ALG-E100 HS2 Sensor, is a Class 1 Division 1 explosion proof toxic gas transmitter fitted with a sensor, that offers users a unique sensor response testing system, reliable in hazardous locations. This testing system verifies response checks with real gas sample generated on demand, and features an easy to see LCD graphics display, internal data logger, alarms and may additional features that simplify installation, operation and maintenance. This explosion proof gas sensor is Class I, Divisions 1 & 2 certified and is fitted with a hydrocarbon sensor that detects 0-100 ppm. The EXP-SNR-TG-HS2-ITS-ALG-E100 is built with cast aluminum housing, ideal for detecting gas leaks and other emissions and as a control system for oil rigs, manufacturing processes and other hazardous locations where explosive gases are present. The EXP-SNR-TG-HS2-ITS-ALG-E100 toxic gas sensor that is configured to detect hydrocarbon vapors of Hydrogen Sulfide or Pentane within a 0-100 ppm (parts per million) concentration, and includes an electrochemical transmitter, an integral sensor holder and non-digital output. An LCD graphics display shows gas concentrations in large, easy to read numbers and also provides operators with alarm indication and menus to set up operating parameters. A backlight is available for use when 3-wire mode is used. This sensor also includes an internal data logger which stores measured gas values at intervals chosen by the user, which can be pulled up on the LCD screen at any point, or downloaded using an interface. This hydrocarbon sensor has non-intrusive operation, allowing operators to calibrate, view data, set up alarms and complete other tasks with a magnetic tool, eliminating the need to open the sensor€™s enclosure. All program settings are password protected. Also included with this sensor is a scalable 4-20 mA programmable output range, three internal alarm relays transmitter, and analog output set to user defined values for loop testing without needing to apply gas to the sensor. Designed to operate on 12V DC to 30V DC, the unit contains three SPST alarm relays. The contacts are rated at 5A @ 250V AC, resistive load. During use, the sensor can detect hazardous gas with ±2%LEL (0.1%VOL) accuracy/repeatability. Zero/span drift is ±1%LEL (0.05%VOL). This device features a HART® 1200 baud modem interface, registered DDL file or Modbus ® 1200-600,14.4k,28.8k, RS232/RS485 or ASCII text output (for printing data log) serial interface. The EXP-SNR-TG-HS2-ITS-ALG-E100 is fitted with a HS2 sensor, which plugs directly to the transmitter. This gas sensor is used to detect a wide variety of HS2, which can be calibrated by the user based on application. This gas detector contains a sensor, amplifier and memory module in one unit, allowing it to be calibrated independently and plugged into any detector for immediate use with no adjustments needed. Hubs: This explosion proof sensor contains a 3/4" NPT threaded opening at the bottom of the unit. Mounting: The EXP-SNR-TG-HS2-ITS-ALG-E100 can be secured on surfaces via two 5/16" mounting holes. |
Shipping and delivery Information
Shipping and delivery Information
Estimated delivery times range from same day to 2 weeks, depending on your location, the product ordered and stock availability. External factors such as courier network disruptions can also impact delivery timelines. PuriLite strives to ship your purchase in the shortest possible time using industry standard courier services.
For any questions related to shipping and delivery, please call +1-647-254-9757, email us at info@purilite.ca or chat with us by clicking on the chat icon at the bottom right of this page.
The PuriLite Peace of Mind 30-day money back guarantee
The PuriLite Peace of Mind 30-day money back guarantee
Enjoy our peace of mind 30-day money back guarantee on all products. If you are not satisfied with any of our products, your item is eligible for return within 30 days of purchase, subject to the terms & conditions below.
1. Goods must be returned in new & unused conditions with all original packaging. Do not write or put stickers on original packaging.
2. Any shipping charges incurred by Purilite to ship the product to your destination and returns from your location to our warehouse, in case of refused shipments, are non-refundable.
3. Depending on the product purchased, the client will be responsible for shipping product back to our warehouses.
4. Restocking fees map apply once inspected at our warehouse. All credits are subject to final inspection of good upon arrival at our destination.
5. Defective products are eligible for return.
If you purchased a product and did not receive the parcel, please contact us at sales@purilite.ca and we would be happy to assist you right away! PuriLite uses secure and well-established carriers (such as Canada Post, FedEx, Purolator, UPS etc.) to ensure your purchase is delivered successfully to your doorstep. All items are delivered with a tracking ID and are traceable. If your parcel was indeed not received, we will issue back a 100% refund.
Shop with confidence knowing that your purchase is protected, and your peace of mind is our commitment. Thank you for choosing PuriLite!
Sustainability & Ethical Sourcing
Sustainability & Ethical Sourcing
At PuriLite, we believe innovation should go hand-in-hand with responsibility. That’s why we’re committed to creating products that not only perform well but are also thoughtfully made with the planet and people in mind.
♻️ Sustainable Practices
- We prioritize durable materials that extend the product life cycle and reduce waste.
- Where possible, our packaging is made from recyclable or minimal-waste materials, helping to reduce environmental impact.
- Many of our electronic products are designed with energy efficiency in mind to minimize power consumption.
🤝 Ethical Sourcing
- We partner with manufacturers who fillow fair labor practices, ensuring safe working conditions and fair wages for their workers.
- All suppliers are carefully vetted for compliance with environmental and ethical standards.
- We avoid the use of materials from conflict zones and work to reduce the environmental footprint across our supply chain.
🌍 Our Ongoing Commitment
We're actively exploring new ways to improve—from using eco-certified components to optimizing our logistics for a lower carbon footprint. Every small step counts, and we’re committed to doing our part in building a more sustainable future.
Share