The PDUMNH20HVAT 3.3/3.8kW Single-Phase 208/240V ATS/Monitored PDU provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIA-standard 19-inch racks and features one L6-20R outlet-perfect for connecting a single device or a 0U 208/240V PDU with an L6-20P plug.
Dual 10-foot input cords with L6-20P plugs connect to separate primary and secondary single-phase power sources. The PDU constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1-5 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption.
The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities, including temperature and humidity conditions. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. DHCP/Manual configuration lets you assign network settings to the card automatically, reducing the need for manual configuration. Automated alerts help prevent accidental overloads, power loss and downtime.
Features
  • Two single-phase L6-20P inputs with 10 ft. cords
  • L6-20R outlet for connecting single device or 0U vertical PDU
  • Automatic transfer switching within 1-5 ms
  • Built-in LX Platform Interface for remote access
  • Digital display for real-time status monitoring
Limited Warranty 2 Year
Package Contents
  • PDUMNH20HVAT 1-Outlet PDU
  • Mounting brackets
  • Owner's manual
Environmentally Friendly Yes
Environmental Certification RoHS
Input Voltage 230 V AC
Output Voltage 230 V AC
Input Current 20 A
Power Rating (Watt) 3.80 kW
Weight (Approximate) 6.97 kg
Mount Type Rack-mountable
Rack Height 1U
Height 1.72" (43.69 mm)
Width 16.93" (430.02 mm)
Depth 14" (355.60 mm)
Mounting Orientation Horizontal
Plug/Connector Type NEMA L6-20P
Receptacle Type NEMA L6-20R
Receptacle Detail 1 x NEMA L6-20R
Plug/Connector Detail 2 x NEMA L6-20P
Product Type PDU
Manufacturer Part Number PDUMNH20HVAT
Manufacturer Website Address http://www.tripplite.com
Marketing Information The PDUMNH20HVAT 3.3/3.8kW Single-Phase 208/240V ATS/Monitored PDU provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIA-standard 19-inch racks and features one L6-20R outlet-perfect for connecting a single device or a 0U 208/240V PDU with an L6-20P plug.
Dual 10-foot input cords with L6-20P plugs connect to separate primary and secondary single-phase power sources. The PDU constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1-5 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption.
The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities, including temperature and humidity conditions. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. DHCP/Manual configuration lets you assign network settings to the card automatically, reducing the need for manual configuration. Automated alerts help prevent accidental overloads, power loss and downtime.
Manufacturer Tripp Lite
Product Model PDUMNH20HVAT
Product Name PDUMNH20HVAT 1-Outlet PDU
Brand Name Tripp Lite

Shipping and delivery Information

The PuriLite Peace of Mind 30-day money back guarantee

Payment

American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Vos informations de paiement sont gérées de manière sécurisée. Nous ne stockons ni ne pouvons récupérer votre numéro de carte bancaire.

You may also like

Recently viewed