Indirect UV Air Disinfection Fixture - UV-C - Destroys Airborne Bacteria & Viruses - 120V - 7.5W Total UV Output - Wall Mount

LARSON ELECTRONICSSKU: PL3-IND-AH-UVC-LF-24-SF-WLM-120V
filler

Precio:
Precio de venta$3,222.00

Descripción

Specifications / Additional Information
This unit is Made In USA - Manufactured in Texas
IND-AH-UVC-LF-24-SF-WLM-120V Indirect UV Air Disinfection Fixture Ratings/Features
Lamp Technology: UV-C Fluorescent T10 Bulb Shape
Dimensions: 24.00"L x 4.50"W x 7.875"H Short-wave Germicidal Light
Weight: 38 lb Destroys Airborne Bacteria and Viruses
Voltage: 120 V AC, 50/60 Hz EPA Reg. No 98409-1
Total Watts: 20W EPA Est. No. 98409-TX-1
Total UV Output: 7.5W  
Expected Lifespan: 8,000+ Hours
UV Wavelength: 254nm
Lamp Base: Medium Bi-Pin
Replacement Lamp: -
Beam Angle: 180º
Light Configuration: Flood Special Orders - Requirements
Amps: -
Ambient Operating Temp Range: -
Materials: 304 Stainless Steel Enclosure
Front Panel: Louvers
Mounting: Wall Mount
***PLEASE NOTE: UV-C light can cause temporary or permanent loss of vision, and temporary acute redness or ulceration (mild to severe sunburn) to exposed skin. To prevent exposure, do not operate the device in any application that allows UV-C light to be visible during operation. NEVER LOOK DIRECTLY AT THE BULB OR DISINFECTING TARGET ZONE. DO NOT touch bulb with bare hands. The oils in your skin will damage the lamp. Fingerprints will result in reduced performance and significantly reduce the lifespan of the lamp unless they are removed with alcohol. Please read instruction manual for UV safety requirements before operating.***
' Product Overview '
This unit is Made In USA - Manufactured in Texas The IND-AH-UVC-LF-24-SF-WLM-120V from Larson Electronics is an Indirect Ultraviolet Air Disinfection Fixture that works to disinfect the upper room air of occupied spaces via germicidal ultraviolet (UV) rays. This unit helps to reduce the risk of cross infection and minimizes the exposure of occupants to infectious airborne microbes. This stainless steel air disinfection unit features a single 20 watt UV bulb that produces 7.5 watts of UV output at a wavelength of 254nm. The IND-AH-UVC-LF-24-SF-WLM-120V is a wall mounted unit and operates on 120 V AC current. *Please note: This product produces UV light. Make sure to follow all safety guidelines and protocols found in the user manual. UVC light in the proper setting kills up to 99.9% of viruses, mold, spores and bacteria. * The IND-AH-UVC-LF-24-SF-WLM-120V is a powerful sanitation solution for industrial sites and commercial facilities. Equipped with a UVC fluorescent lamp, this system offers 7.5 watts of UV output at a wavelength of 254nm. The lights have an expected lifespan of 8,000+ hours and emit a flood beam pattern. The IND-AH-UVC-LF-24-SF-WLM-120V can be used continuously in occupied areas such as restaurants, public spaces, and office buildings. Operation: This indirect UV air disinfection fixture projects ultraviolet rays across the top of the room it is mounted in. The upper air in the room that passes through the UV rays via convection currents or forced air circulation is then sanitized. Bacteria and viruses present in the air that passes through the UV rays produced by the fixture are destroyed. The air in the room is constantly being purified as it flows through the UV rays being produced by the fixture. The IND-AH-UVC-LF-24-SF-WLM-120V is capable of disinfecting the air within an area nine feet wide and 16.25 feet long from the front of the unit. Construction: The enclosure of the IND-AH-UVC-LF-24-SF-WLM-120V is built from 304 stainless steel. A series of front mounted louvers protects people from harmful UV light as well as maximizing the amount of UV rays that are projected across the upper air of the room. A parabolic reflectors with specular aluminum inserts directs as much light from the bulb out of the unit as possible. Mounting: The IND-AH-UVC-LF-24-SF-WLM-120V is designed to be wall mounted. Four mounting holes on the back of the enclosure allow for mounting to a flat and level vertical surface. The minimum mounting height is seven feet from the bottom of the unit to the floor. The mounting surface must be able to support 16 lb of weight. Note on Environment: Sunlight and visible light fixtures do not impact the effectiveness of the disinfecting on this UVC sanitation product. Metal halide, high pressure sodium, fluorescent, and LED light fixtures can be left on. The UV radiation emitted from this product is not disrupted by any type of lighting in the environment. Put simply, NO it DOES NOT need to be dark in the area you plan to disinfect. The UV radiation is harmful to the eyes and skin, and that is why you should not be in the area while it is in operation. Please see user manual for additional safety information. Applications: This ultraviolet indirect UV air disinfection unit can be used to continuously disinfect air of mold, allergens, airborne bacteria, viruses, and germs. The IND-AH-UVC-LF-24-SF-WLM-120V is ideal for use in restaurants, hospitals, clinics, laboratories, nursing homes, schools, food processing facilities, office buildings, conference rooms, universities, clean rooms, and many more. Larson Electronics is a manufacturer and as such can build stationary and portable transformer systems to your specifications. Although we carry several models of power distribution transformer systems, we can deliver custom ordered units almost as quickly as our prebuilt units. If this model does not meet your needs, please contact us at 1-800-369-6671 or to discuss your specific requirements.

Shipping and delivery Information

The PuriLite Peace of Mind 30-day money back guarantee

Payment

American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Su información de pago se procesa de forma segura. No almacenamos los detalles de la tarjeta de crédito ni tenemos acceso a la información de su tarjeta de crédito.

You may also like

Recently viewed